Hafele DT 750 User manual

HDE 06/2019 732.29.501 ZN 6.167.001.90b.
DT 750
DT 750 BLE
Installation and maintenance instructions - English....2
ins-srce-732.29.501_en.book Seite 1 Montag, 3. Juni 2019 11:53 11

HDE 06/2019 732.29.501
2
Table of contents
1. Notes on these instructions ................................................................... 3
1.1 Contents and target group of these instructions ................................... 3
1.2 Obligations of the installer ..................................................................... 3
1.3 Obligations of the operator .................................................................... 3
1.4 Exclusion of liability ............................................................................... 3
2. Security ................................................................................................. 3
2.1 Safety notes and symbols in these instructions .................................... 3
2.2 Correct purpose of use ......................................................................... 5
2.3 Incorrect purpose of use ....................................................................... 5
2.4 Safety symbols ...................................................................................... 5
2.5 Obligations of the operator .................................................................... 5
2.6 Personnel requirements ........................................................................ 6
2.7 Environmental protection ...................................................................... 7
3. Safety notes and dangers ..................................................................... 8
4. Installation requirements ....................................................................... 8
4.1 Ambient conditions ................................................................................ 8
4.2 Installation conditions ............................................................................ 9
5. Check scope of delivery ...................................................................... 10
6. Installation ........................................................................................... 10
6.1 Safety instructions for installation ....................................................... 10
6.2 Installation description ........................................................................ 10
6.3 Function test ....................................................................................... 10
6.4 Maintenance instructions ..................................................................... 11
7. Approval according to Part 15 of the FCC rules ................................. 12
8. Conformité selon Section 15 de la réglementation de la FCC ............ 13
ins-srce-732.29.501_en.book Seite 2 Montag, 3. Juni 2019 11:53 11

HDE 06/2019 732.29.501
3
1. Notes on these instructions
1.1 Contents and target
group of these
instructions
It is essential to pay attention to these installation and maintenance instructions
in order to install the product successfully and safely. Please pay attention to all
of the specified installation steps, instructions and notes!
These installation and maintenance instructions are intended for:
• the operator of the product
• the installer of the product
In addition to these installation and maintenance instructions, both groups of
people must also have read the separate operating instructions before handling
the product.
In case of use in software-controlled systems, separate instructions are enclosed
with the relevant system components.
1.2 Obligations of
the installer
The installer has the following obligations:
• All notes and specifications in the installation and maintenance instructions must
be complied with. The installation steps must not be deviated from or varied.
• Only the supplied original parts must be installed.
• The installation and maintenance instructions must be handed to the operator
after installation has taken place.
1.3 Obligations of
the operator
The operator has the following obligations:
• The installation requirements must be adhered to.
• The product may only be installed and started up by qualified experts
(see Chapter “1.3 Personnel qualifications” in the operating instructions).
• The installation and maintenance instructions must be kept until the product is
disposed of, and handed to the new operator in the event of a change of operator.
1.4 Exclusion
of liability
No liability is accepted for injuries or damage that is attributable to one or more
of the following reasons:
• failure to read and/or follow the instructions
• abuse of the equipment
• omission of the emergency opening facility
• inadequately qualified/instructed personnel
• failure to use original replacement parts
• negligent handling of the product
2. Security
2.1 Safety notes and
symbols in these
instructions
Safety notes
Safety notes in these installation and maintenance instructions follow a uniform
structure. They are introduced by a signal word that indicates the extent of the
hazard. This is followed by the source of the danger and measures to avoid them.
The following risk levels are distinguished:
DANGER
This combination of symbol and signal word indicates an immediately
dangerous situation causing death or serious injury if not avoided.
WARNING
This combination of symbol and signal word indicates a potentially
dangerous situation that may cause death or serious injury if not avoided.
Installation and maintenance instructions - English
ins-srce-732.29.501_en.book Seite 3 Montag, 3. Juni 2019 11:53 11

HDE 06/2019 732.29.501
4
Safety notes in handling indications
Safety notes may relate to certain individual handling indications. Such safety notes
are incorporated into the handling indication as to not interrupt the flow of reading
when carrying out the action. The signal words described above are used.
Example:
1. Loosen screw.
2. Connect lead.
3. Tighten screws.
Special safety notes
To draw attention to special risks, the following symbols are used in the safety notes:
Other markings
The following markings are used in these installation and maintenance instructions
to highlight action instructions, results, lists, references and other elements:
CAUTION
This combination of symbol and signal word indicates a potentially
dangerous situation that may cause minor or light injury if not avoided.
NOTE
The note is used to point out dangerous situations which could lead to
potential property damage/consequential damage to the product or
damage to the environment.
Notes are also used to provide important additional information.
CAUTION
Risk of leads being trapped by the cover
Watch the position of the lead. Close cover carefully.
Warning sign Type of risk
Warning of dangerous electrical voltage
Warning of a hazardous area
This symbol highlights useful tips and recommendations
and information for efficient and problem-free operation.
1.>, 2.>, 3> Step-by-step action instructions
Results of action steps
• Lists without a defined order
[push button] Controls (e.g. push buttons, switches), display
elements (e.g. signal lamps)
ins-srce-732.29.501_en.book Seite 4 Montag, 3. Juni 2019 11:53 11

HDE 06/2019 732.29.501
5
2.2 Correct purpose
of use
Correct purpose of use
The product is a battery operated electronic door fitting for use in hotels, hospitals
and other buildings with frequent changes of room occupant.
The operator must equip the relevant doors with a single profile cylinder for
emergency opening in the event of faults or emergencies.
The product is intended for the following areas of application:
• Use on room doors inside buildings
• Use on doors that comply with the specified installation requirements
Correct purpose of use also includes adhering to the manufacturer's operating,
service and maintenance conditions.
Correct purpose of use also includes observing all specifications contained in these
installation and maintenance instructions.
Any use beyond or other than the correct purpose of use shall be deemed improper
use.
2.3 Incorrect purpose
of use
Any use that is not mentioned in chapter “2.2 Correct purpose of use” is considered
to be improper. The operator is solely responsible for any resulting damage.
It is particularly important to avoid the following:
• Use without emergency opening facility
• Use in vicinity of electromagnetically sensitive devices
• Use in potentially explosive environments
• Use outdoors and in damp environments
• Use in agressive (e.g. salt- or chlorine containing) environment
• Use of defective or damaged components
• Use of non-original parts
• Omitting components during installation
• Changes of the installation order
• Modification to the product
• Repairs to the product
2.4 Safety symbols The following stickers are located on one or more components of the access control
system. They relate to the immediate environment of where they are located.
Crossed-out dustbin
This image indicates that the respective component must not be
disposed of with residential waste.
2.5 Obligations
of the operator
Operator is the person who operates the access control system for commercial or
economic purposes or allows a third party to use the access control system and thus
bears the legal product responsibility for the protection of the user, the personnel, or
third parties during operation.
Operator's obligations
The access control system is commonly used in the commercial sector.
The operator of the access control system is therefore subject to statutory
occupational safety obligations.
In addition to the safety notes in these installation and maintenance instructions,
safety, work safety, and environmental regulations valid for the area of application
of the access control system must be followed.
ins-srce-732.29.501_en.book Seite 5 Montag, 3. Juni 2019 11:53 11

HDE 06/2019 732.29.501
6
Here, in particular:
• The operator must ensure that escape routes and emergency exit doors are
accessible for all people in case of danger.
• The operator must be aware of the applicable occupational safety regulations
and determine other hazards in a hazard assessment that may arise from the
special working conditions at the place of use of the access control system. The
safety regulations must be implemented for the operation of the access control
system in the form of operating instructions.
• During the entire operating time of the access control system, the operator must
verify that the operating instructions created correspond to the current state of
the regulations and, if necessary, adapt them.
• The operator must clearly regulate and specify the responsibilities for
installation, operation, troubleshooting, maintenance, and cleaning.
• The operator must ensure that all persons handling the access control system
have read and understood these installation and maintenance instructions.
In addition, the operator must train the personnel at regular intervals and inform
them about the risks.
Furthermore, the operator is responsible for ensuring that the access control system
is always in perfect technical condition. The following therefore applies:
• The operator must ensure that the maintenance intervals specified in these
installation and maintenance instructions are followed.
• The operator must have all safety devices inspected regularly for function
and completeness.
2.6 Personnel
requirements
These installation and maintenance instructions describe the qualifications listed
below for the personnel for the various work areas:
Qualified electrician
Qualified electricians are capable of working on electrical systems and recognize
potential hazards and avoid them due to their professional training, knowledge,
experience as well as knowledge of pertinent standards and provisions.
Qualified electricians have been specifically trained for the working environment
in which they operate and know the relevant standards and regulations.
NOTE
Warning of abuse
Unauthorized persons can gain access to rooms using the programming and
clearing keys.
> Only personnel who are authorized by the operator may allocate locking
authorizations.
> Take care when allocating locking authorizations to avoid overlapping or
mistakes.
> Keep programming and clearing keys in a safe place and protect from
abuse.
> It must be ensured that the Dialock server and the network are protected
from malware attacks by suitable virus protection programs in order to
rule out manipulation of the offline terminals.
ins-srce-732.29.501_en.book Seite 6 Montag, 3. Juni 2019 11:53 11

HDE 06/2019 732.29.501
7
Essential requirements
Only those persons are authorized as personnel who can be expected to carry out
their work reliably.
Persons whose ability to react is affected by, e.g., drugs, alcohol, or medication are
not permitted to operate the system.
In the selection of personnel, observe appropriate training as well as the applicable
occupation-specific regulations.
Unauthorized persons
2.7 Environmental
protection
The following environmentally hazardous substances are used:
Batteries
Batteries contain toxic heavy metals. They are subject to special waste treatment
and must be handed into municipal collection points or disposed of by a specialist
company.
Electric and electronic components
Electric and electronic components may contain toxic materials. These components
must be collected separately and be deposited at municipal collection points or
disposed of by a specialist company.
WARNING
Danger to life for unauthorized persons due to hazards in the danger
zone and working area.
Unauthorized persons who do not meet the requirements described herein
will not be aware of the occupational hazards. Therefore, unauthorized
persons are subject to risks of serious injury or death.
• Keep unauthorized persons away from the danger zone and working
area.
• When in doubt, approach persons and have them clear the danger
zone and working area.
• Interrupt the work until unauthorized persons have left the danger zone
and working area.
NOTE
Risk to the environment due to improper handling of environmentally
hazardous substances.
Improper handling of environmentally hazardous substances, particularly
improper disposal, can cause significant damage to the environment.
• Always follow the notes below for handling environmentally hazardous
substances and their disposal.
• If environmentally hazardous substances are accidentally released
into the environment, immediately take appropriate action. When in
doubt, notify the appropriate local authority of the damage and check
for appropriate measures to be taken.
ins-srce-732.29.501_en.book Seite 7 Montag, 3. Juni 2019 11:53 11

HDE 06/2019 732.29.501
8
3. Safety notes and dangers
The product has been built in accordance with the latest state of technology and the
recognised technical safety regulations. Nevertheless, danger to persons or
damage to product or other property could occur during installation and use.
4. Installation requirements
4.1 Ambient
conditions
In addition to the ambient conditions specified here, the instructions in the chapter
entitled “2.1 Correct purpose of use” in the operating instructions also apply.
WARNING
Risk of fatality due to lack of emergency opening facility
If the product is installed without an emergency opening facility, it may not be
possible to open the door from the outside in the event of fault. If emergencies
occur inside the room during the fault, rescue work will be hindered.
> The operator must ensure that doors to which this product is fitted have
an emergency opening facility in the event of faults.
> Häfele is not liable for damage that is attributable to failure to install an
emergency opening facility.
WARNING
Risk of fatality due to failures or faults in electromagnetically sensitive
devices
The electromagnetic radiation of the product can cause faults in sensitive parts
(e.g. in medical equipment).
The functionality thereof will be adversely affected.
> Do not place product close to electromagnetically sensitive devices.
> Pay attention to the safety instructions for the electromagnetically
sensitive devices.
> If you have any doubts regarding compatibility, please contact the
manufacturer.
WARNING
Danger in case of improper use
Improper use of the product can result in dangerous situations.
> Never use the product in potentially explosive areas.
> Never use the product under any other than the approved ambient
conditions.
NOTE
The product may be damaged if it is installed under the wrong ambient
conditions
Please note the following with regard to product installation:
> Do not attach to external doors.
> Do not install in damp environments.
> Do not install in the vicinity of electromagnetically sensitive devices.
> Do not install in potentially explosive environments.
ins-srce-732.29.501_en.book Seite 8 Montag, 3. Juni 2019 11:53 11

HDE 06/2019 732.29.501
9
4.2 Installation
conditions
Door leaf
• Possible door leaf thicknesses: 1¾“ - 3¾“ (45 - 95 mm)
• Possible door materials: Wood and wood material
mortice
• The mortise must be present, and must comply with the dimensioned drawing
“Installation requirements” on page 16.
Suitable single profile cylinder for emergency opening
• The single profile cylinder for emergency opening is not included in the scope
of delivery and must be ordered separately by the operator.
• The size of the single profile cylinder depends on the door leaf thickness.
• For help in calculating the length, see figure 8 on page 22.
NOTE
The product can be damaged by condensed water on cold components
> Before installation, please ensure that all product components are at the
ambient temperature.
> Store products at the installation site for an appropriate period prior to
installation.
NOTE
Installation on metal doors is generally possible. However, the metal
surroundings (doors, frames, etc.) may have an adverse effect on the terminal
function. We therefore recommend a sample installation.
NOTE
The product may be damaged if the single profile cylinder is used
incorrectly
The single profile cylinder is for emergency opening only.
> Do not use the single profile cylinder for normal door locking / unlocking.
NOTE
Only use the specified lever handles. Otherwise, approval as well as liability
and warranty claims will be invalidated.
ins-srce-732.29.501_en.book Seite 9 Montag, 3. Juni 2019 11:53 11

HDE 06/2019 732.29.501
10
5. Check scope of delivery
• Check completeness and condition of scope of delivery prior to installation.
• If parts are missing or damaged, contact the manufacturer.
• Dispose of packaging materials in accordance with national regulations.
6. Installation
6.1 Safety instructions
for installation
6.2 Installation
description
The installation is described in pictures.
6.3 Function test After completing installation, perform a manual function test.
Push the lever handle at the inside of the door:
Correct result:
• Latch bolt is pulled back (escape function).
• Door can always be opened.
Push the lever handle at the outside of the door:
Correct result:
• The lever handle is blocked. The door cannot be opened.
If this is not the case, check the individual installation steps.
WARNING
Risk of suffocation from small parts and packing materials
Screws, small parts and packaging materials can be be deadly playthings
for children.
> Do not leave the packing materials and the contents lying around
carelessly, and keep away from children and babies.
> Keep children away from the installation site during installation.
For overview of scope of delivery, see illustrations starting
on page 15.
NOTE
In the case of fire resistant doors, it is essential to ensure that the drill hole of
the profile cylinder is closed (otherwise flames will penetrate).
Only a profile cylinder (for emergency opening) or blind cylinder with fire
protection approval must be used.
NOTE
Damage to product due to incorrect installation
> Adhere to installation requirements.
> Do not trap or damage wires during installation.
> Never start up and use the product if any wires have been damaged.
> Always drill holes in the door leaf from both sides to prevent pieces
of the door from breaking away.
For step-by-step installation instructions, see picture section
starting on page 15.
ins-srce-732.29.501_en.book Seite 10 Montag, 3. Juni 2019 11:53 11

HDE 06/2019 732.29.501
11
6.4 Maintenance
instructions
In order to ensure that the equipment is usable in accordance with this document,
the following routine maintenance checks must be carried out at intervals of no more
than one month:
• Inspection and actuation of the panic exit device in order to ensure that all
components of the lock are in a satisfactory operating condition.
• The actuation force for releasing the panic exit device must be measured using
a dynamometer and recorded.
• It must be ensured that the locking counterpieces (striking plates) are not blocked
or clogged up.
• It must be checked whether the panic exit device has been greased in
accordance with the manufacturer’s instructions.
• It must be checked that no additional locking devices have been attached to the
door.
• It must be checked at regular intervals whether all components of the system still
correspond with the list of permissible components that were originally delivered
with the system.
• It must be checked at regular intervals whether the operating element has been
correctly tightened, and the actuation force for releasing the panic exit device
must be measured using a dynamometer. It must be checked whether the
actuation force has undergone a major change in comparison with the operating
force recorded during the initial installation.
NOTE
Malfunction due to outdated Dialock firmware.
To ensure that the current Dialock firmware is running on the terminal, the
device has to be flashed (programmed) using the mobile programming unit
(MDU) during start-up. In case of questions concerning the firmware
version or the procedure please contact Häfele.
BLE = Bluetooth Low Energy
Products that are equipped with BLE can also be operated via
smartphone (Android/IOS) with a suitable app. In case of
questions concerning smartphone applications please contact
Häfele.
ins-srce-732.29.501_en.book Seite 11 Montag, 3. Juni 2019 11:53 11

HDE 06/2019 732.29.501
12
7. Approval according to Part 15 of the FCC rules
NOTE: This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference in
a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
• Consult the dealer or an experienced radio / TV technician for help.
NOTICE
This device complies with Part 15 of the FCC Rules [and with Industry
Canada licence-exempt RSS standard(s)].
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including
interference that may cause undesired operation.
NOTICE
Changes or modifications made to this equipment not expressly approved
by Häfele may void the FCC authorization to operate this equipment.
NOTE
Le présent appareil est conforme aux CNR d'Industrie Canada
applicables aux appareils radio exempts de licence. L'exploitation
est autorisée aux deux conditions suivantes:
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'appareil doit accepter tout brouillage radioélectrique subi, même
si le brouillage est susceptible d'en compromettre le fonctionnement.
ins-srce-732.29.501_en.book Seite 12 Montag, 3. Juni 2019 11:53 11

HDE 06/2019 732.29.501
13
8. Conformité selon Section 15 de la réglementation de la FCC
REMARQUE : Cet appareil a été testé et entre dans la catégorie des appareils
numériques de Classe B, selon la Section 15 de la réglementation de la FCC.
Ces limites ont été conçues pour apporter une protection raisonnable aux
installations domestiques contre les interférences néfastes. Cet appareil génère,
utilise et émet de l'énergie sous forme de fréquences radio et, en cas de non-respect
des instructions d'installation et d'utilisation, risque de provoquer des interférences
radio nuisibles. Il n'existe aucune garantie que les interférences ne se produiront
pas dans une installation particulière. Si cet appareil cause des interférences radio
ou télévisuelles nuisibles, pouvant être vérifiées en allumant, puis en éteignant
l'équipement, l'utilisateur est invité à essayer de résoudre le problème de l'une
des façons suivantes :
• Réorienter ou déplacer l'antenne de réception.
• Éloigner l'appareil du poste de réception.
• Brancher l'appareil sur une prise électrique appartenant à un circuit différent
de celui du récepteur.
• Demander de l'aide auprès du revendeur ou d'un technicien radio/TV
expérimenté.
NOTE
Cet appareil est conforme à la Section 15 de la réglementation de la
FCC [et aux CNR d'Industrie Canada applicables aux appareils radio
exempts de licence].
L'exploitation est autorisée aux deux conditions suivantes :
(1) l'appareil ne doit pas produire d’interférences nuisibles, et
(2) l'appareil doit accepter toute interférence subie, même les interférences
susceptibles de compromettre le fonctionnement.
NOTE
Les modifications ou changements effectués sur cet appareil, sans
l’approbation expresse de Häfele, peuvent annuler l’autorisation FCC
d’exploitation de cet appareil.
NOTE
Le présent appareil est conforme aux CNR d'Industrie Canada
applicables aux appareils radio exempts de licence. L'exploitation
est autorisée aux deux conditions suivantes:
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'appareil doit accepter tout brouillage radioélectrique subi, même
si le brouillage est susceptible d'en compromettre le fonctionnement.
ins-srce-732.29.501_en.book Seite 13 Montag, 3. Juni 2019 11:53 11

HDE 06/2019 732.29.501
14
ins-srce-732.29.501_en.book Seite 14 Montag, 3. Juni 2019 11:53 11

HDE 06/2019 732.29.501
15
„mm“
B
F
L
K
H
I
E
C
DG
Q
P
A
J
J
J
X
Z
Y
KL
N
O
4x
2x
M
2x
I
Index Description Index Description
A Interior Module N Plate for Square Spindle
B Battery Cover O Mounting Screw Interior Modul
C Screw Cover P Forend Screw
D Battery Compartment Screw Q Forend Plate
E Mortise Lock Cabel R Drill Sleeve
F Mortise Lock S Drill D13
G Antenna Cabel T Drill D9
H Exterior Module U Drill Template
I Lever Handle V Cylinder
J Grub Screw W Batteries
K Square Spindle X Strike Plate
L Spring for Square Spindle Y Strike Plate Box
M Mounting Screw for Mortise Z Paper Drill Template
Lieferumfang
ins-srce-732.29.501_en.book Seite 15 Montag, 3. Juni 2019 11:53 11

HDE 06/2019 732.29.501
16
Bohrbild
ins-srce-732.29.501_en.book Seite 16 Montag, 3. Juni 2019 11:53 11

HDE 06/2019 732.29.501
17
„mm“
„inch“
inside
outside
2 ³/“ = inch
(69.85) = mm
1¼“
(48)
(120.65)
(63.1)
(31.75)
1.88“ 2.48“
7¹/“
(184)
(203.2)
8“
(25.4)
1“
4³/“
ins-srce-732.29.501_en.book Seite 17 Montag, 3. Juni 2019 11:53 11

HDE 06/2019 732.29.501
18
„mm“
„inch“
2 ³/ = inch
(69.85) = mm
(28.58)
1¹/“
(88.9)
3¹/“
(31.75)
1¹/ “
(123.5)
4⁷/“
(3.2)
¹/“
(7.14)
⁹/“
(12.7)
¹/“
(25.4)
1“
ins-srce-732.29.501_en.book Seite 18 Montag, 3. Juni 2019 11:53 11

HDE 06/2019 732.29.501
19
1
1
2
F
E
M
2
1
1
2
2
3
U
ins-srce-732.29.501_en.book Seite 19 Montag, 3. Juni 2019 11:53 11

HDE 06/2019 732.29.501
20
„mm“
3
Ø 9 mm Ø 13 mm
12
R
S/T
Ø 13
T
T
R
S
Ø 9
Ø 13
4
1
1
2
3
2
F
M
U
ins-srce-732.29.501_en.book Seite 20 Montag, 3. Juni 2019 11:53 11
Other manuals for DT 750
1
This manual suits for next models
1
Table of contents
Other Hafele Lock manuals

Hafele
Hafele Axis 231.98.330 User manual

Hafele
Hafele dialock DTSH User manual

Hafele
Hafele DT 400 User manual

Hafele
Hafele DT 700 User manual

Hafele
Hafele Sola User manual

Hafele
Hafele 235.63.300 User manual

Hafele
Hafele 233.47.000 User manual

Hafele
Hafele dialock DT 100 User manual

Hafele
Hafele ER5000 User manual

Hafele
Hafele SAFE-O-TRONIC LS 100 User manual