4. To assign a number and initialize it to a secondary base station, press the REGISTER button on the secondary
base. Pressing the button repeatedly cycles through numbers 1, 2, and 3. When the desired number appears,
stop pressing and wait. During initialization, the STATUS display will continue showing the secondary
number. When initialization is completed, the display will show one bar, indicating that the secondary has
initialized to the primary.
5. Press the REGISTER button on the primary. The STATUS display will go blank.
6. Register Beltpacs/Headsets to the secondary (See pages 11 - 14). After registration, turn off the secondary
base and all Beltpacs/Headsets.
7. Repeat these steps for each remaining secondary base. Use a different number for each. Only the active
primary base and secondary base to be used should be powered on during initialization. All other equipment
should be turned off.
8. After all secondary bases are initialized and Beltpacs/Headsets are registered, power up all bases. Press reset
on the primary base and let it recover. Turn on the primary Beltpacs/Headsets, and let them link. Press the
reset on each secondary base (one at a time), and let it initialize to the primary (indicated by a single bar).
Turn on the Beltpacs/Headsets associated with the secondary bases one group at a time until they have all
linked. Follow with the next group. At this point, all bases and Beltpacs/Headsets should be powered up,
linked and ready for use.
9. Proceed with normal system configuration, setting functions and levels as required.
10. If it becomes necessary to replace a secondary base, use the procedure above to initialize the new secondary.
After initialization you will have to register any Beltpacs/Headsets associated with the old secondary to the
new secondary.
11. If it becomes necessary to replace a primary base, follow the above procedure completely. Before
initialization of the secondary bases, clear the previous secondary initialization as follows. For each
secondary, press the CLEAR/BAND button and the RESET button simultaneously. Continue holding the
CLEAR/BAND button after releasing the RESET button until the clear code “c” (lower case) appears on the
STATUS display. Any Beltpacs/Headsets associated with the old primary will have to be registered to the
new primary after secondary base initialization. All Beltpacs/Headsets associated with secondary base
stations also have to be registered again.
12. If the primary base is shut down or if the primary base is
powered off for more than 30 seconds, all secondary bases will
drop their Beltpac/Headset connections and begin searching for
the primary. If the primary is not found in 30 seconds, the
secondary will automatically revert to primary-mode operation
and reconnect the Beltpacs/ Headsets. At this point, the
secondary STATUS displays will show three bars. Once the
primary powered on, it will be necessary to press RESET on all
secondary bases to allow them to find and initialize to the
primary again. This makes it important that all bases be
connected to the same AC circuit to prevent this situation in the
event that the system is shut down at the end of a day and
powered up the next day.
NOTE: You cannot register Beltpacs/Headsets to a base that is set in primary mode, and then switch the
base mode to secondary for initialization. Once in secondary mode, the base cannot recognize the
Beltpacs/Headsets registered during primary operation. For secondary bases, the Beltpacs/Headsets
must always be registered after secondary base initialization, with the primary base remaining active
and the secondary base displaying one bar.