Safety Information — Misting Device
Install Information
IMPORTANT SAFETY INSTRUCTIONS
When using misting device, basic precautions should always be
practiced including the following.
1. For electrical safety, always use a GFCI outlet to connect the
pump.
2. To protect against electric shock, do not immerse this pump
or its plug and cord in water.
3. Tubing on the ceiling needs to be fully secured away from
moving fan blades.
4. Ensure tube fittings are fully seated to prevent water leakage.
5. Do not run the water line under mats or carpeting, and do not
cover the water line with runners. Arrange the water line
away from room traffic or where it can be tripped over.
1. Tube routing on the wall may need additional clips suitable for
the installation substrate.
2. Only 25 ft. of tubing is included to account for most
installations. If extra tubing is needed it can be purchased at
the Home Depot 1/4 in. OD pressure rated tubing.
3 . To prevent hot water from misting, keep the supply hose
away from direct sunlight.
4. Installation of a multi-outlet hose manifold (sold separately) is
recommended in order to maintain use of the hose spigot for
watering and other needs.
5. A garden hose can be run from the spigot to the pump or
additional 1/4 in. OD pressure rated tubing can be used to
connect the pump to water supply if not in close proximity to
the fan.
6. Install pump at a level above the water spigot or reservoir.
7. Pump must be installed at a vertical distance < 8 ft. from the
fan.
8. Tubing needs to be crimp free. Nothing can be put on top of
the tubing, which can cause damage or prevent water flow.
Do not route in a way that tubing can be stepped on.
9. If direct connection is not available, water may be drawn from
a reservoir (not included) and an in-line filter, sold separately,
is needed to prevent particulate from entering pump and/or
clogging the nozzles.
9-1 To prevent algae or mold from entering the system, the
reservoir needs to be drained between uses. It is also
recommended the water line is drained as well.
Do not install or use within 10 ft. of a pool.
Do not use an extension cord.
READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
SAVE THESE INSTRUCTIONS.
WARNING: Risk of Electric Shock. When used outdoors,
connect pump power supply only to a covered Class A GFCI
protected receptacle that is weatherproof with the power unit
connected to the receptable. If one is not provided, contact a
qualified electrician for proper installation. Ensure that the
power unit and cord do not interfere with completely closing
the receptacle cover.
WARNING: Risk of Fire. Installtion of a covered Class A GFCI
protected receptacle involves special wiring methods to run
wiring through a building structure. Consult a qualified
electrician.
WARNING: Not for use with receptacles that are
weatherproof only when the receptacle is covered (attachment
plug cap not inserted and receptacle cover closed).
15 HAMPTONBAY.COM
Please contact 1-855-HD-HAMPTON for further assistance.