3.4 Installaon:
Before installing anything, check if all parts are available using the parts list at the back
of this manual. For this, please refer to Annex 1 and 2.
1. Determine where and at what height the PowerSpray PompUnit should be in-
stalled. Users that want to spray a soluon at mulple locaons, are advised to
place the PompUnit at a central locaon in the barn. The maximal length of the
pressure line is 100 meter. For the inlet line, the maximum length is 2 meter. We
advise to keep this inlet line as short as possible. It is advised to mount the Pom-
pUnit close to a wall socket, and to place the liquid container at a steady loca-
on. underneath the PompUnit. Dimensions of the PompUnit are shown in An-
nex 6. Mounng examples are can be found at www.hanskamp.nl/en.
Important! The maximal length of the pressure line is 100 meters.
The maximal length of the inlet line is 2 meters.
2. Determine where the SprayUnit should be mounted. The SprayUnit should be
placed in such a way that the sprayed mist will travel in the direcon of the
nose of the cow that is eang out of the feed trough (g. 6). To ensure this,
the SprayUnit should be mounted into the feed trough. For this, drill a 13mm
hole in the trough, together with two 4mm holes to mount the metal plate.
The plate can be used to mark holes, in case the backside of the trough allows
for limited access. Place the spray nozzle in into the hole, and connect it to the
SprayUnit on the other side of the trough (g. 7). Use the supplied mounng
equipment to secure the SprayUnit ghtly to the trough.
3. Make sure the power to the control unit is shut down. For this, please refer to
the corresponding manual.
4. Connect the other end of the cable to the next available feed type slot of the
feed system. In case of using a SprayUnit without control PCB, the duraon of
the feed signal that is sent by the feed system, should be 0.5 seconds (+/- 0.1).
This duraon corresponds with the spraying duraon. Please refer to the cor-
responding manual for the necessary informaon needed to execute this step.
Important!
Make sure the wiring is properly secured, and out of reach of animals. Other-
wise, this can result to dangerous situaons.
Danger! The PowerSpray is now under electrical voltage!
5. Connect one end of the line to the SprayUnit. It will need to be disconnected
later. The installaon does not need to be re-enclosed, yet. Lead the line back
to the PompUnit. Make sure the line is properly secured, without ght bends,
and without contact with sharp edges, as this prevents blockings and/or leak-
age of the line. As soon as the line is mounted correctly, the line can be cut to the
right length, before pushing it into the le push-in coupling of the PompUnit.
6. Drill an hole (Ø 4mm) in the lid of the liquid container. Plug in the one end of the
remaining line into the container, so that it touches the boom. Cut the line to
the right length, before pushing it into the ingoing push-in coupling of the
PompUnit.
7
6