10. Check Battery Procedure.
The following procedure should be used to determine the battery condition.
•Within the first two minutes after power up, while the unit is in state 11, Waiting (%SR196),
check the battery voltage from the System Menu or %SR198.
oWhen charging, the voltage reading is affected by the charging circuit and therefore
will not be an accurate read. Check battery voltage in a non-charging state.
•A battery may be considered low at less than 4.0 volts. But this is not an indication of a bad
battery.
oAny low battery should be given time to charge before deciding if it is bad or not.
oIn general, let the OCS charge the battery overnight or at least for a few hours, cycle
power to the controller, and check the battery voltage during the Waiting state.
•There are 5 charging states, which are based on battery temperature. (not ambient)
oNot Charging = below 0°C
Cold Charging = 0-10°C - charge current = 20mA (Charges to 4.2 volts)
Normal Charging = 11-45°C - charge current = 100mA (Charges to 4.2 volts)
Hot Charging = 46-60°C - charge current = 20mA (Charges to 4.1V)
Not Charging = greater than 60°C
oThe battery temperature can be gauged by taking the CPU temperature and
subtracting 30°C.
▪Example, in battery status, CPU temperature shows 73°C. The battery
temperature is 43°C and the charging state would be state 1, Normal
Charging.
•When charging in state 2 (Hot Charging) or state 5 (Cold Charging) the current is lower and
so will take much longer to charge. (See %SR196 for state).
oStates 2 or 5 can take up to 40 hours to fully charge a battery, depending on its level
at the beginning of charging.
oState 1, Normal Charging can take up to 8 hours to fully charge a battery, depending
on its level at the beginning of charging.
oIf a battery is only slightly low or close to fully charged, it may only take a few
minutes to fully charge the battery.
•If a battery is completely dead, the battery status from System Menu or %SR198 will still
show around 3.2 to 3.5 volts. This is not the battery, but the supporting circuitry voltage.
oIf the battery if very low or dead, the OCS will fail self-test and show a ‘Battery:
Warning’ in diagnostics. %SR55.13 will be set ON.
o3.2 to 3.5 volts is very low. In this case it would be a good idea to remove the battery
and check it with a volt meter.
▪If the battery shows 1 volt or less, it is dead and should be replaced.
▪If the battery measures greater than 1 volt, let it charge for a few hours
and see if there is improvement or not by checking the voltage while the
OCS is in a non-charging state such as the first two minutes after
powering up the unit.