●Do not use hot water above 40°C for cleaning the pre-filter.
●Do not operate the air conditioner without the pre-filter.
CAUTION
Never use hot water above 50°C, erosive chemicals or brush to clean the front cover and suction grille because they
will damage the plastic surface.
CAUTIONS
●The installation material must be corrosion proof, especially the air conditioner is installed near the sea or hot spring.
●Do not install air conditioner in the places where there is a possibility of inflammable gas leaks.
●Secure tightly the cabinet with screws to the frame. Otherwise there may be danger of the air conditioner dropping.
●Please keep the recommended installation dimensions. Otherwise waterdrops or malfunction may occur.
CAUTIONS
POWER SOURCE
●Check the capacity of wiring and power outlet. The power outlet should be used exclusively for the air conditioner. Do
not use it with other appliances. Any wiring must follow the national wiring regulation.
●Ground the air conditioner to prevent danger of electric shock.
●Connect the air conditioner with power source securely.
●Use a fuse as below:
RA-08MDF / RA-08MEDF
RA-10MDF / RA-10MEDF
RA-13MDF / RA-13MEDF
Voltage rating
Operatable
Voltage range
50Hz 220V
15A
Circuit Breaker 50Hz 198-242V This appliance must be earth
CAUTION
SLIDE OUT OF UNIT
After slide in the unit, please install a sealer between
the base pan and cabinet to prevent from entering rain
water in case of typhoon. Fasten the unit to cabinet
at the side with the screw, then refit the front cover.
1Remove the four screws which fasten the base pan
to the cabinet at the side and back.
2Remove the stopper at front left side of base.
(RA-13MDF/ RA-13MEDF)
3Slide out the unit by pulling the handles.
DRAIN PAN
Drain Pan edge shall not exceed the cabinet roller.
7RS9LHZ
INSTALLATION WORK INSPECTION CHECK LIST
CAUTION
When using operation of auto swing function, if the vertical deflector swing angle is incomplete, please turn the deflector manually to
the utmost left angle. An abnormal sound will occur when adjusting the vertical deflector. This sound indicates that the engagement of
gear is in position and does not affect the operation.
When raining, rain water will enter the outdoor side. An abnormal sound will occur during operation of unit in raining conditions and
approximately 10 minutes after rain stop. This will not affect the performance or liability of the room air conditioner.
MEMO
.....................................................................................................................................................................................................
.....................................................................................................................................................................................................
.....................................................................................................................................................................................................
Model a
365
395
* Recommended dimension for performance testing purpose only.
b
490
580
c
Over 200
Over 200
d
Over
100
e
Over
1200
f
Over
150
g
Over
900
h
Over
200
i
Over
200
j*
130 or more
160 or more
Dimension (mm)
Recommended temperature range for safety testing should be as below:
Cold side : Dry bulb 21 – 32°C
Wet bulb 15 – 23°C
Hot side : Dry bulb 21 – 43°C
Wet bulb 15 – 26°C
<
IA0000: A
>
Always turn off and unplug the unit before any cleaning or maintenance to ensure safety
CAUTION
PRE-FILTER
If the pre-filter is clogged with dust, the air flow volume will be decreased and resulting in poor cooling performance, and
increased operating noise. Be sure to clean the filter about every 20 days.
1 Remove the suction grille by pulling the bottom corner and slightly lift up the
suction grille.
2 - 3 Pull downward to unhook the suction grille and remove the suction grille.
●Lift and unhook the bottom of the pre-filter and remove it.
●Remove dust from the pre-filter by using a vacuum cleaner. If the pre-filter
is very dirty, wash it with detergent and rinse properly with water. Dry
the pre-filter with soft cloth and do not expose it to heat or under direct
sunlight.
●Install the pre-filter by fitting the top hooks and then hook the bottom of
the pre-filter.
●Attach the suction grille back to its place by hooking at the top side to
the front cover, then gently push at bottom corner.
Clean the front cover and suction grille with a soft dry cloth. When it is excessively dirty, wipe it with a soft cloth dampened
with mild soap, then wipe it again thoroughly with a soft dry cloth.
The suction grille can also be removed and be washed with water and mild soap. Remove the suction grille in the
following manner.
1 Remove the suction grille by pulling the bottom corner
and slightly lift up the suction grille .
2 - 3 Pull downward to unhook the suction grille and remove
the suction grille.
Does not operate at all
Poor cooling performance
Check the following items before asking for service. If the malfunction persists, please contact service centre.
1Is the power cord loosened or unplugged?
2Is the fuse blown out or the circuit breaker tripped?
3Is the voltage normal?
4Is the main switch set to “OFF” position?
1Is the pre-filter covered with heavy dust?
Clean pre-filter and replace it.
2Is the temperature setting correctly?
3Is the sunlight fall directly in the air conditioner?
4Is the air flow on the rear side (outdoor) blocked?
Leave a space of 900 mm (3 feet) behind the rear side of air conditioner.
5The doors or windows may be opened widely or there are other sources of heat in
the room.
6Is the ventilation damper opened?
Symptom Check
If the power supply cord is damaged, it must be replaced by the manufacturer, its service agent or similiarly qualified
persons in order to avoid a hazard.
CAUTION
Remove all the shipping parts before installation and consult an authorised dealer concerning installation requirements,
otherwise may damage the air conditioner.
LOCATION
●Select a location that can support the weight of the air conditioner and will not cause increased operating noise and
vibration.
●Select a location to avoid direct sunlight on the air conditioner.
●Select a good location for efficient air circulation.
●Select a location where there is no obstacles near the air inlet and outlet.
INSTALLATION INSTRUCTIONS
REMOVE THE FRONT COVER
1Remove the rubber plug from the base pan.
2Install the drain pan by using 2 pieces of screws (provided) at the cabinet.
3Connect the drain pan with the drain hose to drain point. (Drain hose or tubing
can be purchase locally. Drain hose inner diameter should be around ø13mm
or 1/2 inch.)
4Pour 2 glasses of water into the drain pan to ensure the drainage is functioning
normal.
5Slide the air conditioner unit back into the cabinet.
CONDENSED WATER DRAINAGE
This air conditioner use a “turbo fan splashing ring” which is designed to splash the condensated water on the condenser
surface for maximum cooling efficiency, thus producing a splashing sound.
If you are uncomfortable with the sound, you can install an outside drainage by using
the following procedure which may, reduce the cooling operation performance.
Have you removed the shipping parts? Please check the caution sheet which is
attached at front cover.
Is the incline of room air conditioner regarding front and rear, right and left all right
after installation?
Is the strength of installation sufficient?
Have you grounded the room air conditioner?
Have you fastened the unit to the cabinet?
Have you done a test operation, and are there any abnormal phenomena?
Item
No.
1
2
3
4
5
6
Check Item Confirm
MAINTENANCE
BEFORE ASKING FOR SERVICE
FRONT COVER AND SUCTION GRILLE
Remove the front cover in the following manner.
1Remove the suction grille by pulling the bottom corner and
slightly lift up the suction grille.
2 - 3 Pull downward to unhook the suction grille and remove
the suction grille.
4Lift and unhook the bottom of the pre-filter and remove it.
5Remove two screws which secure the front cover.
6Remove the front cover from lower side. Disconnect the
timing motor connector at right side of the electrical box.
The Drain Pan can be used in any positions as below and be secured by 2 screws to avoid water dropping problem:
POWER CORD ARRANGEMENT
If power cord is withdrawn from left side of unit, please
arrange the power cord as in figure after installing the
front cover.
20mm or more 20mm or more
RA-08MDF / RA-08MEDF
RA-10MDF / RA-10MEDF
RA-13MDF / RA-13MEDF