Calibraon
9. The PipeFeeder is calibrated by allowing the feeding computer to emit a pulse ten
mes. You then weigh the issued feed, divide this by 10 and enter this value into
the feeding computer. Repeat this procedure every month and also aer changing
the feed type.
End assembly
1. Aer the assembly the PipeFeeder HighSpeed has to be covered by shields. Because
all the dierent situaons, the Installer has to take care of this.
2. When the covers aren’t installed, the machine isn’t safe and doesn’t meet the issued
declaraon of conformity.
3. The mounted protecon shields must sasfy the European standards and guidelines
set.
Important!
The PipeFeeder is only intended for cylindrical concentrate with a
diameter of Ø4 to Ø6 mm. The manufacturer cannot guarantee prop-
er funconing for other shapes or dimensions.
During the installaon of the PipeFeeder ensure the pressure of the
concentrate on the dosing unit is greater than 50kg.
Never insert your hand into the boom of the PipeFeeder when it is
sll in operaon or is connected to the electrical power supply (pic.
4).The size of the exit point is limited by a bar to prevent cuts.
The PipeFeeder HighSpeed should be shielded, so that te dosing sys-
tem is unreachable. This separaon should meet European standards
and guidelines. Without this separaon the PipeFeeder HighSpeed
doesn’t meet the safety requirements of Hanskamp AgroTech. If the
PipeFeeder doesn’t meet the safety requirements, there can not be
derrived any rights.
Maintenance
1. Check the PipeFeeder installaon daily for faults and wear. Do this by means of a
control test on the feed motors. Make sure that the vibraons and noise caused by
the PipeFeeder are reduced as much as possible
2. If the PipeFeeder needs maintenance and is connected to the controls ensure that
the PipeFeeder cannot start unexpectedly. Make sure there is no voltage on the
installaon! To do this plug the power supply o at the control unit of the dosing
motor.
3. It is recommended to have repairs and maintenance carried out by a specialist.
4. To avoid electric shocks or geng trapped in the feed auger never open the hous
ing and don’t remove the shields when the PipeFeeder is sll running.
5. For the safety of all concerned the user/owner of the PipeFeeder should follow the
advice and direcons given in the installaon instrucons. If it is not possible to
follow this it is the responsibility of the user and the manufacturer cannot be held
responsible/liable for any injury or damage to or by the product.
Please note! In case of maintenance make sure to always rst switch o the electricity
of the installaon.