1. Technical Specifications
Product type Dual sense DALI sensor ( HF and PIR, Tri-level control )
Operating voltage 9.5~22.5VDC (suitable DALI power supply)
Input current Approx.12mA
Power consumption 0.25W
Detection angle 360o
Detection area (DxH) 12 x 6m (Maximum)
Mounting height 6m (Maximum)
Detection range 10% / 50% / 75% / 100%
Hold time 2s / 30s / 1min / 5min / 10min / 15min / 20min / 30min
Stand-by time 0s / 10s / 1min / 5min / 10min / 30min / 1h / +∞
Stand-by dimming level 10% / 20% / 30% / 50%
Daylight threshold 2Lux /10Lux / 50Lux / Disable
Warmming up time 30s
Operating temperature -20oC ~ +50oC
Sensor mode PIR, HF, PIR+HF, PIR / HF
3. Rotary Switch Settings
A rotary switch is built inside the sensor for
scene selection / fast programming. Total
16 channels available:
Note: settings can also be changed by remote control HRC-11. The last action controls.
SURFACE MOUNT DUAL SENSE DALI SENSOR HIM13
Rotary switch preset (Please
see the location in 2. Installation)
Detection
range
Channel
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
75%
50%
100%
100%
100%
5s
1min
5min
5min
5min
5min
5min
10min
10min
10min
10min
10min
10min
30min
30min
5s
10s
5min
10min
30min
0s
+∞
+∞
10min
30min
+∞
+∞
+∞
+∞
+∞
+∞
10s
10%
10%
10%
10%
Disable
10%
30%
10%
10%
10%
30%
10%
10%
10%
30%
10%
Disable
2Lux
10Lux
30Lux
10Lux
30Lux
Disable
2Lux
10Lux
30Lux
Disable
30Lux
10Lux
50Lux
Disable
2Lux
Hold
time
Stand-by
time
Stand-by
dimming level
Daylight
threshold
4. Sensor Mode Selection
Sensor mode can be easily selected by choosing the correct combination of the DIP switches
(see table below):
HIM13-20190104-A1
HF
PIR
HF+PIR
HF/PIR
1 2
I
II
III
IV
DALI group selection (Please
see the location in 2. Installation)
5. DALI group selection
DALI group configuration can be done on PC or on the rotary switch:
1. There are 16 channels available on the rotary switch. “0” is
for DALI broadcast, the rest 15 channels is for end user to
define the application unit.
2. PC grouping can overwrite rotary switch grouping, and vise
versa. The last setting controls.
Switch channel DALI group Switch channel DALI group
0
1
2
3
4
5
6
7
broadcast
group 0
group 1
group 2
group 3
group 4
group 5
group 6
8
9
A
B
C
D
E
F
group 7
group 8
group 9
group 10
group 11
group 12
group 13
group 14
HF+PIR: Light is on when both HF
and PIR sensors are activated.
HF/PIR: Light is on when HF or PIR
sensors are activated.
Installation and Instruction Manual
TM
2. Installation
Warnings:
1. Installation must be carried out by a
qualified engineer in accordance with
local regulations.
2. Disconnect supply before installing.
3. Install to a solid surface - vibrations may
cause mis-triggering.
4. Ensure environmental conditions are
suitable for electronic equipment
Direct junction “J” box mounting
a. Separate control board (A) from facia (B)
& junction box (C).
b. Make electrical connections to control board
(A). See detailed wiring diagram on next page.
c. Secure control board (A) to junction box.
d. Set-up sensor modes as per sections 3 & 4
of this manual.
e. Clip facial plate (B) to control board (A).
Surface mount assembly
a. Separate control board (A) from facia (B) &
Surface box (C).
b. Securely mount surface box (C) to a flat and
solid surface.
c. Make electrical connections to control board
(A). See detailed wiring diagram on next page.
d. Set-up sensor modes as per sections 3 & 4 of
this manual.
e. Secure control board (A) to surface box (C).
f. Clip facial plate (B) to control board (A).
The rotary switch channel is corresponding to the groups listed below:
Infrared receiver
HF Sensor module
Photocell
PIR
LED indicator
Sensor mode selection
Rotary switch preset
DALI group selection
A - Control Board
29
56
50.2
55.2
109
38.6
56
A
56
A
BB
CC
Blind
A
B
Blind
Note: the blinds are optional, they may be inserted behind the lens for focussing the detection range.
C - Surface box
B - Facia Cover
11
43.5
64.7
69.1
PIR
HF
PIR tangential movement 10m
HF walking across 8m
3m
PIR
HF
B
4m
HF walking across 8m
PIR tangential movement 10m
3m
PIR
HF
A
3m
HF walking across 8m
PIR tangential movement 5m
HIM13-20190104-A1
6. Functions
Hytronik builds this function inside the motion sensor to achieve tri-level control, for some areas require a
light change notice before switch-off.
It offers 3 levels of light: 100%-->dimmed light-->off; and 2 periods of selectable waiting time: motion
hold-time and stand-by period; Selectable daylight threshold and freedom of detection area.
This DALI sensor is designed for incoporating in the DALI system, taking command from the DALI master,
accepting and carrying out the grouping work. It can switch on/off, or dim the assigned group members
and feed back the status to the DALI master. With the rotary coding switch, it is easy to be added into the
existing DALI system, and do the grouping work without the help of the DALI master and computer
interface. More details please refer to section 5. DALI grouping selection.
By connecting the DALI terminals in parallel (see wiring diagram), no matter which sensor detects
motion, all HIM13 in the group will turn on the lights when surrounding natural light is below the
daylight threshold. The sensor antenna is shared and the detection area could be widely enlarged in
this way.
6.1 Tri-level Control (Corridor Function)
6.2 Synchronization Function
Hytronik Industrial Ltd. | www.hytronik.com
3rd Floor, block C, complex building, 155#, Bai'gang road south,
Bai'gang village, Xiao Jin Kou town, Huicheng district, Huizhou 516023
Tel: 86-752-2772020 Fax: 86-752-2777877
Description of the
Button Functions
(remote control HRC-11)
9.
HRC-11
6
8
10
11
12
13
14
2
4
1
3
7
9
5
Permanent ON/OFF [ ]
Press button to select permanent ON or permanent OFF mode.
* Press button / to resume automatic operation.
The mode will change to AUTO Mode after power failure.
Power output [ button ]
All buttons in zone are disabled.
button
Auto Mode [ button ]
Brightness +/- [ button ]
All buttons in zone are disabled.
Scene prog. [ zone ] (One-key-commissioning)
Shift [ button ]
RESET [ button ]
Press button , all settings go back to the rotary switch settings.
Sensor mode return to DIP switches settings.
Press button to initiate automatic mode. The sensor starts working
and all settings remain as before the light was switched ON/OFF.
Note: the function of Semi-auto is disabled.
1. Press button “Start” to program.
2. Select the buttons in “Detection range”, / “Daylight threshold”,
“Hold time”, “Stand-by time”, “Stand-by dimming level” to
set all parameters.
3. Press button “Memory” to save all the settings programmed in the
remote control.
4. Press button “Apply” to set the settings to each sensor unit(s).
For example, to pre-set detection range 100%, daylight threshold
Disable, hold time 5min, stand-by time +∞, stand-by dimming level
30%, steps should be:
Press button Start, button 100%, Disable, Shift, 5min,
Shift, +∞ , 30%, Memory. By pointing to the sensor unit(s)
and pressing Apply, all settings are passed on the sensor(s).
Press button , the LED on the top left corner flashes for indication.
All values / settings in RED are in valid for 20 seconds.
1
2
2
3
3
4
4
5
6
7
7
7
7
3
3
8
8 9
10
10 11
1312
11 12 13
6
5
1
2 4
Ambient daylight threshold [ button ]
Detection range [ zone ]
Press buttons in zone to set HF detection range at 100% / 75% /
50% / 10%.
Stand-by time [ zone ]
Press buttons in zone to set the stand-by period at 0s / 10s /
1min / 5min / 10min / 30min / 1h / +∞.
Note: “0s” means on/off control; “+∞” means bi-level control, 100%
on when motion detected, and remains at the stand-by
dimming level when no presence after hold-time.
Daylight threshold [ zone ]
Press buttons in zone to set the daylight sensor at 2Lux / 10Lux /
50Lux / Disable.
Note: 100Lux / 300Lux / 500Lux are disabled.
1. Press button Shift, the red LED flashes for indication.
2. Press button , the ambient lux level is sampled and set as the
new daylight threshold.
Hold time [ zone ]
Press buttons in zone to set the hold time at 2s / 30s / 1min /
5min / 10min / 15min / 20min / 30min.
Note: 1.To set hold-time at 30s / 5min / 15min / 30min, press button
Shift at first.
2. 2s is for test purpose only, stand-by period and daylight
sensor settings are disabled in this mode.
* To exit from Test mode, press button or any button in zone .
Stand-by dimming level [ zone ]
Press buttons in zone to set the stand-by dimming level at 10% /
20% / 30% / 50%.
Dual tech & RF mode [ zone ]
1. Press buttons in zone to select sensor technology.
HF+PIR: Light is on when both HF and PIR sensors are activated.
HF/PIR: Light is on when HF or PIR sensors are activated.
2. Learn / Erase, Transmit, RX100% and RX STBY% are disabled.
8
3
3
2
9
10
11
12
13
14
14
13
12
11
11
10
9
8
&
A
4
4 hhh
Note:the function of 24h /12h /4h /30s are disabled.
7. Wiring Diagram
Detection Pattern8.
L
N
DALI power
supply DALI
driver
Bus-mastering
DALI master
DALI
driver DA1 DA2 DA1 DA2
HIM13HIM13

Other Hytronik Accessories manuals

Hytronik HIM32 Quick guide

Hytronik

Hytronik HIM32 Quick guide

Hytronik HC028V/RF User manual

Hytronik

Hytronik HC028V/RF User manual

Hytronik HEC7430 User manual

Hytronik

Hytronik HEC7430 User manual

Hytronik HIM39/RF Quick guide

Hytronik

Hytronik HIM39/RF Quick guide

Hytronik HC005S/BT Quick guide

Hytronik

Hytronik HC005S/BT Quick guide

Hytronik HEC7428 User manual

Hytronik

Hytronik HEC7428 User manual

Hytronik HIR23/D2 Quick guide

Hytronik

Hytronik HIR23/D2 Quick guide

Hytronik DUAL sense HIM11 Quick guide

Hytronik

Hytronik DUAL sense HIM11 Quick guide

Hytronik HC407VDS User manual

Hytronik

Hytronik HC407VDS User manual

Hytronik HIR23 Quick guide

Hytronik

Hytronik HIR23 Quick guide

Hytronik HMW34 Quick guide

Hytronik

Hytronik HMW34 Quick guide

Hytronik HMW34 Quick guide

Hytronik

Hytronik HMW34 Quick guide

Hytronik HEC7028 User manual

Hytronik

Hytronik HEC7028 User manual

Hytronik HMW32 User manual

Hytronik

Hytronik HMW32 User manual

Hytronik HIR24 User manual

Hytronik

Hytronik HIR24 User manual

Hytronik HC438V User manual

Hytronik

Hytronik HC438V User manual

Hytronik HC419VRC/R User manual

Hytronik

Hytronik HC419VRC/R User manual

Hytronik HC009S-KD/I Quick guide

Hytronik

Hytronik HC009S-KD/I Quick guide

Hytronik HIM38/RF User manual

Hytronik

Hytronik HIM38/RF User manual

Hytronik Dual Sense HIM15 User manual

Hytronik

Hytronik Dual Sense HIM15 User manual

Hytronik HMW12 Quick guide

Hytronik

Hytronik HMW12 Quick guide

Hytronik DualSense HIM11 Quick guide

Hytronik

Hytronik DualSense HIM11 Quick guide

Hytronik HMW30 Quick guide

Hytronik

Hytronik HMW30 Quick guide

Hytronik HBHC25 Quick guide

Hytronik

Hytronik HBHC25 Quick guide

Popular Accessories manuals by other brands

Airzone FLEXA 3.0 IBPRO6 Assembly instructions

Airzone

Airzone FLEXA 3.0 IBPRO6 Assembly instructions

BD Sensors DMK 457 operating manual

BD Sensors

BD Sensors DMK 457 operating manual

EL EL-4601 quick start guide

EL

EL EL-4601 quick start guide

Seebacher ISYGLT LSR-02 instruction manual

Seebacher

Seebacher ISYGLT LSR-02 instruction manual

zilink HD Series user manual

zilink

zilink HD Series user manual

Philio PAT12-A quick start guide

Philio

Philio PAT12-A quick start guide

AKIBA SLX-26AL manual

AKIBA

AKIBA SLX-26AL manual

POLTI SANI SYSTEM manual

POLTI

POLTI SANI SYSTEM manual

Honeywell Lyric RF6PIR installation instructions

Honeywell

Honeywell Lyric RF6PIR installation instructions

Bogen IKS9 quick start guide

Bogen

Bogen IKS9 quick start guide

Omron FQ-CR2 Series instruction sheet

Omron

Omron FQ-CR2 Series instruction sheet

Juice 1 quick start guide

Juice

Juice 1 quick start guide

KUNK 1601 user manual

KUNK

KUNK 1601 user manual

GE CPLGSTDBLW1 install guide

GE

GE CPLGSTDBLW1 install guide

aci IMMERSION SERIES Installation & operation instructions

aci

aci IMMERSION SERIES Installation & operation instructions

Bogen ANS1R instruction manual

Bogen

Bogen ANS1R instruction manual

Ambient Weather WH31SM manual

Ambient Weather

Ambient Weather WH31SM manual

Reer 29020 Instructions for use

Reer

Reer 29020 Instructions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.