EmoTec D/H USA
Control unit for sauna heaters
Installation and Operating Instructions

EN-2 Installation and Operating Instructions - EmoTec D/H USA
EN Documentation
Documentation
Manufacturer
Original installation instructions EN
Copyright for these installation instructions remains with
EOS Saunatechnik GmbH.
The copying and distribution of this document, as well as the use and com-
munication of its contents without express authorization, are not permit-
ted. Compensation will be claimed in the event of infringements.
All rights reserved with regard to patent claims or submission of design or
utility patent.
Characters, symbols and illustrations
Revision history
EOS Saunatechnik GmbH
Schneiderstriesch 1
35759 Driedorf, Germany
Tel. +49 2775 82-514
Fax +49 2775 82-431
Email servicec[email protected]
Web www.eos-sauna.com
Additional information about an operating step
Cross-reference to a page
Read instructions
Result of a step
Table title
Title of figure
≤ ≥ Less than or equal to, greater than or equal to
Date Version Description
1 June 2022 01.00 First version

EmoTec D/H USA - Installation and Operating Instructions EN-3
Contents
Documentation ..................................................................................................EN-2
1 General safety instructions ..........................................................................EN-6
1.1 Mounting and electrical installation .................................................EN-6
1.2 Operator instruction................................................................................EN-8
1.3 Safety levels............................................................................................. EN-11
1.4 Standards and regulations.................................................................EN-11
2 Identification.................................................................................................... EN-12
2.1 Scope of delivery ................................................................................... EN-12
2.2 Nameplate ............................................................................................... EN-13
2.3 Technical data......................................................................................... EN-14
2.4 Accessories (optional).......................................................................... EN-16
2.5 Heating period limitation................................................................... EN-16
2.6 Intended use ........................................................................................... EN-16
3 Installation ........................................................................................................ EN-18
3.1 Routing the lines ................................................................................... EN-18
3.2 Installation work inside the cabin ...................................................EN-20
3.2.1 Setting up the sauna heater..............................................EN-21
3.2.2 Installing the temperature sensor................................... EN-21
3.2.3 Bench sensor ......................................................................... EN-24
3.2.4 Humidity sensor ................................................................... EN-24
3.2.5 Installing cabin lighting ...................................................... EN-24
3.3 Relay box .................................................................................................. EN-25
3.3.1 Requirements ......................................................................... EN-25
3.3.2 Installing the relay box........................................................ EN-27
3.4 Control panel .......................................................................................... EN-30
3.4.1 Requirements ......................................................................... EN-30
3.4.2 Mounting the control panel.............................................. EN-32
3.4.3 Mounting the fan .................................................................. EN-39

EN-4 Installation and Operating Instructions - EmoTec D/H USA
EN
4 Installation.........................................................................................................EN-40
4.1 Installation examples............................................................................EN-42
4.2 Internal view of relay box....................................................................EN-44
4.3 Circuit board assignment....................................................................EN-45
4.4 EmoTec H USA – 6-9 kW, 208 V connection diagram ...............EN-46
4.5 EmoTec D USA – 6-9 kW, 208 V connection diagram ...............EN-47
4.6 EmoTec H USA – 6-9 kW, 240 V connection diagram ...............EN-48
4.7 EmoTec D USA – 9 kW, 240 V connection diagram ...................EN-49
4.8 EmoTec H USA – 10-15 kW, 208 V connection diagram ..........EN-50
4.9 EmoTec D USA – 10–15 kW, 208 V connection diagram .........EN-51
4.10 Safety temperature limiter .................................................................EN-52
4.11 Connecting the sensors.......................................................................EN-52
4.12 Connecting the mains supply and units........................................EN-53
4.13 Closing the relay box housing...........................................................EN-54
4.14 Setting up the vaporizer (optional).................................................EN-55
5 Commissioning ...............................................................................................EN-56
5.1 Setup during commissioning or after a reset ..............................EN-57
5.2 Service settings.......................................................................................EN-58
5.2.1 Opening service settings ....................................................EN-59
5.2.2 Service/maintenance ...........................................................EN-60
5.2.3 Fan...............................................................................................EN-61
5.2.4 Refill period..............................................................................EN-62
5.2.5 Post-heating time..................................................................EN-63
5.2.6 Post-heating temperature..................................................EN-64
5.2.7 Post-cycle period for fan(s).................................................EN-65
5.2.8 Reset function.........................................................................EN-67
5.2.9 Switch contacts ......................................................................EN-68
5.2.10 Resetting the temperature display .................................EN-72
5.3 Updating firmware................................................................................EN-73
6 Operation ...........................................................................................................EN-77
6.1 Switching on and off.............................................................................EN-77
6.2 Functions ..................................................................................................EN-78
6.2.1 Overview...................................................................................EN-78
6.2.2 Operating mode ....................................................................EN-79
6.2.3 Temperature............................................................................EN-80
6.2.4 Setting the humidity for Bi-O mode ...............................EN-81

EmoTec D/H USA - Installation and Operating Instructions EN-5
6.2.5 Potential-free contact.......................................................... EN-84
6.2.6 Language ................................................................................ EN-84
6.2.7 Time ........................................................................................... EN-85
6.2.8 Date............................................................................................ EN-86
6.2.9 Screen saver ........................................................................... EN-87
6.2.10 Standby mode........................................................................ EN-87
6.2.11 Operational lock/child lock................................................ EN-88
6.2.12 Operating data ...................................................................... EN-90
6.2.13 Display brightness ................................................................ EN-94
6.2.14 Vacation home mode ......................................................... EN-94
6.3 Malfunction ............................................................................................. EN-97
7 General terms and conditions of service ........................................... EN-98
8 Disposal ............................................................................................................EN-101

EN-6 Installation and Operating Instructions - EmoTec D/H USA
EN General safety instructions
1 General safety instructions
1.1 Mounting and electrical installation
The installation instructions are intended for qualified
personnel familiar with the laws and regulations appli-
cable to electrical installations at the installation site.
Observe the following general safety instructions
during mounting, configuration and commissioning
of the product.
Risk to life and limb and risk of fire
Risk to life and limb from electric shock or fire in the event of im-
proper or faulty electrical connection. This risk remains also after
completion of the installation work.
The electrical installation of the relay box and other electrical
systems or equipment with a fixed mains connection must only
be performed by a trained electrician from an authorized elec-
trical company.
The sauna system units must be completely disconnected from
the mains supply before commencing installation and repair
work.
Ensure compliance with the applicable standards and regula-
tions for electrical installation.
The housing cover must only be removed by a trained special-
ist.
Risk of injury and fire
If the integrated battery in the control panel is not replaced cor-
rectly, there is a risk of explosion which can lead to injury and fire.
The integrated battery may only be replaced by a qualified specialist.

EmoTec D/H USA - Installation and Operating Instructions EN-7
General safety instructions
Fire hazard from overheating
Insufficient ventilation can lead to device overheating and fire.
Do not install control panels, relay boxes and modules in en-
closed cabinets or wood paneling.
Observe the sauna heater manufacturer’s safety and installa-
tion instructions.
Observe the cabin manufacturer’s safety and installation in-
structions.
Touchable glass surfaces on the outside of the cabins must not
reach more than 76°C / 171°F. Otherwise provide proper pro-
tection.
Damage to the unit
Corrosive or heavy saline atmospheres damage the contacts in the
control panel, in the relay box and on the sensors.
The control panel, relay box and sensors should not be installed
in a corrosive or heavy saline atmosphere.
Damage due to incorrect mounting location
The control unit is not suitable for outdoor use.
The unit should be operated inside buildings only. It should not
be exposed to harmful environmental conditions. Harmful en-
vironmental conditions include, for example: humidity, mois-
ture, possible formation of condensation or weather that
promotes corrosion, as well as other weather conditions.
Similarly, excessive cold and extreme exposure to sunlight must
be prevented.
Protect the unit accordingly if there is an increased risk of me-
chanical damage.

EN-8 Installation and Operating Instructions - EmoTec D/H USA
EN General safety instructions
1.2 Operator instruction
The operator of the sauna cabin must be instructed in the general
safety instructions during commissioning. The operator must be
given a copy of the operating instructions.
The operator must make the end user aware of safety instructions
that are relevant to the end user.
The operator must be familiar with the settings for the heating
time and understand how it is controlled.
Fire hazard
Objects placed on the heater can ignite and cause fires.
Do not place objects on the heater.
Fill the rock store as directed.
Inspect the sauna cabin prior to each commissioning.
Risk to life and limb from electric shock and fire
A risk to life and limb from electric shock or fire arises in the event
of improper repair work. This risk remains also after work is com-
pleted.
The housing cover must only be removed by a trained special-
ist.
Repairs and installations must only be performed by a trained
specialist.
The sauna system units must be completely disconnected from
the mains supply before commencing any repair work.
Use only original spare parts from the manufacturer.
Health risks
Spending time in a sauna cabin can lead to serious health risks or
even death for persons with health impairments.
Persons with health impairments who spend time in a sauna
must consult a doctor before entering a sauna cabin.

EmoTec D/H USA - Installation and Operating Instructions EN-9
General safety instructions
Damage to health
Excessive time spent in a heated sauna cabin can lead to overheat-
ing of the body (hyperthermia), which may cause serious health
problems and even death. Hyperthermia occurs when the core
temperature of the body exceeds the norm by a few degrees.
Symptoms of hyperthermia include fever, dizziness, lethargy,
sleepiness, and fainting. Side effects of hyperthermia include per-
ception disorders, inability to recognize the need to leave the
room, inability to identify imminent danger, harm to the fetus in
the case of pregnant women, inability to physically leave the room
and unconsciousness.
Alcohol, drugs, and medications increase the risk of hyperthermia.
Do not exceed the maximum recommended time in the sauna.
Leave the sauna cabin if your body responds abnormally to the
heat or if you do not feel well.
Avoid alcohol, drugs, and medications when you are using the
sauna.
Floor heating in the sauna cabin results in additional warming
of the legs and can lead to health risks.
Equipment damage due to overuse
Excessive humidity in commercial sauna cabins can lead to prop-
erty damage.
If the sauna cabin is used commercially, the heating time must
be set so that it switches off automatically after a specific period
of time.
If the heating does not switch off automatically after a defined
heating period, cabin use must be supervised at all times.
Inspect the cabin before each use.

EN-10 Installation and Operating Instructions - EmoTec D/H USA
EN General safety instructions
Operation by children or persons with reduced mental
capacity
Children and persons with reduced mental capacity can put them-
selves at risk.
Children must be supervised to ensure they do not play with
the unit.
Children under 8 years of age should not operate the sauna
cabin.
The settings for the heating time must only be changed by chil-
dren under 8 years of age if they are supervised by an adult.
The sauna cabin must only be used by persons with reduced
mental capacity, or limited physical or sensory abilities under
supervision or if they have been previously instructed in its use
and understand the risks.
Children and persons who have not received proper instruction
must not clean or service the system.

EmoTec D/H USA - Installation and Operating Instructions EN-11
General safety instructions
1.3 Safety levels
Safety instructions and important operating instructions are classified
according to ANSI Z535.6. Please familiarize yourself with the following
terms and symbols:
WARNING
Warning
Indicates a hazardous situation which, if not avoided, could result
in death or serious injury.
CAUTION
Caution
Indicates a hazardous situation which, if not avoided, could result
in minor or moderate injury.
NOTICE
Notice
Indicates a hazardous situation which, if not avoided, will result in
damage to the unit.
1.4 Standards and regulations
For an overview of the standards that were observed during design and
construction of the sauna heaters, please refer to the individual product’s
technical data sheet that can be downloaded from www.eos-sauna.com.
Local regulations also apply to the installation and operation of heating,
sauna, and steam room systems.

EN-12 Installation and Operating Instructions - EmoTec D/H USA
EN Identification
2 Identification
EmoTec D/H USA can be operated in the following models:
Finnish sauna mode
Steamy hot air mode
This documentation describes both models.
2.1 Scope of delivery
The following parts are included in the EmoTec D/H USA scope of delivery:
Check the scope of delivery for completeness prior to installation.
A Relay box with front cover
B Cable glands M 16
C 4 wood screws 4 x 25 mm
D 5 m connecting cable with RJ14/
RJ10 modular plug for control panel
E Installation and operating instruc-
tions
F Temperature sensor including 5 m
connecting cable with RJ10 plug,
housing, circuit board, 2 screws
4 x 40 mm
G Removal tool for control panel
H Control panel
A
B
F
E
C D
GH

EmoTec D/H USA - Installation and Operating Instructions EN-13
Identification
2.2 Nameplate
Relay box
The nameplate is affixed on the right side near the switch.
A Name
B Model
C Item number
D Operating voltage and maximum
switching output
E Protection class
F Country of origin
G Manufacturer
H Manufacturing date
I Serial number
Sauna control unit
Type EOS EmoTec H USA
Art.-Nr. 94 7770 00
208V 3N AC 60Hz 15,0 kVA
safety temperature limiter
139°C / 282°F
Made in Germany
EOS-SAUNATECHNIK GmbH, Schneiderstriesch 1, 35759 Driedorf
S-No. 38.22 00001
IPX0
5025426
CONFORMS TO
UL STD 875
CERTIFIED TO
CAN/CSA STD
E60335-1/4E
E60335-2-53
A
B
C
D
F
G
E
Sauna control unit
Type EOS EmoTec H USA
Art.-Nr. 94 7771 00
208V 3N AC 60Hz 9,0 kVA
safety temperature limiter
139°C / 282°F
Made in Germany
EOS-SAUNATECHNIK GmbH, Schneiderstriesch 1, 35759 Driedorf
S-No. 38.22 00001
IPX0
5025426
CONFORMS TO
UL STD 875
CERTIFIED TO
CAN/CSA STD
E60335-1/4E
E60335-2-53
Sauna control unit
Type EOS EmoTec H USA
Art.-Nr. 94 7772 00
240V 2N AC 60Hz 9,0 kVA
safety temperature limiter
139°C / 282°F
Made in Germany
EOS-SAUNATECHNIK GmbH, Schneiderstriesch 1, 35759 Driedorf
S-No. 38.22 00001
IPX0
5025426
CONFORMS TO
UL STD 875
CERTIFIED TO
CAN/CSA STD
E60335-1/4E
E60335-2-53
H I

EN-14 Installation and Operating Instructions - EmoTec D/H USA
EN Identification
Control panel
Software version R. 4.00 or higher must be installed in the control panel.
The nameplate is located on the inside of the front panel next to the circuit
board.
2.3 Technical data
A Name
B Item number
C Manufacturing date
D Serial number
Environmental condi-
tions
-10°C to +35°C / +14°F to +95°F
Height < 2000 m a.s.l. / 6.562 ft a.s.l.
Storage/transport tem-
perature
-20°C to +60°C / -4°F to +140°F
Housing Relay box: Metal
Control panel: Plastic
Relay box dimensions
(H x W x D)
250 x 485 x 100 mm / 9.8 x 19 x 3.9 inches
Control panel dimen-
sions
(H x W x D)
127 x 130 x 25 mm / 5 x 5.1 x 1 inch (mounted)
Mounting depth approx. 20 mm / 0.8 inch
Weight Approx. 5 kg / 11 lbs.
Control panel EmoTec D/H USA
Power supply 9 kW: 208Y /120 V AC, 60 Hz, 3N
9 kW: 240 / 120 V AC, 60 Hz, 2N
15 kW: 208Y /120 V AC, 60 Hz, 3N
Switching output Max. 9 kW resistive load with one relay circuit board
Max. 15 kW resistive load with two relay circuit boards
Fuses 9 kW: 208 V, 3N: 3 x 50 A
9 kW: 240 V, 2N: 2 x 50 A
> 9–15 kW: 208V, 3N: 2 x 3 x 50 A
Display TFT color display 55 x 74 mm / 2.2 x 2.9 inches
(3.5” diagonal)
0000194777000
EmoTec H USA
38.21
A
B
C D

EmoTec D/H USA - Installation and Operating Instructions EN-15
Identification
Temperature control Based on ambient temperature: 30°–90°C / 85°F–194°F
Control characteristics Digital two-point control
Connection for lighting Light bulb/resistive load 100 W max.
LED driver & LED lights; max. 20 W.
Minimum load: 5 W.
The inrush current of the light source must not exceed
20 A.
Sensor system Digital sensor 90°C / 194°F with safety temperature
limiter (STB)
Heating period limita-
tion
1 h
Connection for fan min. 5 W, max. 150 W
Operation 2 buttons for on/off and lighting, jog dial
Temperature control 30°–90°C / 85°F–194°F – Finnish (dry sauna mode)
30°–70°C / 85°F–158°F – Bi-O (humidity mode)
Humidity regulation Time-proportionally or optionally according to % rel.
air humidity with connected humidity sensor
Sensor system Digital sensor with safety temperature limiter (STB)
Safety temperature lim-
iter
in heater: 160°C / 320°F
in sauna cabin, on ceiling: 139°C / 282°F
Potential-free contact Load rating of contact for resistive loads:
Maximum power supply: 15 A
Maximum voltage: 30VDC / 250VAC
Error display Text on the display
Outputs 3 x RJ10 jacks for sensor connection
2 x RJ14 jacks for control panel and add-on modules
(sauna bus)
Pipe cross-sections Connections on main circuit board: AWG 14
Relay supply line: AWG 10
Connections for heater: AWG 12
Memory card reader microSD memory card reader in control panel
Connection for vapor-
izer
VAP1 and VAP2 with max. 1.5 kW each
WM for water level sensor

EN-16 Installation and Operating Instructions - EmoTec D/H USA
EN Identification
2.4 Accessories (optional)
2.5 Heating period limitation
The heating period for the sauna heater is limited to one hour.
2.6 Intended use
EmoTec D/H USA is designed to operate sauna heaters in sauna cabins. The
relay box and control panel are intended only for mounting on the wall.
EmoTec D/H USA is suitable for cabins used in private and commercial set-
tings.
The control unit is not suitable for outdoor use. It must be
operated only inside buildings and may not be exposed to
environmental conditions such as extreme humidity and
moisture or the possible formation of condensation or corro-
sive substances in the ambient air, as well as other weather
conditions. Similarly, excessive cold and extreme exposure to sunlight
must be prevented. Protect the unit accordingly if there is an increased risk
of mechanical damage.
The control unit is not suitable for installation at a height of over 2000 m
(6.562 ft).
Accessories Item no.
10 m / 32.8 ft connecting cable for control panel (RJ10/RJ14) 94.6802
10 m / 32.8 ft connecting cable for sauna bus (RJ12/RJ12) 94.5861
Modular distributor RJ12 for connecting cable for control panel
and sauna bus
2001.5298

EmoTec D/H USA - Installation and Operating Instructions EN-17
Identification
Foreseeable misuse
The following are considered instances of foreseeable misuse:
The sauna heater does not have integrated overheating protection.
The control and sensor cable plugs are plugged in incorrectly.
The unit is operated without knowledge of or compliance with the
safety instructions.
Operating, service and maintenance requirements are not observed.
The unit is operated after technical or other modifications are made to
the relay box.
The unit is operated by children or persons with reduced mental capac-
ity or by persons who have not been thoroughly instructed in its use.

EN-18 Installation and Operating Instructions - EmoTec D/H USA
EN Installation
3 Installation
3.1 Routing the lines
All lines should be routed before installing the control unit. The connec-
tions can be plugged in after installation, since the control unit’s front
panel can be removed.
NOTICE
Electronics malfunctions
Routing data and power supply lines together can lead to elec-
tronics malfunctions because, e.g., the sensor will not be detected.
Do not route sensor and sauna bus lines together with power
supply lines.
Route cable ducts separately.
Data lines must be routed and connected in such a way that they are not
openly accessible. They should be routed between the insulation and the
outer wall of the cabin. Cabin insulation must be installed in such a way
that the temperature in the area in which cables are routed
cannot exceed 65°C / 140°F.
If the data lines are installed outside on the wall, they must be protected by
a cable duct.

EmoTec D/H USA - Installation and Operating Instructions EN-19
Installation
Connecting cables and fuses
When using 4 to 6-core cables, the type of AWG cable specified in the table
increases by one unit.
Example: AWG 12 > AWG 10.
* Only use copper lines (cable type 1) that are approved for temperatures
of min. 100 °C.
** Only use copper lines (cable type 2) that are approved for temperatures
of min. 180 °C.
*** The dimensions of cables and fuses may vary. Observe the information
provided in the installation instructions for the corresponding sauna
heater.
Heater out-
put
Connection
voltage
Connecting
cablecontrol
system *
Connecting
cable
Heater **
Fuse
6.0 kW 208 V AWG 10 AWG 12 25 A
7.5 kW 208 V AWG 10 AWG 12 30 A
9.0 kW 208 V AWG 8 AWG 12 35 A
10.5 kW 208 V AWG 10 AWG 12 25 A
12 kW 208 V AWG 10/8*** AWG 12 25/35 A***
15 kW 208 V AWG 8 AWG 12 40 A
6.0 kW 240 V AWG 12 AWG 12 15 A
7.5 kW 240 V AWG 12 AWG 12 20 A
9.0 kW 240 V AWG 12 AWG 12 20 A
15 kW 208 V AWG 12 35 A

EN-20 Installation and Operating Instructions - EmoTec D/H USA
EN Installation
3.2 Installation work inside the cabin
At minimum, the cabin lighting and a temperature sensor with safety tem-
perature limiter must be installed inside the cabin.
Example – cabin
The temperature sensor must be installed where expected temperatures
are the highest.
A Cabin fan
B Light
C Temperature sensor with safety tem-
perature limiter
A
B
C
Other manuals for Emotec D
3
This manual suits for next models
3
Table of contents
Other EOS Control Unit manuals