20 GENERAL CALEA ASSEMBLY INSTRUCTIONS
CALEA lighting plan with FKS4
This product
contains a light
source of energy
efciency class „F“
Alternatively: FKS4-60, 12 V-DC (white plug), 60 watt, 230 V
FKS4-60W with 60-watt transformer „FKS4-60“
EVG LED, 10-way distributor, 12 V-DC (white plug), 30 watt, 230 V
length 5 m, with manual switch and flat Euro plug „LEVG30“
„LEDSET1“ for wall panels
2x LED glass edge strip 85 cm
8.2 watt, 2 m supply cable
LED „LST2“ recessed light
2.6 watt, 2 m supply cable
12 V-DC (white plug)
LED extension,
2 m only if required
LED extension,
2 m only if required
LED extension,
2 m only if required
LED 6-way distributor
LED 6-way distributor
LED electrical storage
compartment with radio
remote control „FKS4“
(4- channel) Dimmable
up to max. 30 watt only if
requested by the customer
On-site
socket
4 pcs, 6-way
distributor,
max. 24 lights, max.
30 watt
when using LEVG30
max. 60 watt
LED glass shelf lighting 410 mm „LG45“
1,9 watt, 2 m supply cable
LED glass shelf lighting 258 mm „LG30“
1,1 watt, 2 m supply cable
LED glass shelf lighting
560 mm „LG60“ 2,8 watt,
2 m supply cable
„LEDSET2“ 2x L. 121 cm, 2x L.17 cm= 15.2 watt, 1x 6-way distributor;
„LEDSET3“ 2x L. 151 cm, 2x L.17 cm= 18.4 watt, 1x 6-way distributor;
„LEDSET4“ 2x L. 211 cm, 2x L.17 cm= 24.8 watt, 1x 6-way distributor;
„LEDSET5“ 2x L. 211 cm, 2x L.105 cm, 2x L.17 cm= 36.2 watt, 1x 6-way distributor;
LED glass edge strip „LN225“ / „LN210“ / „LN195“ / „LN180“
L. 2200 mm / 2050 mm / 1900 mm / 1750 mm, 10.6 watt / 9.8 watt / 9 watt / 8.4 watt
LED glass edge strip „LN165“ / „LN150“ / „LN135“ / „LN120“
L. 1600 mm / 1450 mm / 1300 mm / 1150 mm, 7.7 watt / 7 watt / 6.2 watt / 5 watt
LED glass edge strip „LN105“ / „LN90“ / „LN75“ / „LN60“
L. 1000 mm / 850 mm / 700 mm / 550 mm, 4.8 watt / 4.1 watt / 3.4 watt / 2.6 watt
LED spotlight „LST4“ for shelf
1.4 watt, 2 m supply cable
LED sets for H1 cabinets
Self-adhesive LED profile „Q-Line Mini opal“
Test the lighting! If necessary, check plug connections. Push plug in completely.
Caution, Note the maximum transformer
load. Overloading the transformer reduces
its service life. Fault!
Important information about LED lighting:
Only connect the lights to the safety transformers
in accordance with EN 61558 (VDE 570) using
12-volt direct current (DC).