HIR28-20190326-A1
Description of the
Button Functions
(remote control HRC-11)
6.
Ambient daylight threshold [ button ]
1. Press button Shift, the red LED starts to flash.
2. Press button , the ambient lux level is sampled and set as
the new daylight threshold / target Lux level.
3
10
10
Detection range [ zone ]
8
RESET[ button ]
Press button , all settings go back to default values as below:
2
2
Shift [ button ]
Press button , the LED on the top left corner is on
selection. All values / settings in RED are in valid for 20 seconds.
3
3
Auto Mode [ button ]
Press button to initiate automatic mode. The sensor starts working
and all settings remain as before the light is switched ON/OFF.
4
4
Scene prog. [ zone ] (One-key-commissioning)
1. Press button “Start” to program.
2. Select the buttons in “Detection range”, / “Daylight threshold”,
“Hold time” to set all parameters.
3. Press button “Memory” to save all the settings programmed in the
remote control.
7
7
7
7
3
8
10 11
7
8 9
10
7
11
Brightness +/- [ button ]
6
Power output [ button ]
5
Semi-auto Mode [ button & ]
1. Press button Shift (the red LED is on for indication).
2. Press button to initiate semi-auto mode. The fixture is manually
on by push-switch and automatically off in semi-auto mode.
3
3
4
4
Permanent ON/OFF [ ]
Press button , to select permanent ON or permanent OFF mode.
* Press button / to to quit this mode.
The mode will change to AUTO Mode after power failure.
button
1
1
2 4
Daylight threshold [ zone ]
Press buttons in zone to set daylight sensor at 2Lux/ 10Lux /
50Lux / 100Lux / 300Lux / 500Lux / Disable.
Note: To set daylight sensor at 100Lux / 300Lux / 500Lux, press
Shift button first.
9
9
3
Hold time [ zone ]
Press buttons in zone to set the hold time at 2s / 30s / 1min /
5min / 10min / 15min / 20min / 30min.
Note: 1.To set hold-time at 30s / 5min / 15min / 30min, press button
Shift at first.
2. 2s is for test purpose only, stand-by period and daylight
sensor settings are disabled in this mode.
*To exit from Test mode, press button or any button in zone .
3
11
11
11
2
HRC-11
6
8
10
11
12
13
14
2
4
1
3
7
9
5
Hold-time 5min, daylight threshold Disabled
to indicate mode
These two buttons are disabled.
These two buttons are disabled.
These two buttons are disabled.
All buttons in zone “Stand-by time ”, “Stand-by dimming
level & Auto-config“, “Dual-tech & RF mode” are disabled.
Detection Pattern5.
Detection range with convex lens
Detection range with flat lens
Tangential movement 10m
Radial movement 5m
3m 3m
Tangential movement 5m
Radial movement 2.5m
8m
2m
3m
Tangential movement 9m
Radial movement 4m
3m 3m
Tangential movement 4.5m
Radial movement 2m
7m
2m
3m
Detection range with convex lens(Blind A)
Detection range with flat lens (Blind A)
Detection range with convex lens ( blind B)
Detection range with flat lens(blind B)
4. Press button “Apply” to set the settings to each sensor unit(s).
For example, to set detection range 100%, daylight threshold
Disable, hold time 5min, the steps should be:
Press button Start, button 100%, Disable, Shift, 5min,
Memory. By pointing to the sensor unit(s)
and pressing Apply, all settings are passed on the sensor(s).
&
A
4
4 hhh