Installation Instructions
The 316 stainless steel multi-adjustable trunnion
bracket ensures accurate and stable aiming in
a high vibration environment in all assembly
positions.
The bracket locates the axis of rotation in the
centre of gravity.
When using the trunnion bracket, ensure that the
mounting surface area is even and flat and has a
greater surface area than the bracket surface.
2.
Position the trunnion bracket on the desired
mounting surface and fasten bolt.
The maximum thickness of the mounting
material is 15mm using the supplied bolt.
1.
The floodlight is suitable for upright or pendant
mounting.
3.
Place the lamp into bracket and adjust aiming
angle.
4.
Once the desired angle is achieved, fasten into
place.
Tighten bolts to 7Nm making sure the order of the
bracket system is followed as illustrated to ensure
no metal-to-metal contact.
5.
Once fastened, plug in and switch on.
15° 15°
A
BCD
Option 1
Using two On/O Switches
+_
(Red)
(Brown)
(White)
HELLA-New Zealand Ltd 3
Wiring Instructions
This LED work lamp is polarity conscious. Reverse polarity will not damage this product but will inhibit
its function. HELLA recommends wire connections be soldered and heat shrink tubing applied to seal
the joint.
To switch the work lamp to Full Output Mode, connect Red (+ve) cable to positive and White (-ve) cable
to negative. To switch the work lamp to Dimmed Output Mode, connect both Red (+ve) and Brown (+ve)
cables to positive and the White (-ve) cable to negative.
All power supply and charging systems must adhere to the DC voltage limits specified. A battery or
accumulator must be connected in series with the DC voltage source.
HELLA recommends that each work lamp be protected by a fuse rated at 5 amperes.
Cable Colour Connect to Power Consumption
White Negative (-) -
Red Full Output Mode (+) 45W
Red & Brown Dimmed Output Mode (+) 20W
If the work lamp is required to switch between Full Output and Dimmed Modes then a headlamp type
switch (such as HELLA P/N 4056) may be used. Use the switch for Full Output Mode (position lamp feed
on switch) and Dimmed Output Mode (headlamp feed which includes position lamp).
Alternatively, a combination of two switches may be used as per schematic below.
Protection against damage due to voltage spikes
This LED work lamp is protected against damage from positive voltage spikes caused by events such as
load dump conditions specified in ISO 7637. This lamp is protected against overvoltage, voltage spikes,
reverse polarity connection and negative voltage spikes.
5A Fuse