NFS-320 and NFS-320SYS and NFS-320SYS/E OPERATING
INSTRUCTIONS
This sheet must be framed and mounted adjacent to the control panel.
NFS-320 Listing Document — P/N 52748-C2 ECN: 15-687 12/31/15
Section 1 Operating Information
Normal Standby Operation.
1. Green POWER indicator lit steadily.
2. Red FIRE ALARM indicator off.
3. Yellow TROUBLE indicators off.
Alarm Condition.
1. Red FIRE ALARM indicator lit.
2. Alarm signaling devices activated.
3. Option module (remote station or supplementary alarm relay) acti-
vated.
4. Alarm information visible on LCD display.
Alarm Reset. After locating and correcting the alarm condition,
reset the control panel by pressing the SYSTEM RESET switch. If both
Fire and MNS conditions are present on the panel, SYSTEM RESET
must be pressed twice.
Trouble Conditions. Activation of trouble signal under normal
operation indicates a condition that requires immediate attention.
Contact your local service representative. Silence the audible signal by
pressing the ACKNOWLEDGE/SCROLL DISPLAY switch. The trouble
indicator will remain illuminated.
Section 2 Switch Functions
Acknowledge/Scroll Display. This silences the piezo
sounder and changes all flashing conditions to steady. Only one press
is necessary, regardless of the number of new alarms, troubles, or
supervisory signals. If the piezo is silenced, it sends an acknowledge
message to the printer and history file. Acknowledge also automati-
cally sends a special command to silence piezo sounders on the
FDU-80 and ACS Annunciators.
Signal Silence. SIGNAL SILENCE performs all the functions of
ACKNOWLEDGE. In addition, if an alarm exists, it turns off all silence-
able circuits and illuminates the SIGNALS SILENCED indicator. It also
sends a SIGNALS SILENCED message to the LCD display, printer, and
history file. A subsequent alarm will then resound the system.
Notes:
1. This unit is programmed to inhibit signal silence for ____seconds.
2. This unit is programmed to automatically silence alarm signal after
_____ minutes.
Drill. The NFS-320 and NFS-320SYS waits for the Drill switch to
be pressed for 2 seconds (to prevent accidental activations), then turns
on all silenceable circuits (all FCM-1 modules/bell circuits that are
programmed silenceable), and turns off the Signals Silenced LED. It
sends a Drill Activated message to the LCD display, FDU-80, printer,
and History file.
System Reset. Resets the control panel in standalone applica-
tions. Resets panel when enabled in network applications.
Lamp Test. Press and hold the switch to lamp-test the LEDs.
Section 3 LED Indicators
Controls Active. Green LED which illuminates when the panel
assumes control of local operation as primary display. Turns off auto-
matically when another panel assumes control of local operation.
Power. Green LED which illuminates when primary power is
applied to the control panel.
Pre-Discharge. Red LED lights when any of the releasing zones
have been activated, but have not yet discharged a releasing agent;
turns off when no releasing zones are in the pre-discharge state.
Discharge. Red LED lights when any of the releasing zones are
active and in the process of discharging a releasing agent; turns off
when no releasing zones are discharging a releasing agent.
Abort Active. Yellow LED lights when an abort switch has been
activated; turns off when an abort switch has been pressed and its
timer is still counting down. Activation of a Manual Release Switch
will override Predischarge Delay and override an active Abort Release
Switch, resulting in an immediate agent release.
Fire Alarm. Red LED that flashes when one or more alarms occur.
Illuminates steadily after alarms are acknowledged; turns off when
SYSTEM RESET is pressed after alarm clears.
Pre-Alarm. Red LED that flashes when a pre-alarm threshold is
reached. The LCD display indicates if it is an ALERT or ACTION
pre-alarm.
Security. Blue LED that illuminates for a security alarm. LED
turns off after the alarm clears and SYSTEM RESET is pressed.
Supervisory. Yellow LED that flashes when a Supervisory, Haz-
ard Alert, or Tamper condition occurs, such as a sprinkler valve tam-
per condition. The LED turns off when the Supervisory condition
clears. The MNS, Hazard Alert, or Tamper indication will latch until
reset.
System Trouble. Yellow LED that flashes when one or more
troubles occur. Goes on steadily when ACKNOWLEDGE is pressed, and
turns off when all trouble conditions are cleared. Will illuminate if the
microprocessor watchdog timer fails (CPU FAIL).
Signals Silenced. Yellow LED that illuminates after SIGNALS
SILENCED has been pressed. Turns off when DRILL or SYSTEM RESET
is pressed.
Point Disabled. Yellow LED that illuminates when one or more
points are disabled. The LCD will indicate which points have been
disabled. Turns off when points are re-enabled.
Section 4 Audible Tone Indicator
Alarm. A continuous sounding tone.
Trouble/Security. A slow, pulsating tone signal having an equal
on and off time.
Supervisory. A fast, pulsating tone signal having an equal on and
off time.
Section 5 Periodic Testing and Maintenance
To ensure proper and reliable operation, system inspection and testing
should be scheduled as required by the Authority Having Jurisdiction,
or as required by NFPA 72 or local fire codes. A qualified Service
Representative should perform testing.
Before Testing: Notify fire department and/or central alarm
receiving station if alarm condition is transmitted. Notify facility per-
sonnel of the test so alarm sounding devices are ignored during the test
period.
After Testing: Notify all fire, central station, and/or building per-
sonnel when testing is complete.
Section 6 Local Service Representative:
NAME: ________________________________________________
ADDRESS: _____________________________________________
TELEPHONE NUMBER: ________________________________

Other manuals for Notifier NFS-320

2

This manual suits for next models

3

Other Honeywell Control Panel manuals

Honeywell TotalZone TZ-4 Operation manual

Honeywell

Honeywell TotalZone TZ-4 Operation manual

Honeywell Notifier ST.PL4+ User manual

Honeywell

Honeywell Notifier ST.PL4+ User manual

Honeywell MRP-2002 User manual

Honeywell

Honeywell MRP-2002 User manual

Honeywell Galaxy 3-48C User manual

Honeywell

Honeywell Galaxy 3-48C User manual

Honeywell NOTIFIER NFW-100X User manual

Honeywell

Honeywell NOTIFIER NFW-100X User manual

Honeywell RS-232 User manual

Honeywell

Honeywell RS-232 User manual

Honeywell Notifier NFS2-640 User manual

Honeywell

Honeywell Notifier NFS2-640 User manual

Honeywell Notifier RP-2001 User manual

Honeywell

Honeywell Notifier RP-2001 User manual

Honeywell LYNX Touch 5100 Instruction Manual

Honeywell

Honeywell LYNX Touch 5100 Instruction Manual

Honeywell 5110XM User manual

Honeywell

Honeywell 5110XM User manual

Honeywell Galaxy Dimension series Quick setup guide

Honeywell

Honeywell Galaxy Dimension series Quick setup guide

Honeywell PC8900A User manual

Honeywell

Honeywell PC8900A User manual

Honeywell 013080 Instruction manual

Honeywell

Honeywell 013080 Instruction manual

Honeywell Galaxy Dimension series User guide

Honeywell

Honeywell Galaxy Dimension series User guide

Honeywell Vigilon 4 loop Installation and operation manual

Honeywell

Honeywell Vigilon 4 loop Installation and operation manual

Honeywell Fire-Lite Alarms ES-200X User manual

Honeywell

Honeywell Fire-Lite Alarms ES-200X User manual

Honeywell T631A-C FARM-O-Stat User manual

Honeywell

Honeywell T631A-C FARM-O-Stat User manual

Honeywell Tuxedo Touch Wi-Fi Assembly instructions

Honeywell

Honeywell Tuxedo Touch Wi-Fi Assembly instructions

Honeywell VARIODYN D1 Comprio Technical manual

Honeywell

Honeywell VARIODYN D1 Comprio Technical manual

Honeywell SLC User manual

Honeywell

Honeywell SLC User manual

Honeywell Flex Instruction manual

Honeywell

Honeywell Flex Instruction manual

Honeywell Fire-Lite Alarms MS-9200 User manual

Honeywell

Honeywell Fire-Lite Alarms MS-9200 User manual

Honeywell LT-32 User manual

Honeywell

Honeywell LT-32 User manual

Honeywell Farenhyt Series Technical manual

Honeywell

Honeywell Farenhyt Series Technical manual

Popular Control Panel manuals by other brands

wallas 3008 quick start guide

wallas

wallas 3008 quick start guide

Zeiss SYCOP 3 Quick reference guide

Zeiss

Zeiss SYCOP 3 Quick reference guide

Mapei Mapeheat Thermo Touch user guide

Mapei

Mapei Mapeheat Thermo Touch user guide

Frick QUANTUM Operation manual

Frick

Frick QUANTUM Operation manual

Belden Grass Valley NV9603A user guide

Belden

Belden Grass Valley NV9603A user guide

Controls MVP-62110 product manual

Controls

Controls MVP-62110 product manual

SonicAire COMMAND15 owner's manual

SonicAire

SonicAire COMMAND15 owner's manual

Grafik Eye 4100 Installer's guide

Grafik Eye

Grafik Eye 4100 Installer's guide

B&R PLC PP15 Reference manual

B&R

B&R PLC PP15 Reference manual

NetworX NX-8E-CF Installation and startup

NetworX

NetworX NX-8E-CF Installation and startup

Alertex GSM-A user guide

Alertex

Alertex GSM-A user guide

EAD LP-LPD quick start guide

EAD

EAD LP-LPD quick start guide

BFT ALENA SW2 CPEM installation manual

BFT

BFT ALENA SW2 CPEM installation manual

Siemens SIMATIC KP8 operating instructions

Siemens

Siemens SIMATIC KP8 operating instructions

BPS CLIMA CB/6V Technical manual

BPS CLIMA

BPS CLIMA CB/6V Technical manual

aguilera AE/SA-C8 installation manual

aguilera

aguilera AE/SA-C8 installation manual

Fike FCP-300 manual

Fike

Fike FCP-300 manual

Ecler essentials eMCONTROL1 user manual

Ecler essentials

Ecler essentials eMCONTROL1 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.