Hitachi airHome 800 User manual

SAFETY PRECAUTION
●Read the safety precautions carefully before operating the unit.
●The contents of this section are vital to ensure safety. Please pay special attention to the following sign.
WARNING ........ Incorrect methods of installation may cause death or serious injury.
CAUTION ......... Improper installation may result in serious consequence.
Make sure to connect earth wire.
This sign in the gures indicates prohibition.
Be sure that the unit operates in proper condition after installation. Explain to customer the proper operation
and maintenance of the unit as described in the user’s guide. Ask a customer to keep this installation manual
together with the instruction manual.
Tools Needed For Installation Work
!
!
WARNING
!
●Carefully read through the procedures of
proper installation before starting installation
work.
●The sales agent should inform customers
regarding the correct operation of installation.
(Mark is exclusive use tool for R32)
●+–Screwdriver ●Measuring Tape
●Knife ●Saw ●ø 65mm Power Drill
●Hexagonal Wrench Key ( 4mm)
●Wrench (14,17,19,22mm)
Gas Leakage Detector ●Pipe Cutter
●Putty ●Vinyl Tape ●Pliers
●Flare Tool Vacuum Pump Adaptor
Manifold Valve Charge Hose
Vacuum Pump
●Please request your sales agent or qualied technician to install your unit. Water leakage,
short circuit or re may occur if you do the installation work yourself.
●Please observe the instructions stated in the installation manual during the process of
installation. Improper installation may cause water leakage, electric shock and re.
●Make sure that the units are mounted at locations which are able to provide full support to
the weight of the units. If not, the units may collapse and impose danger.
●Observe the rules and regulations of the electrical installation and the methods described in
the installation manual when dealing with the electrical work. Use cables which are ofcially
approved in your country. Be sure to use the specied circuit. A short circuit and re may
occur due to the use of low quality wire or improper work.
●Be sure to use the specied cables for connecting the indoor and outdoor units. Please
ensure that the connections are tight after the conductors of the wire are inserted into the
terminals to prevent the external force is being applied to the connection section of the
terminal base. Improper insertion and loose contact may cause over-heating and re.
●Please use the specied components for installation work. Otherwise, the units may collapse
or water leakage, electric shock, re or stronger vibration may occur.
●Be sure to use the specied piping set for R32. Otherwise, this may result in broken copper
pipes or faults.
●When installing or transferring an air conditioner to another location, make sure that air
other than the specied refrigerant(R32) does not enter the refrigeration cycle. If other air
should enter, the pressure level of the refrigeration cycle may increase abnormally which
could result in a rupture and injury.
●Be sure to ventilate fully if a refrigerant gas leak while at work. If the refrigerant gas comes
into contact with re, a poisonous gas may occur.
●After completion of installation work, check to make sure that there is no refrigeration gas
leakage. If the refrigerant gas leaks into the room, coming into contact with re in the fan-
driven heater, space heater, etc., a poisonous gas may occur.
●Unauthorized modications to the air conditioner may be dangerous. If a breakdown occurs
please call a qualied air conditioner technician or electrician. Improper repairs may result
in water leakage, electric shock and re, etc.
●Be sure to connect the earth line from the power supply wire to the outdoor unit and between
the outdoor and indoor unit. Do not connect the earth line to the gas tube, water pipe, lighting
rod or the earth line of the telephone unit. Improper earthing may cause electric shocks.
●When nishing the refrigerant collection (pumping down), stop the compressor and then
remove the coolant pipe. If you remove the refrigerant pipe while the compressor is operating
and the service valve is released, air is sucked and a pressure in the freezing cycle system
will build up steeply, causing an explosion or injury.
●When installing the unit, be sure to install the refrigerant pipe before starting the compressor.
If the refrigerant pipe is not installed and the compressor is operated with the service
valve released, air is sucked and the pressure level of the refrigeration cycle may increase
abnormally which could result in a rupture and injury.
●The electric cables should neither be reworked nor added. Make sure to use an exclusive
circuit breaker. Otherwise re or electric shock might occur by connection failure, isolation
failure or over current.
●Make sure to connect cables to terminal properly and terminal cover should close rmly.
Otherwise, over heating at terminal contact, re or electric shock might occur.
●Make sure that there is no dust on any connected points of electric cables and x rmly.
Otherwise, re or electric shock might occur.
CAUTION
!
●A circuit breaker must be installed in the house distribution
box for the direct connected power supply cables to the
outdoor unit. In case of other installations a main switch
with a contact gap or more than 3mm has to be installed.
Without a circuit breaker, the danger of electric shock
exists..
●Do not install the unit near a location where
there is ammable gas. The outdoor unit may
catch re if ammable gas leaks around it.
●Please ensure smooth ow of water when installing the
drain hose. Improper installing may wet your furniture.
●An IEC approved power cord should be used. Power cord
type: NYM.
WARNING
●The unit should be mounted at stable, non-vibratory location which can provide full support to the unit.
CAUTION
●No nearby heat source and no obstruction near the air outlet is allowed.
●The clearance distances from top, right and left are specied in gure below.
●The location must be convenient for water drainage and pipe connection with the Outdoor unit.
●No nearby leakage risk of ammable gas, and no nearby source of vapor or oil smoke.
●To avoid interference from noise, please place the unit and its remote controller at least 1m from the radio and television.
●To avoid any error in signal transmission from the remote controller, please put the controller far away from high-frequency
machines and high-power wireless systems.
●The installation height should be at least 2300 mm or more from the oor.
●The distance from the air outlet to the re alarm must be at least 1500mm and there must be no re alarm in the front
direction of the indoor unit.
The Choice of Mounting Site (Please note the following matters and obtain permission from customer before installation).
WARNING
CAUTION
CAUTION
CAUTION
This symbol shows that this equipment uses a ammable
refrigerant.
If the refrigerant is leaked, together with an external ignition
source, there is a possibility of ignition.
This symbol shows that the Operation Instructions should
be read carefully.
This symbol shows that a service personnel should be
handling this equipment with reference to the Installation
Manual.
This symbol shows that there is information included in
the Operation Manual and/or Installation Manual.
12
Direction of Piping
There are 6 directions
allowed, namely,
backward piping,
backward piping from left,
horizontally piping from
right, horizontally piping
from left, vertically down
from right, vertically down
from left.
Backward piping from left
Connection
above 50mm
about 450mm
2300 or more
above 100mm
above 100mm
must not bend
about 300mm
Be sure to
completely
seal any gap
with putty.
The indoor piping should be
insulated with the enclosed
insulation pipe. (If the insulator
is insufficient, please use
commercial products.)
Installation of Hanger, Wall Penetration and Installation of Protection Pipe
1
CAUTION
!
●The draining of the water container inside the indoor unit can be done from the left. Therefore the hanger
must be xed horizontally or slightly tilted towards the side of drain hose. Otherwise, condensed water
may overow the water container.
Direct Mounting On The Wall
●Please use hidden beams in the wall to hold the hanger.
INDOOR UNIT
Figure showing the Installation of Indoor Unit.
Level
Line Weight Wall hole
Screw for Hanger
Hanger Screw the hanger at the positions
possibly near the upper and lower
hooks where the indoor unit is
hung. Use 4 or more screws to
x the hanger.
Installation of the Indoor Unit
2
Cutting Low Cover bush
1PIPING FROM THE RIGHT SIDE (BACKWARD, DOWNWARD, HORIZONTAL)
●While installing the pipe from the right, left or bottom
side, use a knife to cut openings as shown in gure.
Then smoothen the edges of openings with a le.
Openings
Openings
Preparation
Connecting cords, pipe
and drain hose must
be laid together with
Vinyl tape.
●Connect connecting cord.
●Pull out the pipe, connecting cord and drain hose.
Installation
●Insert the pipe through the wall hole.
1 The upper part of the Indoor unit is hanged on the hanger.
2 The projection at the lower part of the Indoor unit is hooked
onto the hanger
Wall hole
Pipe
Drain hose
Drain layout of backward piping
Cable
Hanger
Refrigerating
pipe
Lift the body of
the unit upwards
and then force it
downwards.
Protection Pipe
Drain Hose Connecting Cord
Hanger
Projection
2PIPING FROM THE LEFT SIDE (BACKWARD, DOWNWARD, HORIZONTAL)
Preparation
Changed of Drain Hose and Installation Procedures
●Exchange the location of drain hose and drain cap while installing the pipe from the left side as shown in below.
Be sure to plug in the drain hose until the insulating material folds upon itself.
●Please use pliers to pull out the drain cap.
(This is an easier way to remove the drain
cap). Insufcient insert may result in water leakage.
!
CAUTION
Pipe
Pipe support
Rubber strap tied
with great force
Transform after
bending downward
1
1
2
1
!
CAUTION



INSTALLATION
MANUAL
<
SIA2377: A
>
Home
800
!
!
42.5mm
Drain Hose
Be sure that the wire is not in contact with any metal in the wall. Please use the protection pipe as wire passing
through the hollow part of the wall so as to prevent the possibility of damaged by mouse. Unless it seals
completely, any air with high humidity flows from outdoor and dew may drop.
Indoor Outdoor
Wall Penetration and Installation of Protection Pipe
●Drill a ø 65mm hole on wall which is slightly tilted towards the outdoor side.
Drill the wall at a small angle.
Cut the protection pipe according to the wall thickness.
Seal with Seal with
putty putty 2-5mm
●
Protection
pipe Sleeve of
protection pipe
!
WARNING
Installation Of Remote Controller
●The remote controller can be placed in its
holder which is fixed on wall or beam.
To operate the remote controller at its holder,
please ensure that the unit can receive signal
transmitted from the controller at the place
where the holder is to be fixed.The unit will
beep when signal is received from the remote
controller. The signal transmission is weaken
by the fluorescent light. Therefore, during the
installation of the remote control holder, please
switch on the light, even during day time, to
determine the mounting location of the holder.
●
4
Plug How to select 1.8kw or 1.2kw
capacity for RAK-XJ18QHAE
58
Remote controller setting to
select 1.8kw or 1.2kw capacity,
please refer to the service
manual for detailed introduction.
3
Names of Indoor Components
No. Item Qty
Hanger
1
1
Screw for Hanger
2
6
AAA size Battery
3
2
Remote Controller
4
1
Screw for Remote
5Controller Holder
2
Air purifying filter
6
2
C-case
7
2
Remote Controller Holder
8
1
Insulation
sheet
Drain cap
●Remove low cover.
●Insert drain cap up to
the location securely
till the cap stops.
●Push the pipe deeply
until the insulating
section of the drain
hose end gets over
the rib at the indoor
unit side.
Drain HoseDrain cap
Empty gap in the sleeve of protection pipe should be completely sealed with putty to avoid dripping of rain water
into the room.
Please ensure smooth flow of water when installing the drain hose. Improper installing may wet your furniture.
●
●
●An IEC approved power cord should be used. Power cord type: NYM.
The remote controller must be slide in
the remote controller holder, in the
direction as shown in the figure, until
it hooks at the lower end of the remote
controller holder.
Remote
Controller
Remote
Controller
Holder
Screw (2 pieces)
Procedures of Installation and Precautions
1. 3. Fix the hanger on wall
●Procedures to fix the hanger.
Drill holes on wall.
(As shown below)
2. Push plug into the holes.
(As shown below) with 4.1 x 32 screw
(As shown in figure below)
Wall
32mm
ø4.8mm
1
2
Hanger
Plug
Wall
(From commercial
product)
Screw
Wall
8Remote
Control
Holder
20mm
5Screw
Plug (From commercial product)
ø4.4mm
Procedures to fix the holder of remote control.
1.Drill holes on wall.(As shown below) 2.Push plug into the holes.
(As shown below)
●The rubber strap used for fixing the insulator should not be tied with great force.
Otherwise, this will damage heat insulation and causes water condensation.
●Please pull the lower part of the indoor unit outwards to check if the unit is hooked
onto the hanger. Improper installation may cause vibration and noise.
●Transform the piping while holding down the lower portion of pipe-support by
hand.
Ceiling
WALL
< SIA2377: A >
SPLIT UNIT AIR CONDITIONER
INDOOR UNIT
RAK-XJ18QHAE
RAK-XJ25RHAE
RAK-XJ35RHAE
RAK-XJ50RHAE
EN INSTRUCTION MANUAL
FOR SERVICE
PERSONNEL ONLY
!
!
!
1
2
Cooling & Heating
WARNING
This symbol shows that this equipment uses a ammable
refrigerant.
If the refrigerant is leaked, together with an external
ignition source, there is a possibility of ignition.
CAUTION
This symbol shows that the Operation Instructions should
be read carefully.
CAUTION
This symbol shows that a service personnel should be
handling this equipment with reference to the Installation
Manual.
CAUTION
This symbol shows that there is information included in
the Operation Manual and/or Installation Manual.
No. Item Qty
Hanger
1
Screw for Hanger
6
AAA size Battery
2
Remote Controller
1
5
Screw for Remote
Controller Holder 2
6
Air purifying lter
2
7C-case
2
8
Remote Controller Holder
1
INSTALLATION
MANUAL
SPLIT UNIT AIR CONDITIONER
INDOOR UNIT
RAK-XJ18QHAE
RAK-XJ25RHAE
RAK-XJ35RHAE
RAK-XJ50RHAE
EN INSTRUCTION MANUAL
FOR SERVICE
PERSONNEL ONLY
● Carefully read through the procedures of
proper installation before starting installation
work.
● The sales agent should inform customers
regarding the correct operation of installation.
Tools Needed For Installation Work
(Mark is exclusive use tool for R32)
● Screwdriver ● Measuring Tape
● Knife ● Saw ● ø 65mm Power Drill
● Hexagonal Wrench Key ( 4mm)
● Wrench (14,17,19,22mm) Gas Leakage
Detector ● Pipe Cutter ● Putty ● Vinyl Tape
● Pliers ● Flare Tool Vacuum Pump
Adaptor Manifold Valve Charge Hose
Vacuum Pump
WARNING
● Please request your sales agent or qualied technician to install your unit. Water leakage, short
circuit or re may occur if you do the installation work yourself.
● Please observe the instructions stated in the installation manual during the process of installation.
Improper installation may cause water leakage, electric shock and re.
● Make sure that the units are mounted at locations which are able to provide full support to the weight
of the units. If not, the units may collapse and impose danger.
● Observe the rules and regulations of the electrical installation and the methods described in the
installation manual when dealing with the electrical work. Use cables which are o󰀩cially approved in
your country. Be sure to use the specied circuit. A short circuit and re may occur due to the use of
low quality wire or improper work.
● Be sure to use the specied cables for connecting the indoor and outdoor units. Please ensure that
the connections are tight after the conductors of the wire are inserted into the terminals to prevent
the external force is being applied to the connection section of the terminal base. Improper insertion
and loose contact may cause over-heating and re.
● Please use the specied components for installation work. Otherwise, the units may collapse or
water leakage, electric shock, re or stronger vibration may occur.
● Be sure to use the specied piping set for R32. Otherwise, this may result in broken copper pipes or
faults.
● When installing or transferring an air conditioner to another location, make sure that air other than
the specied refrigerant(R32) does not enter the refrigeration cycle. If other air should enter, the
pressure level of the refrigeration cycle may increase abnormally which could result in a rupture and
injury.
● Be sure to ventilate fully if a refrigerant gas leak while at work. If the refrigerant gas comes into
contact with re, a poisonous gas may occur.
● After completion of installation work, check to make sure that there is no refrigeration gas leakage.
If the refrigerant gas leaks into the room, coming into contact with re in the fandriven heater, space
heater, etc., a poisonous gas may occur.
● Unauthorized modications to the air conditioner may be dangerous. If a breakdown occurs please
call a qualied air conditioner technician or electrician. Improper repairs may result in water leakage,
electric shock and re, etc.
● Be sure to connect the earth line from the power supply wire to the outdoor unit and between the
outdoor and indoor unit. Do not connect the earth line to the gas tube, water pipe, lighting rod or the
earth line of the telephone unit. Improper earthing may cause electric shocks.
● When nishing the refrigerant collection (pumping down), stop the compressor and then remove the
coolant pipe. If you remove the refrigerant pipe while the compressor is operating and the service
valve is released, air is sucked and a pressure in the freezing cycle system will build up steeply,
causing an explosion or injury.
● When installing the unit, be sure to install the refrigerant pipe before starting the compressor. If the
refrigerant pipe is not installed and the compressor is operated with the service valve released, air is
sucked and the pressure level of the refrigeration cycle may increase abnormally which could result
in a rupture and injury.
● The electric cables should neither be reworked nor added. Make sure to use an exclusive circuit
breaker. Otherwise re or electric shock might occur by connection failure, isolation failure or over
current.
● Make sure to connect cables to terminal properly and terminal cover should close rmly.
Otherwise, over heating at terminal contact, re or electric shock might occur.
● Make sure that there is no dust on any connected points of electric cables and x rmly. Otherwise,
re or electric shock might occur.
SAFETY PRECAUTION
● Read the safety precautions carefully before operating the unit.
● The contents of this section are vital to ensure safety. Please pay special attention to the following sign.
Be sure that the unit operates in proper condition after installation. Explain to customer the proper operation
and maintenance of the unit as described in the user’s guide. Ask a customer to keep this installation manual
together with the instruction manual.
Access the full version of the
User Installation Manual by
scanning the code.
WARNING ...... Incorrect methods of installation may cause death or serious injury.
CAUTION ....... Improper installation may result in serious consequence.
Make sure to connect earth wire.
This sign in the gures indicates prohibition.
The Choice of Mounting Site (Please note the following matters and obtain permission from customer before installation).
● A circuit breaker must be installed in the house distribution
box for the direct connected power supply cables to the
outdoor unit. In case of other installations a main switch
with a contact gap or more than 3mm has to be installed.
Without a circuit breaker, the danger of electric shock
exists.
● Do not install the unit near a location where
there is ammable gas. The outdoor unit may
catch re if ammable gas leaks around it.
● Please ensure smooth ow of water when installing the
drain hose. Improper installing may wet your furniture.
● An IEC approved power cord should be used. Power cord
type: NYM.
!CAUTION
!WARNING
● The unit should be mounted at stable, non-vibratory location which can provide full support to the unit.
!CAUTION
● No nearby heat source and no obstruction near the air outlet is allowed.
● The clearance distances from top, right and left are specied in gure below.
● The location must be convenient for water drainage and pipe connection with the Outdoor unit.
● No nearby leakage risk of ammable gas, and no nearby source of vapor or oil smoke.
● To avoid interference from noise, please place the unit and its remote controller at least 1m from the radio and television.
● To avoid any error in signal transmission from the remote controller, please put the controller far away from high-frequency
machines and high-power wireless systems.
● The installation height should be at least 2300 mm or more from the oor.
● The distance from the air outlet to the re alarm must be at least 1500mm and there must be no re alarm in the front direction
of the indoor unit.
Figure showing the Installation of Indoor Unit.
Be sure to
completely
seal any gap
with putty.
The indoor piping should be
insulated with the enclosed
insulation pipe. (If the insulator
is insu󰀩cient, please use
commercial products.)
Screw the hanger at the positions
possibly near the upper and
lower hooks where the indoor unit
is hung. Use 4 or more screws to
x the hanger.
Direction of Piping
Backward piping from left
Connection
There are 6 directions
allowed, namely,
backward piping,
backward piping from left,
horizontally piping from
right, horizontally piping
from left, vertically down
from right, vertically down
from left.
above 50mm
above 100mm
above 100mm
Names of Indoor Components
about 450mm
about 300mm
must not bend
Insulation
sheet
Plug
2300 or more
How to select 1.8kw or 1.2kw
capacity for RAK-XJ18QHAE
Remote controller setting to
select 1.8kw or 1.2kw capacity,
please refer to the service
manual for detailed introduction.
INDOOR UNIT
Installation of Hanger, Wall Penetration and Installation of Protection Pipe
!CAUTION
● The draining of the water container inside the indoor unit can be done from the left. Therefore the hanger
must be xed horizontally or slightly tilted towards the side of drain hose. Otherwise, condensed water may
overow the water container. !WARNING
Be sure that the wire is not in contact with any metal in the wall. Please use the protection pipe as wire passing
through the hollow part of the wall so as to prevent the possibility of damaged by mouse. Unless it seals
completely, any air with high humidity ows from outdoor and dew may drop.
Direct Mounting On The Wall
● Please use hidden beams in the wall to hold the hanger.
Cutting Low Cover bush
● While installing the pipe from the right, left or bottom
side, use a knife to cut openings as shown in gure.
Then smoothen the edges of openings with a le.
Procedures of Installation and Precautions
● Procedures to x the hanger.
Installation Of Remote Controller
● The remote controller can be placed in its
holder which is xed on wall or beam.
● To operate the remote controller at its holder,
please ensure that the unit can receive signal
transmitted from the controller at the place
where the holder is to be xed.The unit will
beep when signal is received from the remote
controller. The signal transmission is weaken
by the uorescent light. Therefore, during the
installation of the remote control holder, please
switch on the light, even during day time, to
determine the mounting location of the holder.
● Push the pipe deeply
until the insulating
section of the drain
hose end gets over
the rib at the indoor
unit side.
● Remove low cover.
● Insert drain cap up to
the location securely
till the cap stops.
Drain cap Drain cap Drain Hose
Wall Penetration and Installation of Protection Pipe
● Drill a ø 65mm hole on wall which is slightly tilted towards the outdoor side.
Drill the wall at a small angle.
● Cut the protection pipe according to the wall thickness.
1. Drill holes on wall.
(As shown below)
2. Push plug into the holes.
(As shown below)
The remote controller must be slide
in the remote controller holder, in the
direction as shown in the gure, until it
hooks at the lower end of the remote
controller holder.
2. Push plug into the holes.
(As shown below)
3. Fix the hanger on wall with
4.1 x 32 screw
(As shown in gure below)
Visible outline of
the indoor unit 660mm
15mm
115mm
42.5mm
294mm
36mm
67mm
950mm
20mm
Drain Hose
Screw for Hanger
Hanger
Wall hole
Weight
Line
Level
Ø65
Ø65
105mm
145mm 145mm
ø4.8mmø4.4mm
● Procedures to x the holder of remote control.
1.Drill holes on wall.(As shown below)
32mm
Hanger
Ceiling
Openings Openings
Screw
Wall
Plug
(From commercial
product)
Wall
Wall
8Remote
Control
Holder Screw
Plug (From commercial product)
<SIA2377: >
Indoor Outdoor
Seal with
putty Seal with
putty 2-5mm
Protection
pipe WALL
Sleeve of
protection pipe
Remote
Controller
Remote
Controller
Holder
Screw (2 pieces)
● Empty gap in the sleeve of protection pipe should be completely sealed with putty to avoid dripping of rain water into
the room.
● Please ensure smooth ow of water when installing the drain hose. Improper installing may wet your furniture.
● An IEC approved power cord should be used. Power cord type: NYM.
Installation of the Indoor Unit
PIPING FROM THE RIGHT SIDE (BACKWARD, DOWNWARD, HORIZONTAL)
PIPING FROM THE LEFT SIDE (BACKWARD, DOWNWARD, HORIZONTAL)
Preparation
● Connect connecting cord.
● Pull out the pipe, connecting cord and drain hose.
Installation
● Insert the pipe through the wall hole.
The upper part of the Indoor unit is hanged on the hanger.
The projection at the lower part of the Indoor unit is hooked
onto the hanger
Preparation
Changed of Drain Hose and Installation Procedures
● Exchange the location of drain hose and drain cap while installing the pipe from the left side as shown in below.
Be sure to plug in the drain hose until the insulating material folds upon itself.
Connecting cords, pipe
and drain hose must be
laid together with Vinyl
tape.
Hanger Hanger
Protection Pipe
Refrigerating
pipe
Lift the body of
the unit upwards
and then force it
downwards.
Connecting Cord Projection
Wall hole
Drain layout of backward piping
Pipe
Drain hose
Cable
Drain Hose
!CAUTION
Insufcient insert may result in water leakage.
● Please use pliers to pull out the drain cap.
(This is an easier way to remove the drain
cap).
!CAUTION
● The rubber strap used for xing the insulator should not be tied with great force.
Otherwise, this will damage heat insulation and causes water condensation.
● Please pull the lower part of the indoor unit outwards to check if the unit is
hooked onto the hanger. Improper installation may cause vibration and noise.
● Transform the piping while holding down the lower portion of pipe-support by
hand. Pipe support
Rubber strap tied
with great force
Transform after
bending downward
Pipe
A
1
2
3
1
2
Move Arm Push
THE CONNECTION OF REFRIGERATING PIPE DURING THE
INSTALLATION OF INDOOR UNIT
Preparation To Install Refrigerating Pipes
● The refrigerating pipes and connecting cord arrangement are attached.
Outer Diameter
mm (inch)
Thickness
(mm)
A (mm)
Flare tool for R32
Clutch type
Conventional are tool
Clutch type Wing nut type
6.35 (1/4") 0.8 0.0 ~ 0.5 1.0 ~ 1.5 1.5 ~ 2.0
9.52 (3/8") 0.8 0.0 ~ 0.5 1.0 ~ 1.5 1.5 ~ 2.0
12.70 (1/2") 0.8 0.0 ~ 0.5 1.0 ~ 1.5 1.5 ~ 2.5
Outer dia.of
pipe
Torque N·m
(kgf · cm)
Small dia. side 6.35 (1/4") 14.0 – 18.0 (140 ~ 180)
Large dia. side 9.52 (3/8")
12.70 (1/2")
33.0 – 42.0 (330 ~ 420)
50.0 – 62.0 (500 ~ 620)
Valve head
cap
Small dia. side 6.35 (1/4") 19.6 – 24.5 (200 ~ 250)
Large dia. side 9.52 (3/8")
12.7 (1/2")
19.6 – 24.5 (200 ~ 250)
29.4 – 34.3 (300 ~ 350)
Valve core cap 12.3 – 15.7 (125 ~ 160)
Method to remove the low cover
● Pull at the and in the directions as
shown by arrows to remove the cover.
How to connect the optional parts
(H-LINK RAC Adapter, Dry contact, Wired Remote Controller, Run status and
alarm output)
● For cable connection to control P.W.B., you need
to remove front cover and electrical box cover.
Each connecting location is as below.
Dry contact: CN6
H-LINK RAC Adapter: CN7B
Wired Remote Controller : CN20
Relay kit for run status and alarm output:
CN25
● Please check and conrm manuals attached to
each optional parts for more connection details.
● Please check service manual about how to set
from remote controller.
● You can refer to this installation manual how to
remove and re-attach the front cover.
● Please be careful not to damage lead wires
by edge of plate when connecting the optional
parts.
● Please do the operation test after the
connection.
CN20
CN7B
CN6
CN25
!CAUTION
● Remove burr and jagged edge will cause leakage.
● Point the side to be trimmed downwards during trimming to prevent copper
chips from entering the pipe.
● Before aring, please put on the are nut.
Gas Leakage Inspection
Please use gas leakage detector to check if
leakage occurs at the connection of Flare nut
as shown on the right.
If gas leakage occurs, further tighten the
connection to stop leakage.
!CAUTION
● In case of removing are nut of a indoor unit, rst remove a nut of small diameter
side, or a seal cap of big diameter side will y out. Free from water into the piping
when working.
● Be sure to tighten the are nut to the specied torque with a torque wrench.If the
are nut is overtightened, the nut may be split after a long period has passed,
and may cause a refrigerant leak.
!WARNING
!CAUTION
Be sure that the drain hose is not loosely connected or bend or
improper conditions like above gures.
!CAUTION
You are free to choose the side (left or right) for the installation of drain hose.
Please ensure the smooth ow of condensed water of the Indoor unit during
installation. (Carelessness may result in water leakage.)
How to Remove the Front Cover How to Attach the Front Cover
1100 mm
Please bend at a small
radius to form an arc
below
5mm
Projection
Hook
about 15cm
Remove the front panel
!WARNING
● Leave some space in the connecting cord for
maintenance purpose and be sure to secure it with
the cord band.
● Secure the connecting cord along the coated
part of the wire using the cord band. Do not exert
pressure on the wire as this may cause overheating
or re.
INSTALLATION OF REFRIGERATING PIPES AND AIR REMOVAL
CONNECTION OF POWER CORDFINAL STAGE OF INSTALLATION
INSTALLATION AFTER CONNECTION OF REFRIGERATING PIPES
● The refrigerating pipe should be adjusted to t into the hole on the wall and then
ready for further connection.
● The terminals of 2 connected pipes must be covered with insulator used for terminal
connection. Then the pipes are wrapped with insulatin pipe.
● Connect the connecting cord after removing low cover. (Refer to “CONNECTION
OF POWER CORD”)
● After adjustment, t the connecting cord and pipes into the space available under
the unit. Use holder to hold them tight.
● Be sure to cut the extra binding band. (Otherwise, it may result in abnormal noise or
dewfall.)
Installation
Hang the Indoor unit onto the hanger. Use the temporary stand at
the back of the Indoor unit to push its lower part 15cm forwards.
● Place the drain hose through the hole on the wall.
● Wrap the refrigerating pipes with insulation pipe after
connecting refrigerating pipe.
● Connect the connecting cord after removing low cover. (Refer
to “Connection of Power Cord”)
● After adjustment, the connecting cord and refrigerating pipes
are placed into the space available under the Indoor unit.
● The projection of Indoor unit must hook to the mounting plate.
Pull this to the
front during the
connection of
refrigerating pipes
to ease task.
Wall hole
Pipe
Cable Drain hose
Drain layout of backward
piping from left
Refrigerating pipe
Heat insulation pipe
Connecting cord Connecting cord
Protection
pipe
Drain hose
Connected
section
Bottom Cover Removal and Installation
When connecting the refrigerant pipe, the bottom cover can be removed for
easy installation.
Bottom cover installation
● Put the 4 claws at front of the bottom cover into the indoor unit notch.
● Push the left and right claw of bottom cover into the unit.
Bottom cover
Indoor unit notch
Claw
Pipe
Drain hose
Binding band
Connecting cord
Binding band can be
installed to whichever side
of the installation points.
However, it is recommended
to attach it on the right side
viewing from the rear.
Insulation
pipe (must be
wrapped with
vinyl tape at
every 120mm)
Preparation of Pipe
Pipe Connection
HOW TO REMOVE INDOOR UNIT
● Use a pipe cutter to cut the
copper pipe.
Copper pipe
Trimming tool
DieDie
Copper pipe
● Please use exclusive tool
for refrigerant R32
● Please be careful when bending the copper pipe.
● Screw in manually while adjusting the center. After
that, use a torque wrench to tighten the connection.
Wrench
Flare nut
Torque wrench
Wiring of The Indoor Unit
● For wire connection of the Indoor unit, you need to remove
the front cover, the low cover under the body of the unit and
terminal cover.
● Remove the cover from the terminal base and screw the
cable.
● The connected terminals should be completed sealed with heat insulator
and then tied up with rubber strap.
● Do not tie the terminals with the tape too tight.
If any clearance or over-tightening may cause condensation.
● Please tie the pipe and power line together with vinyl tape as shown in
the gure showing the installation of Indoor and Outdoor units.
● To enhance the heat insulation and to prevent water condensation,
please cover the outdoor part of the drain hose and pipe with insulation
pipe.
● Completely seal any gap with putty.
Insulation material for pipe connection
Ditch
Bending upwards Condensed water pond
Sleeve of
protection pipe Putty
Putty
Condensed
water pond
Heat Insulation and Finish of the Piping
Installation of Drain Hose
THIS APPLIANCE MUST BE EARTHED.
Detail of Cutting the Connecting Cord
Strip wires
70mm
10mm
10mm
45mm
Green + Yellow (ground)
Indoor Unit
Connecting cord
After remove the screw and
the terminal cover, put the
connecting cords and x the
terminal cover with screw.
Earth
Connecting cord
Cord band
HOW TO REMOVE OR ATTACH THE FRONT COVER
Push the end of the right-side arm outward to release the tab.
Move the left-side arm outward to release the left tab, and then pull the
panel towards you.
2 Remove the lters.
3After removing 3 screws, remove the cover of electric box, pull the
center of the front cover towards you and release the claws.
4 Pull the side faces (lower sections) of the front cover towards you as
shown in the gure and remove the cover.
After installing the front cover onto the unit, hook three claws at
upper side of the cover securely. Then, push the center of the front
cover to lock the claws.
2Assemble the cover of electric box.
3Tighten the 3 screws.
4 Install the lter.
5 Attaching the Front Panel
● Insert the shaft of the left arm along the step on the unit into the
hole.
● Securely insert the shaft of the right arm along the step on the
unit into the hole.
● Make sure that the front panel is securely attached, and then
close the front panel.
Claw Claw Claw
Claw
<SIA2377: >
Screw
Cover
Screw
● Push up the (PUSH) sections at the bottom of the indoor unit
and pull the bottom plate towards you. Then the claws are
released from the stationary plate.
(The (PUSH) sections are indicated by 2 arrows as below
gure)
[PUSH] mark positions
Please remove this spacer as it is
for transportation purposes only.
Vibration and noise might occur if it
is not removed.
!CAUTION

This manual suits for next models

4

Other Hitachi Air Conditioner manuals

Hitachi RAC-25FXE User manual

Hitachi

Hitachi RAC-25FXE User manual

Hitachi RCI-2.5FSN3E(i) User manual

Hitachi

Hitachi RCI-2.5FSN3E(i) User manual

Hitachi RAM-110NP6B User manual

Hitachi

Hitachi RAM-110NP6B User manual

Hitachi airHome MultiPro RAM-G55N3HAE User manual

Hitachi

Hitachi airHome MultiPro RAM-G55N3HAE User manual

Hitachi RAS-R10C-1 User manual

Hitachi

Hitachi RAS-R10C-1 User manual

Hitachi RAS-E10HA User manual

Hitachi

Hitachi RAS-E10HA User manual

Hitachi RAS-AJ18CMT User manual

Hitachi

Hitachi RAS-AJ18CMT User manual

Hitachi RAS-18C9G User manual

Hitachi

Hitachi RAS-18C9G User manual

Hitachi 4FSVN1Q Instruction Manual

Hitachi

Hitachi 4FSVN1Q Instruction Manual

Hitachi RAK-65NH5A User manual

Hitachi

Hitachi RAK-65NH5A User manual

Hitachi RAC-VJ50PHAT User manual

Hitachi

Hitachi RAC-VJ50PHAT User manual

Hitachi YUTAKI Series User manual

Hitachi

Hitachi YUTAKI Series User manual

Hitachi RAF-35RXB User manual

Hitachi

Hitachi RAF-35RXB User manual

Hitachi RAS-30MH1 User manual

Hitachi

Hitachi RAS-30MH1 User manual

Hitachi HRNM/FSN(2)(M)(E) User manual

Hitachi

Hitachi HRNM/FSN(2)(M)(E) User manual

Hitachi RA-13KDF Specification sheet

Hitachi

Hitachi RA-13KDF Specification sheet

Hitachi RAS-18GH5 User manual

Hitachi

Hitachi RAS-18GH5 User manual

Hitachi RAS-25CNH2 User manual

Hitachi

Hitachi RAS-25CNH2 User manual

Hitachi RAS-E24CAK User manual

Hitachi

Hitachi RAS-E24CAK User manual

Hitachi RAS-DX10CFK User manual

Hitachi

Hitachi RAS-DX10CFK User manual

Hitachi RAK-25RXD User manual

Hitachi

Hitachi RAK-25RXD User manual

Hitachi RAS-10KH3 User manual

Hitachi

Hitachi RAS-10KH3 User manual

Hitachi RAW-XH07CA User manual

Hitachi

Hitachi RAW-XH07CA User manual

Hitachi RAI-25NH4 User manual

Hitachi

Hitachi RAI-25NH4 User manual

Popular Air Conditioner manuals by other brands

Mitsubishi Electric MSC-GE20VB operating instructions

Mitsubishi Electric

Mitsubishi Electric MSC-GE20VB operating instructions

Airxcel Marvair ComPac II AVHDA90 Installation & operation manual

Airxcel

Airxcel Marvair ComPac II AVHDA90 Installation & operation manual

Friedrich CCW06B10B operating instructions

Friedrich

Friedrich CCW06B10B operating instructions

Ravanson KR-8000 user manual

Ravanson

Ravanson KR-8000 user manual

Gree GWH09AB-D3DNA1D/I Service manual

Gree

Gree GWH09AB-D3DNA1D/I Service manual

Panasonic CS-LZ9ZKA operating instructions

Panasonic

Panasonic CS-LZ9ZKA operating instructions

Sharp CVP12PX - Ha Sh 11500 Btu Portable Air... Installation and operation manual

Sharp

Sharp CVP12PX - Ha Sh 11500 Btu Portable Air... Installation and operation manual

GE AEZ10AVL1 Owner's manual and installation instructions

GE

GE AEZ10AVL1 Owner's manual and installation instructions

Mitsubishi Electric Mr. SLIM PKA-M-LAL Series installation manual

Mitsubishi Electric

Mitsubishi Electric Mr. SLIM PKA-M-LAL Series installation manual

Haier HW-18LMA03(T3) Operation manual

Haier

Haier HW-18LMA03(T3) Operation manual

Panasonic CS-C12MKF-2 operating instructions

Panasonic

Panasonic CS-C12MKF-2 operating instructions

Mitsubishi Electric BRANCH BOX PAC-MKA52BC installation manual

Mitsubishi Electric

Mitsubishi Electric BRANCH BOX PAC-MKA52BC installation manual

Costway EP24581US-WH user manual

Costway

Costway EP24581US-WH user manual

Frigidaire Home ComfortFRA124HT2 Product specifications

Frigidaire

Frigidaire Home ComfortFRA124HT2 Product specifications

Trotec PAC 3500 E operating manual

Trotec

Trotec PAC 3500 E operating manual

Mitsubishi Electric Mr.SLIM SUZ-M25VA-ER Technical & service manual

Mitsubishi Electric

Mitsubishi Electric Mr.SLIM SUZ-M25VA-ER Technical & service manual

Chigo KFR-32GW/X1c Operation & installation instruction manual

Chigo

Chigo KFR-32GW/X1c Operation & installation instruction manual

Mitsubishi Electric PU(H)-P GAA installation manual

Mitsubishi Electric

Mitsubishi Electric PU(H)-P GAA installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.