manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Hytronik
  6. •
  7. Accessories
  8. •
  9. Hytronik HIR23/D2 Quick guide

Hytronik HIR23/D2 Quick guide

Installation and Instruction Manual
2. Installation
1. Ceiling (drill hole φ66~68mm)
2. Carefully prise off the cable clamps.
3. Make connections to the pluggable
terminal blocks.
4. Insert plug connectors and secure using
the provided cable clamps, then clip
terminal covers to the base.
5. Fit detection blind (if required) and
desired lens.
6. Clip fascia to body.
7. Bend back springs and insert into ceiling.
Mechanical Structure & Dimensions
HIR23/D2 HIR23/D2/R
HIR23/D2/W HIR23/D2/H HIR23/D2/RH
HIR23/D2-20220106-A0
1. Technical Specifications
PIR Motion Sensor
DALI
5
* Install blind as required
A B
6
7
75.2
70.5
62.2
Ø 78
4
2
3
1
Ø 66~68mm
* Install lens as required
1 2 3
EMC standard (EMC)
DALI
Certification
EN55015, EN61000, EN61547
CE , REACH, UKCA, RCM, ROHS
compliance
IEC60386-101, 103, 303, 304
RED EN300328, EN301489-1/-17
Operation temperature
Ta: -20
ºC
~ +50
ºC
IP20IP rating
Operating voltage
Red LED flashes 15SIdentify device
5sWarming-up
9.5~22.5VDC
Consumption DALI
BUS current
Max. 10 mA(no LED)
Max. 12 mA(with LED)
< 1000 lux
360º
PIR detectionSensor Model
HIR23/D2/H
Lux reading range
Detection angle
Installation height:15m (forklift)
12m (person)
Detection range (Ø):24m
HIR23/D2
Installation Height : 6m
Detection Range(Ø) :9m
HIR23/D2/R
Installation Height : 6m
Detection Range(Ø) :10m
HIR23/D2/RH
Installation height:20m (forklift)
12m (person)
Detection range (Ø):40m
HIR23/D2/W
Installation Height : 6m
Detection Range(Ø) :18m
HIR23/D2-20220106-A0
Subject to change without notice.
Wire Preparation
Pluggable screw terminal. It is recommended to make
connections to the terminal before fitting to the sensor.
0.75 - 2.5mm
7-8mm
Wiring Diagram
N
L
DALI Driver
DALIDALI
HIR23/D2
DALI power
supply
DALI Driver
DALI-2 Multi-Master-
Application-Controller
Note: HIR23/D2 has been used as DALI-2 input device to only report DALI instance (light sensor instance and motion sensor instance) to DALI-2 application controller, who is the “main brain” to process the
data communication between input devices and the control gear and assign different function.
Big and small silicon gasket used to make IP65 degree protection when HIR23/D2 series device mounted into HA03 housing for ceiling mount
small silicon water-proof gasket dimension(size:mm) big silicon water-proof gasket dimension(size:mm)
HIR23/D2-20220106-A0
Subject to change without notice.
3. Detection Pattern & Optional Accessories
Radial (B)
Tangential (A)
2.5m
Mount height
6m
5m
4m
3m
insensitive sensitive insensitive sensitive
A: Tangential movement
Tangential: max. 9m
h = max.6m
A
B: Radial movement
Radial: max. 4m
h = max.6m
B
HIR23/D2: Low-bay flat lens detection pattern for single person @ Ta = 20ºC
(Recommended ceiling mount installation height 2.5m-6m)
max 64m
2
(Ø = 9m) max 13m
2
(Ø = 4m)
max 13m
2
(Ø = 4m)
max 13m
2
(Ø = 4m)
max 13m
2
(Ø = 4m)
max 13m
2
(Ø = 4m)
max 50m
2
(Ø = 8m)
max 38m
2
(Ø = 7m)
max 38m
2
(Ø = 7m)
max 38m
2
(Ø = 7m)
Optional Accessory --- Ceiling/Surface Mount Box: HA03
1. HIR23/D2 (Low-bay)
Valid Range
Blind Option 1 --- Aisle Detection
Optional Accessory --- Blind Insert for Blocking Certain Detection Angles
75
Ø 94
Blind Option 2 --- 180º Detection
Valid Range
44
66
4.2
HIR23/D2-20220106-A0
Subject to change without notice.
Radial (B)
Tangential (A)
2.5m
Mount height
6m
5m
4m
3m
HIR23/D2/R: Low-bay convex lens detection pattern for single person @ Ta = 20ºC
(Recommended ceiling mount installation height 2.5m-6m)
max 79m
2
(Ø = 10m)
max 79m
2
(Ø = 10m)
max 64m
2
(Ø = 9m)
max 50m
2
(Ø = 8m)
max 50m
2
(Ø = 8m)
max 20m
2
(Ø = 5m)
max 20m
2
(Ø = 5m)
max 20m
2
(Ø = 5m)
max 20m
2
(Ø = 5m)
max 20m
2
(Ø = 5m)
2. HIR23/D2/R (Reinforced Low-bay)
A: Tangential movement
Tangential: max. 10m
h = max.6m
A
B: Radial movement
Radial: max. 5m
h = max.6m
B
Optional Accessory --- Ceiling/Surface Mount Box: HA03
Optional Accessory --- Blind Insert for Blocking Certain Detection Angles
75
Ø 94
Valid Range
Blind Option 1 --- Aisle Detection Blind Option 2 --- 180º Detection
Valid Range
insensitive sensitive insensitive sensitive
44
66
4.2
HIR23/D2-20220106-A0
Subject to change without notice.
Radial (B)
Tangential (A)
2.5m
Mount height
6m
5m
4m
3m
HIR23/D2/W: Low-bay convex lens detection pattern for single person @ Ta = 20ºC
(Recommended ceiling mount installation height 2.5m-6m)
max 254m² (Ø = 18m)
max 254m² (Ø = 18m)
max 154m² (Ø = 14m)
max 113m² (Ø = 12m)
max 79m² (Ø = 10m)
max 28m² (Ø = 6m)
max 28m² (Ø = 6m)
max 28m² (Ø = 6m)
max 28m² (Ø = 6m)
max 13m² (Ø = 4m)
3. HIR23/D2/W (Wide range Low-bay)
A: Tangential movement
Tangential: max. 18m
h = max.6m
A
B: Radial movement
Radial: max. 6m
h = max.6m
B
Ceiling/Surface Mount Accessory HA03: Default IP20, IP65 can be request with extra big & small water-proof gaskets
75
Ø
94
insensitive sensitive insensitive sensitive
HIR23/D2-20220106-A0
Subject to change without notice.
4. HIR23/D2/H (High-bay)
Radial (B)
Tangential (A)
10m
Mount height
14m
15m
13m
12m
11m max 452m
2
(Ø = 24m)
max 380m
2
(Ø = 22m)
max 452m
2
(Ø = 24m)
max 452m
2
(Ø = 24m)
max 452m
2
(Ø = 24m)
max 452m
2
(Ø = 24m)
max 201m
2
(Ø = 16m)
max 201m
2
(Ø = 16m)
max 201m
2
(Ø = 16m)
max 177m
2
(Ø = 15m)
max 133m
2
(Ø = 13m)
max 113m
2
(Ø = 12m)
A: Tangential movement
Tangential: max. 24m
h = max.15m
A
B: Radial movement
Radial: max. 16m
h = max.15m
B
HIR23/D2/H: High-bay lens detection pattern for forklift @ Ta = 20ºC
(Recommended ceiling mount installation height 10m-15m)
insensitive sensitive insensitive sensitive
Blind Option 1 --- Aisle Detection Blind Option 2 --- 180º Detection
Tangential: max. 20m
h = max.12m
A
Radial: max. 3m
h = max.12m
B
Optional Accessory --- Ceiling/Surface Mount Box: HA03
Optional Accessory --- Blind Insert for Blocking Certain Detection Angles
Valid Range Valid Range
Radial (B)
Tangential (A)
2.5m
Mount height
11m
12m
10m
8m
6m max 104m
2
(Ø = 11.5m)
max 50m
2
(Ø = 8m)
max 154m
2
(Ø = 14m)
max 227m
2
(Ø = 17m)
max 269m
2
(Ø = 18.5m)
max 314m
2
(Ø = 20m)
max 7m
2
(Ø = 3m)
max 7m
2
(Ø = 3m)
max 7m
2
(Ø = 3m)
max 7m
2
(Ø = 3m)
max 7m² (Ø = 3m)
max 7m² (Ø = 3m)
A: Tangential movement B: Radial movement
HIR23/D2/H: High-bay lens detection pattern for single person @ Ta = 20ºC
(Recommended ceiling mount installation height 2.5m-12m)
insensitive sensitive insensitive sensitive
75
Ø 94
44
66
4.2
HIR23/D2-20220106-A0
Subject to change without notice.
4. Additional Information / Documents
Radial (B)
Tangential (A)
10m
Mount height
14m
15m
13m
12m
11m
max 907m
2
(Ø = 34m)
max 962m
2
(Ø = 35m)
max 1075m
2
(Ø = 37m)
max 660m
2
(Ø = 29m)
max 346m
2
(Ø = 21m)
max 1256m
2
(Ø = 40m)
max 154m
2
(Ø = 14m)
max 177m
2
(Ø = 15m)
max 177m
2
(Ø = 15m)
max 154m
2
(Ø = 14m)
max 113m
2
(Ø = 12m)
max 113m
2
(Ø = 12m)
HIR23/D2/RH: Reinforced high-bay lens detection pattern for forklift @ Ta = 20ºC
(Recommended ceiling mount installation height 10m-15m)
5. HIR23/D2/RH (Reinforced High-bay with 3-Pyro)
A: Tangential movement
Tangential: max. 40m
h = max.20m
A
insensitive sensitive
B: Radial movement
Radial: max. 15m
h = max.20m
B
insensitive sensitive
Tangential: max. 30m
h = max.12m
A
Radial: max. 4m
h = max.12m
B
Radial (B)
Tangential (A)
2.5m
Mount height
11m
12m
10m
8m
6m max 154m
2
(Ø = 14m)
max 38m
2
(Ø = 7m)
max 314m
2
(Ø = 20m)
max 531m
2
(Ø = 26m)
max 615m
2
(Ø = 28m)
max 707m
2
(Ø = 30m)
max 7m
2
(Ø = 3m)
max 7m
2
(Ø = 3m)
max 7m
2
(Ø = 3m)
max 13m
2
(Ø = 4m)
max 13m
2
(Ø = 4m)
max 13m
2
(Ø = 4m)
A: Tangential movement B: Radial movement
HIR23/D2/RH: Reinforced high-bay lens detection pattern for single person @ Ta = 20OC
(Recommended ceiling mount installation height 2.5m-12m)
insensitive sensitive insensitive sensitive
Optional Accessory --- Ceiling/Surface Mount Box: HA03
75
Ø 94
44
66
4.2
20m max 707m2 (Ø = 30m) max 113m2 (Ø = 12m)
1. Regarding precautions for PIR Sensors installation and operation, please kindly refer to www.hytronik.com/download ->knowledge ->PIR Sensors - Precautions for Product Installation and Operation
2. Data sheet is subject to change without notice. Please always refer to the most recent release on www.hytronik.com/products/Motion Sensors ->Stand-alone Sensors
3. Regarding Hytronik standard guarantee policy, please refer to www.hytronik.com/download ->knowledge ->Hytronik Standard Guarantee Policy

This manual suits for next models

4

Other Hytronik Accessories manuals

Hytronik HMW14 Quick guide

Hytronik

Hytronik HMW14 Quick guide

Hytronik DS05 Quick guide

Hytronik

Hytronik DS05 Quick guide

Hytronik HC419VRC/DH Quick guide

Hytronik

Hytronik HC419VRC/DH Quick guide

Hytronik HMW14 Quick guide

Hytronik

Hytronik HMW14 Quick guide

Hytronik HC028V/RF User manual

Hytronik

Hytronik HC028V/RF User manual

Hytronik HMW21 Quick guide

Hytronik

Hytronik HMW21 Quick guide

Hytronik HIR32 Quick guide

Hytronik

Hytronik HIR32 Quick guide

Hytronik HC403VRC-KD User manual

Hytronik

Hytronik HC403VRC-KD User manual

Hytronik HIR23 Quick guide

Hytronik

Hytronik HIR23 Quick guide

Hytronik DUAL Sense HIM13 Quick guide

Hytronik

Hytronik DUAL Sense HIM13 Quick guide

Hytronik HC428V/RF User manual

Hytronik

Hytronik HC428V/RF User manual

Hytronik HC005S/BT Quick guide

Hytronik

Hytronik HC005S/BT Quick guide

Hytronik HIM34 Quick guide

Hytronik

Hytronik HIM34 Quick guide

Hytronik HMW20 Quick guide

Hytronik

Hytronik HMW20 Quick guide

Hytronik HIM32 Quick guide

Hytronik

Hytronik HIM32 Quick guide

Hytronik HCD418 User manual

Hytronik

Hytronik HCD418 User manual

Hytronik HC404VRC-KD User manual

Hytronik

Hytronik HC404VRC-KD User manual

Hytronik HIM31 Quick guide

Hytronik

Hytronik HIM31 Quick guide

Hytronik HC407VDS User manual

Hytronik

Hytronik HC407VDS User manual

Hytronik HC038V User manual

Hytronik

Hytronik HC038V User manual

Hytronik HMW15 Quick guide

Hytronik

Hytronik HMW15 Quick guide

Hytronik HIM38/RF User manual

Hytronik

Hytronik HIM38/RF User manual

Hytronik HIR28 Quick guide

Hytronik

Hytronik HIR28 Quick guide

Hytronik HIM31 Quick guide

Hytronik

Hytronik HIM31 Quick guide

Popular Accessories manuals by other brands

Axor Brushed Nickel 41333820 Specification sheet

Axor

Axor Brushed Nickel 41333820 Specification sheet

QUEST ELITE Kensington Care and Instructions

QUEST ELITE

QUEST ELITE Kensington Care and Instructions

Vinotemp WINE-MATE WM-2520SSH Operation Care Installation Manual

Vinotemp

Vinotemp WINE-MATE WM-2520SSH Operation Care Installation Manual

Hama 176570 operating instructions

Hama

Hama 176570 operating instructions

Arista ALC-CMP-BT installation instructions

Arista

Arista ALC-CMP-BT installation instructions

75F A/DP2 Series Installation & operation instructions

75F

75F A/DP2 Series Installation & operation instructions

HP 930C user guide

HP

HP 930C user guide

Popp POPE700168 quick start guide

Popp

Popp POPE700168 quick start guide

Capital Play CAPITAL PRO MASTER installation manual

Capital Play

Capital Play CAPITAL PRO MASTER installation manual

CARBONE MMX-607R product manual

CARBONE

CARBONE MMX-607R product manual

Pepperl+Fuchs LUC-M10 Safety instructions

Pepperl+Fuchs

Pepperl+Fuchs LUC-M10 Safety instructions

CyberPower ENVIROSENSOR user manual

CyberPower

CyberPower ENVIROSENSOR user manual

Behringer Foot Controller FCV100 user manual

Behringer

Behringer Foot Controller FCV100 user manual

Garmin interstuhl S4.0 Quick start manual

Garmin

Garmin interstuhl S4.0 Quick start manual

PCB Piezotronics 378A06 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 378A06 Installation and operating manual

Bircher Reglomat PIR 22 operating instructions

Bircher Reglomat

Bircher Reglomat PIR 22 operating instructions

HBK HBM Bruel & Kjaer MCS10 Mounting instructions

HBK

HBK HBM Bruel & Kjaer MCS10 Mounting instructions

Carlon 3302T Instruction guide

Carlon

Carlon 3302T Instruction guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.