Product Installation Document
1 Overview
The Honeywell HPT724 is a programmable LCD timer that is designed to support a wide range of applications. Such
applications can include: home and building automation, security, access control, lighting control, etc. The HPT724 is
equipped with an independently controlled form “C” relay contact that provides many latching and/or momentary
operations during a program schedule of your choice. The EE prom memory allows for programming 24 hour 365 day
events prior to/during field installation. Events may be set for single or multiple operations on a daily and/or weekly
schedule. The block programming feature enables repeating and event on any combination of consecutive days. The
HPT724 will compensate for daylight saving time if desired. Individually selected holiday exceptions can be
programmed to over-ride regularly scheduled events.
2 Specifications
• 12/24 volts, 500mA AC or DC operation.
• Standby Current: 10 mA (relay off), 50 mA (relay on).
• Battery Charging Current: 100 mA.
• Form “C” relay contacts are rated 10 amp @ 120 VAC/28 VDC.
• EE Prom memory protects against loss of programming due to power failure.
• Accurate crystal-controlled clock (displays time in military format).
• Momentary and/or latching events.
• 50 individually programmed daily/weekly events.
• Block programming capacity can accommodate a total of 350 events per week.
• 10 programmable holiday dates.
• “First man in” option.
• Alphanumeric LCD display simplifies programming.
• Standard or daylight saving settings.
• Automatic compensation for leap year.
• Built-in charger for 12 VDC sealed lead acid or gel type batteries (standby battery maintains operation during power
failure until discharged).
• Lithium battery backup maintains clock (optional; battery is 3V, model CR2032).
• Board Dimension: 5.25"W x 3"L x 1"D (approximate).
3 Installation Instructions
1. Mount HPT724 in desired location, using suitable standoffs/fasteners, tape or HST34 snap track.
2. Connect 12 or 24 volts at 500 mA of AC or DC to terminals marked [+DC-- ~AC~]. (When using DC, carefully
observe polarity.)
3. Connect 12 VDC battery (optional) to terminals marked [+BAT-- 12VDC].
4. Insert lithium battery (optional/not included) in battery holder with the positive (+) side facing up (Fig-1).
5. Connect devices to be controlled to the dry outputs marked [NO, C, NC].
6. Program clock and desired event schedule (see Sec-5).
Continued on next page...

2HPT724 Installation Document P/N 52765:A 1/25/06
NOTE: When connecting DC powered electromechanical devices such as Mag Locks, Electric Strikes, Bells, Relays, etc. install a catch diode
across the positive (+) and negative (-) terminals of the device. Connect diode as close to the device as possible with the banded side facing the
positive (+) terminal. This will reduce the possibility of interference.
4 Basic Operation
The HPT724 controls an independently operated dry form “C” relay output. Relay can be programmed to: turn on
(latch), turn off (release latch), or pulse (momentary toggle) at a specified time and day (this is referred to as an event).
Events are programmed via the push buttons and LCD display. Events may be programmed to occur on any day of the
week at any time. In addition, events may be repeated at a specific time on two (2) or more consecutive days (i.e. M-F,
Sun -Th, etc.). Multiple combinations of individual and block events may be programmed. Holiday exceptions are
individually selected by date and will override all regularly scheduled events.
The four (4) output relay modes consist of:
Relay OFF -- De-energizes the relay until a relay ON event is detected.
Relay ON -- Energizes the relay until a relay OFF event is detected.
Disable -- Used to cancel an existing programmed event.
Pulse -- Momentarily energizes the relay for a selectable time period of 1 to 15 seconds.
(Time is displayed in 24 hour military format.)
5 Terminal Identification Table
NO
C
NC
Dry contact output used to switch controlled devices. When these
relays are energized (ON) the NC and C terminals are open and the
NO and C terminals are closed. When this relay is de-energized
(OFF) the NC and C terminals are closed and the NO and C terminals
are open.
+ DC --
~ AC ~
AC or DC input 12 to 24 volt. When using DC, carefully observe
polarity.
+ BAT --
12VDC
12 VDC standby battery input (battery leads provided).
FM When this terminal is connected to DC neg. (-), the “First Man In”
feature is enabled. The relay will remain in its present position until
the connection is terminated. At that time the relay will resume normal
operation and latest scheduled events will occur.
Continued on next page.
..

HPT724 Installation Document P/N 52765:A 1/25/06 3
6 Push Button Description Table
7 Programming Instructions
A. Setting Clock/Calendar:
Enter the current date, day of the week and time (military) by depressing UP and DWN to make the selction, then depress
ENTER to accept. Next, select either DS (daylight savings mode) or ST (standard time mode) by sepressing SET until
“ENTER to SET BK: appears in display as shown below.
Push Button Function/Description
SET Scrolling keys for programming. Escaping out of existing programming.
ENTER Accepts selections made to progamming.
UP Scrolls through selections.
DWN Scrolls through selections.
UP and DWN keys can be used to select data entries. After scrolling to the correct entry, depress ENTER to accept.
SET ENTER UP DWN
+DC--
~AC~
FM
+BAT--
12VDC
NO CNC
Standby Battery Lithium Battery Socket
(order model #CR2032)
Push Button Layout
Output Contact
Terminals
LCD Display
12-24volt
AC/DC Input
First Main In Terminal
RLY OFF
SU 01:01
ENTER to
SET TIME
01/01/01
SU 01:01
Upon initial power up will appear in display.
Depress SET will appear in display.
Depress ENTER will appear in display.
ENTER to
SET BK
Continued on next page
...

4HPT724 Installation Document P/N 52765:A 1/25/06
Depress ENTER to scroll until flashing cursor appears under DS (daylight savings mode) in display. To change mode
depress UP or DWN once and ST (standard time mode) will appear in display. Depress ENTER to accept correct
selection. Note: The flashing cursor denotes location of data entry selection to be made. If an entry was made in error or
requires changing, depress SET to backspace, make the correct selection and depress ENTER to accept data and advance
the cursor.
To change or program clock/calendar simply repeat the steps above.
B. Setting Events
Depress ENTER until the flashing cursor appears under OFF in display. Now select type of event required by scrolling
using the UP and DWN push buttons until either ON, OFF, or PL appears in display (ON-Relay ON [latching mode],
OFF-Relay OFF [latching mode], PL-Relay Pulse [momentary]). Depressing ENTER will make selection. When
selecting pulse mode PL01 will appear in display. It is now necessary to assign the length of time (duration of relay
activation). The pulse can range in length from 1 to 15 secondsand is selected using UP or DWN push buttons then
depressing ENTER to accept. Note: If pulse duration is not selected relay output defaults to 1 second. Next, select the
day of the week and time (military) by using UP or DWN and depressing ENTER to accept. You may continue to
program events by repeating the previous steps or exit programming by depressing SET. Note: When programming
additional events it is necessary to select the next consecutive event number following the last event program to continue.
Also, when it is required to have the same event repeated on two (2) or more consecutive days of the week (block
programming), enter the first day followed by the last day by depressing SUN through SAT. Example--Monday through
Thursday, depress MON followed by THURS. For Wednesday through Sunday, depress WED followed by SUN.
C. Setting Block Events (weekly repeat):
A flashing cursor will appear at the location of te first day of the week desired. Depress UP and DWN to delect day.
Depress ENTER to confirm selection, then cursor will appear at the location of the last day of the week desired. Depress
UP and DWN to select day. Depress ENTER to confirm selection. Depress ENTER again to escape.
D. Setting Holiday Events:
Next, select HL to indicate as holiday event and time by using UP and DWN push buttons and depress ENTER to accept.
You may continue to program more holiday events by repeating the previous steps or exit programming by depressing
SET.
ENTER to
SET EVENT
#01^OFF
SU 00:00
Depress SET until appears in display.
Depress ENTER will appear in display.
ENTER to
SET BK
BK=SA/SU
TIME=DS
Depress SET until appears in display.
Depress ENTER will appear in display.
ENTER to
SET EVENT
#01^ON
HL 00:00
Depress SET until appears in display.
Depress ENTER will appear in display.
Continued on next page.
..

HPT724 Installation Document P/N 52765:A 1/25/06 5
E. Setting Holiday Dates:
It is now necessary to assign these holiday events specific calendar dates on which they are to occur. To select holiday
events depress SET until “ENTER to SET HOL” appears in display as shown below. Note: Holiday events will override
all regularly programmed events.
F. Delete/Disable Event or Edit Event:
Previously programmed regularly scheduled and/or holiday events may be deleted/disabled without having to erase all
events.
Now scroll, using UP and DWN push buttons, to the event you wish to delete, then depress ENTER to move flashing
cursor under relay option then depress UPand DWN push button until DIS is displayed, depress ENTER to confirm.
G. Delete All Events:
All previously programmed events can be deleted by depressing SET until “ENTER to CLR MEM” appears in display as
shown below.
Depressing UP push button will now clear all events previously programmed. If you wish to escape from this selection,
depress any of the other push buttons; SET, ENTER, or DWN.
For additional information:
• Visit our website at http://www.honeywellpower.com
• Contact Technical Support at 1(877) HPP-POWR
• E-mail us at hpp.techserv@honeywell.com
ENTER to
SET HOL
#01^HOL
SU 00:00
Depress ENTER will appear in display.
ENTER to
SET EVENT
#01^ON
TU 00:00
Depress SET until appears in display.
Depress ENTER will appear in display.
ENTER to
CLR MEM
CLEAR
MEMORY?
PRESS UP
& ACCEPT
Depress ENTER until appears in display.
Depress ENTER will appear in display.

6HPT724 Installation Document P/N 52765:A 1/25/06
Customer Event Log
Event # Relay # Day/Block Holiday Dates Event Type
Table of contents
Other Honeywell Timer manuals

Honeywell
Honeywell PLS750C User manual

Honeywell
Honeywell ST7997 User manual

Honeywell
Honeywell ST7009 A User manual

Honeywell
Honeywell ST9100S User manual

Honeywell
Honeywell ST9120U User manual

Honeywell
Honeywell 46213 User manual

Honeywell
Honeywell ST699 User manual

Honeywell
Honeywell ST7009A User manual

Honeywell
Honeywell 45959 User manual

Honeywell
Honeywell ST9100S User manual