GSD i70 User manual

4
5
6
5
6
4
Menu Operation
Viewing Open Zones
Stopping an Alarm
Alarm System - Unset
Alarm System - Set
Alarm System - Part Set
Contents
Faults 8
12
Reading the Event Log
11
Manage Users
Allowing Installer Access 12
Viewing Areas 10
Inhibiting Zones 10
YOUR SECURITY IS OUR PRIORITY
User Manual V1.03
Global Security Devices Ltd: No.3 Broomhill Business Complex, Tallaght,
www.globalsecurity.ie
Grade 2 Wireless Intruder Alarm System
i70

3 DEF2 ABC1
6 MNO5 JKL4 GHI
9 DEF8 DEF7 PQRS
#0
*
soft keys relating to
on screen menu
navigation and ok keys
alpha numeric keypad
LED Status:
Green LED: Solid = Battery fully charged, Flashing = Battery charging
Amber LED: Fault Indication
Red LED: Alarm Indication
Blue LED: Solid = Full Set, Flashing = Part Set or some Areas Set
Keypad functions User menu - Quick reference
2 Operation Instructions 3
Operation Instructions

1.
2.
3.
4.
If the display is blank press a key to wake the keypad.
Enter the user code.
- The keypad displays the current state of the system
- If the keypad displays faults, see section Faults
Press OK or wait 5 seconds.
- The system starts settings
- If there are open zones, setting may be prevented. Close the open zones
and try setting again.
- If there are faults, setting may be prevented, see section Faults
Leave the building via the designated exit route.
A.
1.
2.
3.
B.
1.
2.
Part setting with Part Set Soft Key
If the display is blank press a key to wake the keypad.
Enter the user code.
- The keypad displays the current state of the system
- If the right soft key is the part set name, e.g. Night, then part set this way.
- If the keypad displays faults, see section Faults
Press the right soft key.
- The system part sets.
Part setting with Menu Set Soft Key
If the display is blank press a key to wake the keypad.
Enter the user code.
- The keypad displays the current state of the system
3.
4.
5.
- If the right soft key is Menu then part set this way.
- If the keypad displays faults, see section Faults
Press the right soft key.
- The keypad starts the user menu.
Press OK to select the Set/Unset menu.
Use Up/Down to select the part set required and press OK.
- The system part sets.
Setting the alarm system
4 Operation Instructions 5
Operation Instructions
Part setting the alarm system 1.
2.
3.
If the display is blank press a key to wake the keypad.
Enter the user code.
- The keypad displays the current state of the system
Press OK or wait 5 seconds.
- The system unsets
Unsetting the alarm system
1.
2.
3.
Enter the user code.
- The system stops the alarm and unsets.
- The keypad displays a list of recent events.
Use Up/Down to explore the list and find the cause of the alarm.
Use OK if you want to view the details of an event.
Stopping an alarm

1.
2.
3.
4.
If the display is blank press a key to wake the keypad.
Press the Down key.
Press the Down key again.
- The keypad displays a list of open zones.
Use the Down/Up keys to navigate through the list.
OK toggle the setting between On and Off
On activating the menu item using the OK key the keypad displays an edit
window. You can edit the value using the following keys.
1enter punctuation characters using multi-tap text entry or press
and hold to enter digit 1
2 - 9 enter characters using multi-tap text entry or press and hold to
enter digits 2 - 9
0enter digit zero
*cycle character entry between ALL UPPER CASE, First Upper Case
and all lower case
#enter a space
Delete delete one character to the right of the cursor or press and hold
to delete several characters
Left move the cursor one character left or press and hold to move the
cursor several characters
Right move the cursor one character right or press and hold to move
the cursor several characters
Cancel cancel the change and revert to the unchanged text
OK store the new text
Changing an On/Off setting
Changing a name
Viewing open zones
6 Operation Instructions 7
Operation Instructions
Starting the user menu
The user menu gives access to a wide range of functions for users that are
required for more advanced alarm system operation.If the display is blank press
a key to wake the keypad.
1.
2.
Navigation
Enter the user code.
- If the keypad displays faults, see section Faults
- The keypad displays current state.
- If the right soft key is not Menu the installer must first enable the menu
option for your user code.
Press the right soft key, Menu.
- The keypad starts the user menu.
These navigation keys can be used in the user menu, the faults display and
any other similar displays.
Up/Down move in the current menu
OK or Right activate the current menu item, e.g. enter a sub-menu,
change a value
Back or Left back up one menu level
Info display help for the current menu item
Menu operation

6.
7.
8.
Override the condition by pressing the Override soft key.
- The keypad removes it from the conditions preventing it from setting
Repeat the steps 5 & 6 until all conditions are overridden.
- The keypad displays a list warning about the overridden conditions.
Press the Set soft key to continue to set the system.
- The system starts setting.
8 Operation Instructions 9
Operation Instructions
Viewing fault indications
1.
2.
3.
4.
5.
Setting the system with faults
If you try to set, when faults are present the system will prevent you from setting.
This ensures that you are aware of the faults. You should inform your system
installer about the faults so that they can be rectified. If you need to set the
system in spite of the faults you should follow this procedure.
WARNING: when setting with faults present, the system may not be fully
operational, so it may be providing less than its normal level of security.
1.
2.
3.
4.
5.
If the display is blank press a key to wake the keypad.
Enter the user code.
- The keypad will indicate faults if any have occurred
- If no faults have occurred it will show the system state
Explore the fault indications using the menu navigation keys.
- You may need to inform the installer so that faults can be fixed.
Move back up to the top level of the faults display.
Press the Continue soft key.
- This removes from the fault list faults that are no longer present, so that
they will not be displayed next time.
If the display is blank press a key to wake the keypad.
Enter the user code.
- The keypad indicates faults that have occurred.
Press the Continue soft key.
- The keypad displays the current state of the system
Press OK or wait 5 seconds.
- The keypad displays conditions preventing it from setting
Select a condition to override using Up/Down.
Faults

This allows you to set the system without setting one or several zones. Note that
the normal way to part set the system is listed in section Part setting the alarm
system.
1.
2.
3.
4.
5.
6.
7.
8.
9.
Start the user menu (see Menu Operation).
Go into Inhibit zones using the Down and OK keys.
Use Up/Down and OK to select which zones are to be inhibited.
Select a zone to inhibit using the Down and Up keys
Switch on inhibit for the zone by pressing OK.
Go back to the main menu by pressing the Back soft key twice.
Go into Set/Unset using the Up and OK keys.
Use Up/Down to choose the set type and press OK.
- The system warns you that the zones are inhibited.
Press the Set soft key to start setting.
- The system starts setting.
Adding a user
1.
2.
3.
4.
5.
Deleting a user
1.
2.
3.
4.
Setting user codes and allowed operations
1.
2.
3.
Start the user menu (see Menu Operation).
Navigate to Users - Add user and then press OK.
Select the user to add and press OK.
Enter the new code for the user and press OK.
Re-enter the same new code for the user to confirm and press OK.
Start the user menu (see Menu Operation).
Navigate to Users - Delete user and then press OK.
Select the user to delete and press OK.
Select Yes to confirm and press OK.
Start the user menu (see Menu Operation).
Navigate to Users - <user-to-change> and then press OK.
Change the user's Name, Code, Accessible Areas and Permissions as
required.
Inhibiting zones
10 Operation Instructions 11
Operation Instructions
1.
2.
Start the user menu (see Menu Operation).
Use Up/Down and OK to select View areas.
- The system displays a list of areas with icons indicating their state.
- Empty house = unset
- Full house = set
- Half-full house = part set
Viewing areas
Manage users

The event log contains a wide variety of events that occur on the system,
including alarms, faults and set/unset events.
1.
2.
Start the user menu (see Menu Operation).
Navigate to Tools - View event log and press OK.
- Events are listed with the latest at the top.
- Use Up/Down to move through the list.
- Use OK to examine an event in more detail.
A walk test tests that all of the sensors are functioning and communicating
alarms to the system correctly.
1.
2.
3.
4.
5.
In the user menu navigate to Tools - Walk test and then press OK.
Select the area to test and press Next.
Start the walk test: press Next.
- The area switches to walk test mode.
- The keypad displays a list of zones still to be tested.
Walk test: walk around the system tripping each sensor and checking that
it chimes the keypad (or other selected output).
- As each zone is tested the keypad removes it from the list of zones still to
be tested.
- On testing the last zone the keypad beeps and displays a success status.
Press Next or Finish to end the walk test.
The system allows you to stop the installer accessing the system without your
permission.
Enable installer access
1.
2.
Disable installer access
1.
2.
Start the user menu (see Menu Operation).
Navigate to Tools - Enable installer code and press OK.
- If the menu displays Disable installer code then the installer code is already
enabled.
Start the user menu (see Menu Operation).
Navigate to Tools - Disable installer code and press OK.
- If the menu displays Enable installer code then the installer code is already
disabled.
Reading the event log
12 Operation Instructions 13
Operation Instructions
Walk testing
Allowing installer access

14 User Notes 15
User Notes
Notes Notes
Other manuals for i70
6
Table of contents
Other GSD Security System manuals