manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Honeywell
  6. •
  7. Controllers
  8. •
  9. Honeywell SILENT KNIGHT SK-Control Manual

Honeywell SILENT KNIGHT SK-Control Manual

INSTALLATION AND MAINTENANCE INSTRUCTIONS
BEFORE INSTALLING
This information is included as a quick reference installation guide. Refer to
the control panel installation manual for detailed system information. If the
modules will be installed in an existing operational system, inform the opera-
tor and local authority that the system will be temporarily out of service. Dis-
connect power to the control panel before installing the modules.
NOTICE: This manual should be left with the owner/user of this equipment.
GENERAL DESCRIPTION
SK-Control Supervised Control Modules are intended for use in intelligent,
two-wire systems, where the individual address of each module is selected
using the built-in rotary switches. This module is used to switch an external
power supply to notification appliances. It also supervises the wiring to the
connected loads and reports their status to the panel as NORMAL, OPEN, or
SHORT CIRCUIT. The SK-Control has two pairs of output termination points
available for fault-tolerant wiring and a panel-controlled LED indicator.
COMPATIBILITY REQUIREMENTS
To ensure proper operation, this module shall be connected to a compatible
Silent Knight system control panels only (list available from Silent Knight).
MOUNTING
The SK-Control mounts directly to 4-inch square electrical boxes (see
Figure 2A). The box must have a minimum depth of 21/8inches. Surface
mounted electrical boxes (SMB500) are available.
WIRING
NOTE: All wiring must conform to applicable local codes, ordinances, and
regulations. When using control modules in nonpower limited applications,
UL requirements for the separation of power-limited and nonpower-limited
terminals and wiring must be met. The barrier must be inserted into a 4˝ × 4˝
× 21/8˝ junction box, and the control module must be placed into the barrier
and attached to the junction box (Figure 2A). The power-limited wiring must
be placed into the isolated quadrant of the module barrier (Figure 2B).
SPECIFICATIONS
Normal Operating Voltage: 15 to 32 VDC
Maximum Current Draw: 6.5 mA (LED on)
Average Operating Current: 375 µA (LED flashing - in group poll mode) 350 µA (LED flashing - in direct poll mode) 485 µA Max. (LED flashing, NAC shorted)
Maximum NAC Line Loss: 4 VDC
Reg. Ext. Supply Voltage: (between Terminals T3 and T4)
Maximum (NAC): Regulated 24 VDC
Drain on External Supply: 1.7 mA Maximum (using 24 VDC supply)
Max. NAC Current Ratings: For Class B wiring system, 3 A; For Class A wiring system, 2 A
Temperature Range: 32°F to 120°F (0°C to 49°C)
Humidity: 10% to 93% Non-condensing
Dimensions: 4.675” H x 4.275” W x 1.4” D (Mounts to a 4˝ square by 21/8˝ deep box.)
Accessories: SMB500 Electrical Box
I56-3436-004
1. Install module wiring in accordance with the job drawings and appropri-
ate wiring diagrams.
2. Set the address on the module per job drawings.
3. Secure module to electrical box (supplied by installer), as shown in
Figure 2A.
IMPORTANT: When using the SK-Control for audio applications, remove
Jumper (J1) and discard. The Jumper is located on the back as shown in
Figure 1B.
NOTE: All references to power limited represent “Power Limited (Class 2)”.
All references to Class A also include Class X.
FIGURE 1A. CONTROLS AND FIGURE 1B. JUMPER LOCATION:
INDICATORS:
J1
C1059-00 C0910-00
RELAY CONTACT RATINGS:
CURRENT RATING MAXIMUM VOLTAGE LOAD DESCRIPTION APPLICATION
2 A 25 VAC PF = 0.35 Non-coded
3 A 30 VDC Resistive Non-coded
2 A 30 VDC Resistive Coded
0.46 A 30 VDC (L/R = 20 ms) Non-coded
0.7 A 70.7 VAC PF = 0.35 Non-coded
0.9 A 125 VDC Resistive Non-coded
0.5 A 125 VAC PF = 0.75 Non-coded
0.3 A 125 VAC PF = 0.35 Non-coded
1 I56-3436-004
04-12
I56-3436-004
INSTALLATION AND MAINTENANCE INSTRUCTIONS
12 Clintonville Road, Northford, CT 06472-1610
Phone: 203-484-7161 Fax: 203-484-7118
www.silentknight.com
SK-Control
Supervised Control Module
FIGURE 3. TYPICAL NOTIFICATION APPLIANCE CIRCUIT CONFIGURATION, NFPA STYLE Y:
(+)
(+)
(+)
(+)
(+)
(+)
47K EOL
RESIST
OR
ELR-47K
UL LISTED EOL
RELAY SHOWN
ENERGIZED
24 VDC COIL
EOLR-1
24 VDC CIRCUIT
DO NOT LOOP WIRE ON TERMINALS 10 & 11. BREAK WIRE
RUN TO PROVIDE SUPERVISION OF CONNECTIONS.
TO NEXT CONTROL MODULE OR
END-OF-LINE RELAY. ONE RELAY
REQUIRED FOR EACH CIRCUIT. SOME
CONTROL PANELS HAVE RELAY BUILT
IN AND DO NOT REQUIRE EXTERNAL
WIRING. REFER TO PANEL MANUAL.
24 VDC POWER SUPPLY
ISOLATED, REGULATED,
POWER LIMITED PER NFPA 70.
LISTED FOR FIRE PROTECTION
WITH BATTERY BACKUP.
MODULE POLARITIES ARE
SHOWN IN ALARM
CONNECT MODULES TO
LISTED COMPATIBLE CONTROL
PANELS ONLY
SIGNAL LINE CIRCUIT (SLC)
32 VDC MAX.
TWISTED PAIR
IS RECOMMENDED
ALL WIRING SHOWN IS SUPERVISED
AND POWER LIMITED
CONTROL
MODULE
FROM PANEL
OR PREVIOUS
DEVICE
TO NEXT
DEVICE
*NOTE: ANY FAULT IN THE POWER SUPPLY IS LIMITED TO THAT ZONE AND DOES NOT RESULT IN A FAULT IN A SEPARATE ZONE.
(–) (–)
(–) (–)
(–)
(–)
C0947-00
FIGURE 4. TYPICAL FAULT TOLERANT NOTIFICATION APPLIANCE CIRCUIT CONFIGURATION, NFPA STYLE Z:
(+)
(–)
(+)
(–)
(+)
(–)
(–)
(+)
(–)
(+)
(+)
(–)
ALL WIRING SHOWN IS SUPERVISED
AND POWER LIMITED
MODULE POLARITIES ARE
SHOWN IN ALARM
EOL RESISTOR
IS INTERNAL
AT TERMINALS
8 AND 9
UL LISTED EOL
RELAY SHOWN
ENERGIZED
24 VDC COIL
EOLR-1
TO NEXT CONTROL MODULE OR
END-OF-LINE RELAY. ONE RELAY
REQUIRED FOR EACH CIRCUIT. SOME
CONTROL PANELS HAVE RELAY BUILT
IN AND DO NOT REQUIRE EXTERNAL
WIRING. REFER TO PANEL MANUAL.
CONTROL
MODULE
TO NEXT
DEVICE
SIGNAL LINE CIRCUIT (SLC)
32 VDC MAX.
TWISTED PAIR
IS RECOMMENDED
CONNECT MODULES TO LISTED
COMPATIBLE CONTROL
PANELS ONLY
FROM PANEL
OR PREVIOUS
DEVICE
24 VDC CIRCUIT
DO NOT LOOP WIRE ON TERMINALS 10
& 11. BREAK WIRE RUN TO PROVIDE
SUPERVISION OF CONNECTIONS.
24 VDC POWER SUPPLY
ISOLATED, REGULATED,
POWER LIMITED PER
NFPA 70. LISTED FOR
FIRE PROTECTION WITH
BATTERY BACKUP.
*NOTE: ANY FAULT IN THE POWER SUPPLY IS LIMITED TO THAT ZONE AND DOES NOT RESULT IN A FAULT IN A SEPARATE ZONE.
C0948-00
WARNING
All relay switch contacts are shipped in the standby state (open) state, but may have transferred to the activated (closed) state during shipping. To ensure that
the switch contacts are in their correct state, modules must be made to communicate with the panel before connecting circuits controlled by the module.
FIGURE 2A. MODULE MOUNTING FIGURE 2B: WITH BARRIER:
C1047-00
2 I56-3436-004
©2017 Honeywell. 04-12
Silent Knight®and Honeywell®are registered trademarks of Honeywell International, Inc.

Other Honeywell Controllers manuals

Honeywell H46C User manual

Honeywell

Honeywell H46C User manual

Honeywell HC900 User manual

Honeywell

Honeywell HC900 User manual

Honeywell CIPer 50 Installation and operation manual

Honeywell

Honeywell CIPer 50 Installation and operation manual

Honeywell SDW 30 User manual

Honeywell

Honeywell SDW 30 User manual

Honeywell Tradeline H1008A Operation manual

Honeywell

Honeywell Tradeline H1008A Operation manual

Honeywell DC1010 Quick start guide

Honeywell

Honeywell DC1010 Quick start guide

Honeywell dcp100t User manual

Honeywell

Honeywell dcp100t User manual

Honeywell AQS51-KAM Operation manual

Honeywell

Honeywell AQS51-KAM Operation manual

Honeywell S9200U1000 User manual

Honeywell

Honeywell S9200U1000 User manual

Honeywell Touchpoint Plus User manual

Honeywell

Honeywell Touchpoint Plus User manual

Honeywell Mini-AT User manual

Honeywell

Honeywell Mini-AT User manual

Honeywell Ex-Or MLSM2000A Installation and operation manual

Honeywell

Honeywell Ex-Or MLSM2000A Installation and operation manual

Honeywell Excel 50 User manual

Honeywell

Honeywell Excel 50 User manual

Honeywell ML6420 Operation manual

Honeywell

Honeywell ML6420 Operation manual

Honeywell HJZTP User manual

Honeywell

Honeywell HJZTP User manual

Honeywell DBC2000E10 Series User manual

Honeywell

Honeywell DBC2000E10 Series User manual

Honeywell UDC3200 series User manual

Honeywell

Honeywell UDC3200 series User manual

Honeywell Lyric Product information sheet

Honeywell

Honeywell Lyric Product information sheet

Honeywell DBC2000 Series User manual

Honeywell

Honeywell DBC2000 Series User manual

Honeywell PCR-310 User manual

Honeywell

Honeywell PCR-310 User manual

Honeywell DC1000 SERIES User manual

Honeywell

Honeywell DC1000 SERIES User manual

Honeywell VK41 V Series User manual

Honeywell

Honeywell VK41 V Series User manual

Honeywell VR4304 Series User manual

Honeywell

Honeywell VR4304 Series User manual

Honeywell SEC-H-602 User manual

Honeywell

Honeywell SEC-H-602 User manual

Popular Controllers manuals by other brands

IFM Electronic Ecomat 100 ecomatmobile SmartController... System manual

IFM Electronic

IFM Electronic Ecomat 100 ecomatmobile SmartController... System manual

JYTEK PXIe-63935 user manual

JYTEK

JYTEK PXIe-63935 user manual

DALCNET DTDMX16C Technical handbook

DALCNET

DALCNET DTDMX16C Technical handbook

Ninja LPRV2 Startup guide

Ninja

Ninja LPRV2 Startup guide

Prolyft PLE-30-044 user manual

Prolyft

Prolyft PLE-30-044 user manual

Mitsubishi AJ65SBT2B-64RD3 user manual

Mitsubishi

Mitsubishi AJ65SBT2B-64RD3 user manual

NOVAK GTX manual

NOVAK

NOVAK GTX manual

Mitsubishi Electric FX2N-10GM user guide

Mitsubishi Electric

Mitsubishi Electric FX2N-10GM user guide

AEG Modicon Micro 84 user manual

AEG

AEG Modicon Micro 84 user manual

RF Mogul RFM-1000 Technical manual

RF Mogul

RF Mogul RFM-1000 Technical manual

Cass Technology CASTLE S SERIES Technical operation guide

Cass Technology

Cass Technology CASTLE S SERIES Technical operation guide

LEGRAND 0 883 27 quick start guide

LEGRAND

LEGRAND 0 883 27 quick start guide

TSI Instruments PRESSURA RPC30 Operation and service manual

TSI Instruments

TSI Instruments PRESSURA RPC30 Operation and service manual

Simons Voss Technologies SmartRelais 3 Advanced quick guide

Simons Voss Technologies

Simons Voss Technologies SmartRelais 3 Advanced quick guide

TP-Link AC50 Configuration guide

TP-Link

TP-Link AC50 Configuration guide

Eaton LMR PLUS manual

Eaton

Eaton LMR PLUS manual

RLE Technologies SeaHawk 10K user guide

RLE Technologies

RLE Technologies SeaHawk 10K user guide

RIB B2 24V manual

RIB

RIB B2 24V manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.