HORNER XLE-Model 2 User manual

Page 1
XLE/XLEe & XLT/XLTe - Model 2
12 DC In, 6 Relay Out, 4 – 12-bit Analog In
MAN1113-22-EN_XLET_Mod2
FindthemanualsviatheDocumentationSearchpageon
theHornerwebsite.
Part Numbers
Global Part Numbers
XLE-Model2 HE-XE102
XLEe-Model2withEthernet HE-XE1E2
XLT-Model2 HE-XT102
XLTe-Model2withEthernet HE-XT1E2
European Part Numbers
XLE-Model2 HEXE220C112
XLEe-Model2withEthernet HEXE221C112
XLT-Model2 HEXT240C112
XLTe-Model2withEthernet HEXT241C112
Accessories and Add-Ons
Part# Description
HE-BAT009 CR2450LithiumCoinBattery
HE-XCK ProgrammingCables
HE-XDAC 2channelAnalogOutputI/Ooptionkit,
selectable0-10V,+/-10V,4-20mA.
HE-XDAC107 4channelAnalogOutputI/Ooptionkit,
selectable0-10V,+/-10V,4-20mA.
HE-XKIT BlankI/OBoard
HE200MJ2TRM Adapter,RJ45(8P8C)maleto8-pos-
itionterminalstrip.
HE-FBD001 Ferritecoreforfilteringoutelectrical
noise.
XLE/XLT User Manual - MAN0878
FindtheusermanualviatheDocumentationSearchpage
ontheHornerwebsite.
Table of Contents
TECHNICAL SPECIFICATIONS 2
GeneralSpecifications 2
ControlandLogic 2
UserInterface 2
Connectivity 2
CONTROLLER OVERVIEW 3
OverviewofXLEandXLT 3
PowerWiring 3
Model 2 Specifications 4
DigitalDCInput 4
DigitalRelayOutputs 4
AnalogInputs,MediumResolution 4
WIRING: INPUTS AND OUTPUTS 5
AnalogInputsInformation 5
DigitalInputs 5
RelayLife 5
JumperSettingsforModel2 5
BackPanelTorqueRatings 5
J1Wiring-DigitalIn/AnalogIn 6
J2Wiring-RelayOut/AnalogorDigitalIn 6
WiringDetails 6
BUILT-INI/O 6
AnalogInputTranzorbFailure 6
COMMUNICATIONS 7
SerialCommunication 7
Ethernet 7
CANCommunications 7
DipSwitches 7
DIMENSIONS & INSTALLATION 8
Dimensions&PanelCutout 8
InstallationInformation 8
InstallationProcedure 8
BatteryMaintenance 8
SAFETY & MAINTENANCE 9
Warnings 9
FCCCompliance 9
TechnicalSupport 9
Precautions 9

Page 2
TECHNICAL SPECIFICATIONS
General Specifications
PrimaryPowerRange 10-30VDC
Max.Current 500mA,Class2
750mA,Class2withheater*
RequiredPower
(SteadyState) 130mA@24VDC
InrushCurrent 30Afor<1ms
Typicalpowerback-
light100%
136mA@10V(1.36W)
64mA@24V(1.53W)
PowerBacklightOff 15mA@24V(0.36W)
PowerEthernet
Models
35mA@10V(0.35W)
20mA@24V(0.48W)
HeaterOption* 250mA@24VDCwithheater*
RealTimeClock Batterybacked;lithiumcoincell
CR2450
ClockAccuracy +/-90Secs/Month
RelativeHumidity 5to95%Non-condensing
OperatingTemp. -10°Cto+60°C
StorageTemp. -20°Cto+70°C
Weight 0.75lbs/340g(withoutI/O)
Altitude Upto2000m
RatedPollution
Degree
EvaluatedforPollutionDegree2
Rating
Certifications(UL/CE) NorthAmericaorEurope
EnclosureType 1,3R,4,4X,12,12K&13
*HeaterOption(Model#plus"-22")
Control and Logic
ControlLang.
Support
Register-BasedAdvancedLad-
der;
Variable-BasedAdvancedLad-
der;
IEC61131-3Languages
LogicProgramSize 256kB
ScanRate 0.7ms/kBlogic(XLE)
0.8ms/kBlogic(XLT)
DigitalInputs 2048
DigitalOutputs 2048
AnalogInputs 512
AnalogOutputs 512
Gen.Purpose
Registers
9,999(words)Retentive
2,048(bits)Retentive
2,048(bits)Non-retentive
User Interface
DisplayType TransflectiveLCDSun-light
Readable
Resolution 128x64pixels(XLEe)
160x128pixels(XLTe)
Color Monochrome
Built-InStorage 16MB
User-Program.
Screens
1023maxpages;
50objectsperpage
Backlight LED
BacklightLifetime 30,000+hrs
BrightnessControl
0-100%(XLT)
On/Off(XLE)via
SystemRegister%SR57
NumberofKeys 20(XLE)
5(XLT)
Touchscreen(XLTe) Resistive1,000,000+touchlife
Connectivity
SerialPorts
RS-232fullhandshakingorRS-
485halfduplexonfirstModular
Jack(MJ1)
RS-232orRS-485onsecond
ModularJack(MJ2)
USBMini-B Programmingonly
CAN 1xCANPort,Isolated1kV
CAN
Protocols
CsCAN,CANopen,DeviceNet,
J1939
Ethernet Ethernetversionsonly
(XLEe&XLTe)
Ethernet
Protocols
TCP/IP,ModbusTCP,FTP,
SRTP,EGD,ICMP,ASCII
RemoteI/O SmartRail,SmartStix,
SmartBlock,SmartMod
RemovableMemory
MicroSD,SDHC,SDXC,IN
FAT32format,supportfor32GB
max.ApplicationUpdates,
Datalogging
Audio
(XLTeonly)
Beeper,Systemor
SoftwareControlled

Page 3
CONTROLLER OVERVIEW
Overview of XLE and XLT
1. FunctionKeys
2. Touchscreen
3. NavigationKeys
4. USBMini-BPort
5. HighCapacitymicroSDSlot
6. RS232/RS485SerialPorts(2)
7. Wide-RangeDCPower
8. CANPort
9. EthernetLANPort(XLEeandXLTeonly)
10. OptionalBuilt-InI/O(Models2-6only)
11. ConfigurationSwitches
12. MountingClipLocations
13. DINRailClip
14. Softkeys
NOTE:SeePrecaution#12onaboutUSBandgrounding.
Power Wiring
NOTE:ThePrimaryPowerRangeis10VDCto30VDC.
Primary Power Port Pins
PIN Signal Description
1 Ground FrameGround
2 DC- InputPowerSupplyGround
3 DC+ InputPowerSupplyVoltage
DC Input / Frame
lSolid/StrandedWire:12-24awg(2.5-0.2mm)
lStriplength:0.28”(7mm)
lTorque,TerminalHold-DownScrews:4.5–7in-lbs
(0.50–0.78N-m)
lDC-isinternallyconnectedtoI/OV-,butisisolated
fromCANV-.AClass2powersupplymustbeused.
Power Up
1. OPTION:Attachferritecorewithaminimumoftwo
turnsoftheDC+andDC-signalsfromtheDCsupply
thatispoweringthecontrollers.
2. Connecttoearthground.
3. Applyrecommendedpower.

Wiring:Model 2
Page 4
Model 2 Specifications
Digital DC Input
InputsperModule 12including4configurableHSC
inputs
CommonsperModule 1
InputVoltageRange 12VDC/24VDC
AbsoluteMax.
Voltage 30VDCMax.
InputImpedance 10kΩ
InputCurrent PositiveLogic NegativeLogic
UpperThreshold
LowerThreshold
0.8mA
0.3mA
-1.6mA
-2.1mA
Max.UpperThreshold 8VDC
Min.LowerThreshold 3VDC
OFFtoONResponse 1ms
ONtoOFFResponse 1ms
HighSpeedCounter
MaxFreq 500kHz
Digital Relay Outputs
OutputsperModule 6Relay
CommonsperModule 6
Max.OutputCurrent
perRelay 3A@250VAC,resistive
Max.TotalOutputCur-
rent 5Acontinuous
Max.OutputVoltage 275VAC,30VDC
Max.SwitchedPower 1000VAC,150W
ContactIsolationto
Ground 1000VAC
Max.VoltageDropat
RelatedCurrent 0.5V
ExpectedLife(see
belowderatingchart
fordetails)
No Load:5,000,000
Rated Load:100,000
Max.SwitchingRate 300CPMatnoload
20CPMatratedload
Type MechanicalContact
ResponseTime
Oneupdateper
ladderscanplus10ms
Analog Inputs, Medium Resolution
NumberofChannels 4
InputRanges 0-10VDC,0-20mA,4-20mA
SafeInputVoltage
Range -0.5Vto12V
InputImpedance
(clamped@-0.5VDC
to12VDC)
Current Mode:100Ω
Voltage Mode:500kΩ
NominalResolution 12Bits
%AIFullScale 0V, 20mA, 100mV:
32,000countsfullscale
Max.OverCurrent 35mA
ConversionSpeed OnceperLadderScan
MaxErrorat25˚C
(excludingZero)
AdjustingFiltering
mayTighten
4–20mA1.00%
0-20mA1.00%
0-10VDC1.50%
Filtering
160HzHash(noise)Filter,1-128
ScanDigitalRunningAverageFil-
ter

Wiring:Model 2
Page 5
WIRING: INPUTS AND OUTPUTS
Analog Inputs Information
Rawinputvaluesforchannels1-4arefoundintheregisters
asInteger-typedatawitharangefrom0–32000.
AnaloginputsmaybefiltereddigitallywiththeFilterCon-
stantfoundintheCscapeHardwareConfigurationforAna-
logInputs.Validfiltervaluesare0-7andactaccordingto
thefollowingchart:
Data Values
InputMode: DataFormat,12-bitINT:
0-20mA,4-20mA 0-32000
0-10V 0-32000
Digital Inputs
DigitalinputsmaybewiredineitheraPositiveLogicorNeg-
ativeLogicfashionasshown.ThesettingintheCscape
HardwareConfigurationfortheDigitalInputsmustmatch
thewiringusedinorderforthecorrectinputstatestobe
registered.NojumpersettingsarerequiredforXLEe/XLTe.
Whenusedasanormalinputandnotforhighspeedfunc-
tions,thestateoftheinputisreflectedinregisters%I1–
%I12.
Relay Life
WARNING:Exposuretosomechemicalsmaydegradethe
sealingproper-tiesofmaterialsusedintheTycorelayPCJ.
Cover/Case & Base:MistubishiengineeringPlasticsCorp.
5010GN6-30or5010GN6-30M8(PBT)
Sealing Material:Kishimoto4616-50K(Ipartepoxyresin)
Jumper Settings for Model 2
LocationofI/Ojumpers(JP1&JP2)andwiringconnectors
(J1&J2)withbackcoverremoved.
NOTE:TheCscapeModuleConfigurationmustmatchthe
selectedI/O(JP)jumpersettings.
NOTE:WhenusingJP2(A1-A4),eachchannelcanbeinde-
pendentlyconfigured.
Back Panel Torque Ratings
XLE/XLT:3.0-4.0in-lbs(0.34-0.45N-m)
XL4/XL4 Prime:3.0-4.0in-lbs(0.34-0.45N-m)
EXL6/XL6 Prime:3.0-4.0in-lbs(0.34-0.45N-m)
EXLW/ XLW Prime:3.0-3.5in-lbs(0.34-0.40N-m)
XL7/XL7 Prime:3.0-3.5in-lbs(0.34-0.40N-m)
EXL10/XL10 Prime:3.0-3.5in-lbs(0.34-0.40N-m)

Wiring:Model 2
Page 6
J1 Wiring - Digital In / Analog In
NOTE:The0Vterminalsareinternallyconnected.
J2 Wiring - Relay Out / Analog or
Digital In
Wiring Details
Solid/Stranded Wire:12-24awg(2.5-0.2mm2).
Strip Length:0.28”(7mm).
Torque, Terminal Hold-Down Screws:4.5–7in-lbs
(0.50–0.78N-m).
BUILT-IN I/O
TheI/OismappedintoOCSRegisterspace,inthreesep-
arateareas–Digital/AnalogI/O,High-SpeedCounterI/O,
andHigh-speedOutputI/O.Digital/AnalogI/Olocationis
fixedstartingat1,butthehigh-speedcounterandhigh-
speedoutputreferencesmaybemappedtoanyopen
registerlocation.
Digital and Analog I/O Functions
DigitalInputs %I1-12
Reserved %I13-32
ESCPAlarm n/a
DigitalOutputs %Q1-6
Reserved %Q7-24
AnalogInputs %AI1-4
Reserved %AI5-12
AnalogOutputs n/a
Reserved n/a
Analog Input Tranzorb Failure
AcommoncauseofAnalogInputTranzorbFailureonAna-
logInputsModel2,3,4&5:Ifa4-20mAcircuitisinitially
wiredwithlooppower,butwithoutaload,theanaloginput
couldsee24VDC.Thisishigherthantheratingofthetran-
zorb.ThiscanbesolvedbyNOTconnectinglooppower
priortoloadconnection,orbyinstallingalow-costPTCin
seriesbetweentheloadandanaloginput.

Page 7
COMMUNICATIONS
Serial Communication
MJ1 Wiring
RS-232withfullhandshakingorRS-485half-
duplex
RS-485terminationviaswitches;biasingviasoft-
ware
MJ1 Pins
PIN SIGNAL DIRECTION
8 TXD OUT
7 RXD IN
6 0V GROUND
5 +5V@60mA OUT
4 RTS OUT
3 CTS IN
2 RX-/TX- IN/OUT
1 RX+/TX+ IN/OUT
MJ2 Wiring
RS-232orRS-485halforfull-duplex,software
selectable
RS-485terminationviaswitches;biasingvia
software
MJ2 Pins
PIN SIGNAL DIRECTION
8 232TXD OUT
7 232RXD IN
6 0V GROUND
5 +5V@60mA OUT
4 485TX- OUT
3 485TX+ IN
2 485RX-orRX/TX- INorIN/OUT
1 485RX+orRX/TX+ INorIN/OUT
NOTE:Attachoptionalferritecorewithaminimumoftwo
turnsofserialcable.
Ethernet
Green LED indicates link-whenillu-
minated,datacommunicationisavailable.
Yellow LED indicates activity-when
flashing,dataisintransmission.
CAN Communications
CAN Pin Assignments
PIN SIGNAL DESCRIPTION
1 V- CANGround–Black
2 CN_L CANDataLow–Blue
3 SHLD ShieldGround–None
4 CN_H CANDataHigh–White
5 V+(NC) NoConnect–Red
lSolid/Stranded Wire:12-24awg(2.5-0.2mm).
lStrip Length:0.28”(7mm).
lLockingspring-clamp,two-terminatorspercon-
ductor.
lTorque, Terminal Hold-Down Screws:4.5–7in-
lbs(0.50–0.78N-m).
lV+pinisnotinternallyconnected,theSHLDpinis
connectedtoEarthgroundviaa1MΩresistorand10
nFcapacitor.
Dip Switches
DIP Switches
PIN NAME FUNCTION DEFAULT
1MJ1RS-485
Termination
ON=Ter-
minated OFF
2MJ2RS-485
Termination
ON=Ter-
minated OFF
3 Bootload AlwaysOff OFF
TheDIPswitchesareusedtoprovideabuilt-intermination
toboththeMJ1portandMJ2portifneeded.Theter-
minationfortheseportsshouldonlybeusedifthisdeviceis
locatedateitherendofthemultidrop/daisy-chainedRS-
485network.

Page 8
DIMENSIONS & INSTALLATION
Dimensions & Panel Cutout
Installation Information
lTheXLE/XLTutilizesaclipinstallationmethodto
ensurearobustandwatertightsealtotheenclosure.
Pleasefollowthestepsbelowfortheproperinstall-
ationandoperationoftheunit.
lThisequipmentissuitableforClassI,Division2,
GroupsA,B,CandDornon-hazardouslocations
only.
lDigitaloutputsshallbesuppliedfromthesame
sourceastheoperatorcontrolstation.
lJumpersonconnectorJP1shallnotberemovedor
replacedwhilethecircuitisliveunlesstheareais
knowntobefreeofignitableconcentrationsofflam-
mablegasesorvapors.
lWARNING-TheUSBportsareforoperationalmain-
tenanceonly.Donotleavepermanentlyconnected
unlessareaisknowntobenon-hazardous.
Installation Procedure
1. Carefullylocateanappropriateplacetomountthe
XLE/XLT.Besuretoleaveenoughroomatthetopof
theunitforinsertionandremovalofthemicroSD™
card.
2. Carefullycutthehostpanelperthediagram,cre-
atinga92mmx92mm+/-0.1mmopeningintowhich
theXLE/XLTmaybeinstalled.Iftheopeningistoo
large,watermayleakintotheenclosure,potentially
damagingtheunit.Iftheopeningistoosmall,the
OCSmaynotfitthroughtheholewithoutdamage.
3. Removeanyburrsandorsharpedgesandensure
thepanelisnotwarpedinthecuttingprocess.
4. RemoveallRemovableTerminalsfromthe
XLE/XLT.InserttheXLE/XLTthroughthepanel
cutout(fromthefront).Thegasketmustbebetween
thehostpanelandtheXLE/XLT.
5. Installandtightenthefourmountingclips(provided
inthebox)untilthegasketformsatightseal(NOTE:
Maxtorque0.8to3Nm,or7-10in-lbs).
6. ReinstalltheXLE/XLTI/ORemovableTerminal
Blocks.Connectcommunicationscablestothe
serialport,USBports,Ethernetport,andCANport
asrequired.
Battery Maintenance
TheXLE/XLTusesareplaceablenon-rechargeable3VLith-
iumcoincellbattery(CR2450)toruntheReal-TimeClock
andtokeeptheretainedregistervalues.Thisbatteryis
designedtomaintaintheclockandmemoryfor7to10
years.PleasereferenceMAN0878providinginstructions
onhowtoreplacethebattery.

Page 9
SAFETY & MAINTENANCE
Warnings
1. Toavoidtheriskofelectricshockorburns,alwayscon-
nectthesafety(orearth)groundbeforemakinganyother
connections.
2. Toreducetheriskoffire,electricalshock,orphysical
injury,itisstronglyrecommendedtofusethevoltage
measurementinputs.Besuretolocatefusesascloseto
thesourceaspossible.
3. Replacefusewiththesametypeandratingtoprovidepro-
tectionagainstriskoffireandshockhazards.
4. Intheeventofrepeatedfailure,doNOTreplacethefuse
againasrepeatedfailureindicatesadefectivecondition
thatwillNOTclearbyreplacingthefuse.
5. Onlyqualifiedelectricalpersonnelfamiliarwiththecon-
structionandoperationofthisequipmentandthehazards
involvedshouldinstall,adjust,operate,orservicethis
equipment.
6. Readandunderstandthismanualandotherapplicable
manualsintheirentiretybeforeproceeding.Failureto
observethisprecautioncouldresultinseverebodilyinjury
orlossoflife.
7. WARNING-Batterymayexplodeifmistreated.Donot
recharge,disassemble,ordisposeofinfire.
8. WARNING - EXPLOSION HAZARD-Batteriesmustonly
bechangedinanareaknowntobenon-hazardous.
9. WARNING-Donotdisconnectwhilecircuitisliveunless
areisknowtobenon-hazardous.
FCC Compliance
ThisdevicecomplieswithPart15oftheFCCRules.Operationis
subjecttothefollowing
twoconditions:
1. Thisdevicemaynotcauseharmfulinterference.
2. Thisdevicemustacceptanyinterferencereceived,includ-
inginterferencethatmaycauseundesiredoperation.
Technical Support
North America
1(317)916-4274
(877)665-5666
www.hornerautomation.com
Europe
+353(21)4321-266
www.hornerautomation.eu
Precautions
Allapplicablecodesandstandardsneedtobefollowedinthe
installationofthisproduct.Adheretothefollowingsafetypre-
cautionswheneveranytypeofconnectionismadetothemodule:
1. Connectthesafety(earth)groundonthepowerconnector
firstbeforemakingany
2. otherconnections.
3. Whenconnectingtotheelectriccircuitsorpulse-initiating
equipment,opentheir
4. relatedbreakers.
5. DoNOTmakeconnectiontolivepowerlines.
6. Makeconnectionstothemodulefirst;thenconnecttothe
circuittobemonitored.
7. Routepowerwiresinasafemannerinaccordancewith
goodpracticeandlocalcodes.
8. Wearproperpersonalprotectiveequipmentincluding
safetyglassesandinsulatedgloveswhenmakingcon-
nectionstopowercircuits.
9. Ensurehands,shoes,andflooraredrybeforemakingany
connectiontoapowerline.
10. MakesuretheunitisturnedOFFbeforemakingcon-
nectiontoterminals.
11. Makesureallcircuitsarede-energizedbeforemakingcon-
nections.
12. Beforeeachuse,inspectallcablesforbreaksorcracksin
theinsulation.Replace
13. immediatelyifdefective.
14. UsecopperconductorsinFieldWiringonly,60/75˚C.
15. UsecautionwhenconnectingcontrollerstoPCsviaserial
orUSB.PCs,especiallylaptops,mayuse“floatingpower
supplies”thatareungrounded.Thiscouldcauseadam-
agingvoltagepotentialbetweenthelaptopandcontroller.
Ensurethecontrollerandlaptoparegroundedformax-
imumprotection.ConsiderusingaUSBisolatordueto
voltagepotentialdifferencesasapreventativemeasure.
This manual suits for next models
11
Table of contents
Other HORNER Controllers manuals

HORNER
HORNER XL6 Prime Instruction Manual

HORNER
HORNER XLW PRIME User manual

HORNER
HORNER HE-XPC1E2 User manual

HORNER
HORNER XL Series User manual

HORNER
HORNER XL4 User manual

HORNER
HORNER XLE Use and care manual

HORNER
HORNER XL4 6 User manual

HORNER
HORNER RCC Series User manual

HORNER
HORNER ZX Series User manual

HORNER
HORNER XL6 Series User manual
Popular Controllers manuals by other brands

SOMFY
SOMFY WISNIOWSKI Metro 800 RTS installation manual

WAREMA
WAREMA KNX SA 16M230.32 SMI AP installation instructions

Norac
Norac UC4+ installation manual

TEL
TEL AFA4000/1/AS Installation and calibration guide

Fireye
Fireye BurnerPRO BP110 manual

Bosch
Bosch EasyControl CT200 Installation and operating instructions