NOTE:the high-frequency output of this sensor is <0.2mW;approximately just 1‰ of the transmission power of a mobile telephone or
the output of a microwave oven.
<0.2mW
800W(capacitive Load)
2~50LUX, disable
STAND-BY PERIOD: 0s, 10s-1h, +
WORKING TEMPERATURE:
∞
STAND-BY DIMMING LEVEL : 10% ~ 50%
Max. 12 meters in diameter, adjustable.
Approx. 0.8W
1.0
4
Nx2(neutral / 220-240VAC)
L (phase / 220-240VAC)
L’ (switched phase / output)
New advanced version Model No.:HC019V
The sensor works with a main voltage of 220-240VAC 50/60 Hz.100-120VAC version is available
on request.
Antenna module
Led indication
Detection area
Hold-time
Daylight threshold
Stand-by period
Stand-by dimming level
Daylight sensor
0-10V
output
Sync
Wiring of 1 sensor controls a group of ballast /driver.
HC019V
MAX.800w
LED DriverLED Driver LED Driver
+
<0.2mW
-35 ~ +70℃
SYNC (synchronization interface)
+ (1-10V “+” interface)
- (1-10V “-” interface)
3rd Floor, block C, complex building, 155#, Bai'gang road south,
Bai'gang village, Xiao Jin Kou town, Huicheng district, Huizhou 516023
Tel:86-752-2772020 F:86-752-2777877
E: [email protected] W:www.hytronik.com
CHINA FACTORY
Room D, 10/f, Tower A, Billion Center, 1 wang Kwong Road,
Kowloon Bay, Kowloon, Hongkong
T: 00852-35197525 F: 00852-30116936
E: [email protected]
HYTRONIK INDUSTRIAL LIMITED
I – 0s
II – 10s
III – 1min
IV – 5min
V – 10min
VI – 30min
VII – 1h
VIII – +∞
This is the time period you would like to keep at the low light output level before it is completely switched off in the long absence
of people.
Note: “0s” means on/off control; “+∞” means 2 steps of dimming control, fixture never switch off.
Stand-by period (corridor function)
1h
10min
30min
5min
1min
10s
3
21
+∞
0s
I
I I
III
IV
V
VI
VII
VIII
1.1 This sensor is suitable for indoor use, and is also designed for installation Max. 6m in height.
SECTION 2 SETTINGS
Detection Area:
This determines the effective range of the motion detector and is set by DIP switches at the sensor itself, refer to figure.
Note that reducing the sensitivity will also narrow the detection range.
The following settings are available:
Hold time:
This determines the time the fitting remains at 100% level on motion detection and is set with DIP switches at the sensor
itself, refer to figure. The walk test setting is useful when installing the fitting to establish correct operation and range.
The following settings are available:
Daylight sensor:
This setting holds off the 100% light output should there sufficient daylight and is set using DIP switches at the sensor, refer
to figure. The following settings are available:
*In disable mode the lamp(s) will always be on with motion detected and operate at 100% light output, even in bright daylight.
I – 100%
II – 75%
III – 50%
IV – 10%
I – 5S
II – 30S
III – 1min
IV – 5min
V – 10min
VI – 20min
VII – 30min
I – Disable
II – 50Lux
III – 10Lux
IV – 2Lux
50 %
75%
100 %
10%
21
I
I I
III
I V
3
21
30min
5s
30s
1min
5min
10min
20min
I
I I
III
I V
V
VI
VII
21
50Lux
10Lux
2 Lux
Disable
I
I I
III
IV
HC019V
MAX.800w
HC019V
MAX.800w
Wiring of multiple sensors control the same group of ballast /driver, any sensor is triggered, the luminaries
in the group light up.
LED Driver XLED Driver XLED Driver X
LED Driver Y LED Driver Y LED Driver Y
Do not connect the 1-10v terminals on driver X to Driver Y.
*
SECTION 4 TROUBLE SHOOTING
YDEMERESUACYDEMERESUACNOITCNUFLAM
The load will not work
gnittestsujdAdetcelesgnitteslortnoc-thgiltcerrocnI
daolecalpeRytluafdaoL
NOhctiwSFFOhctiwssniaM
gnittesenozkcehCenoznoitcetedehtnitnemevomsuounitnoCnosyawlasidaolehT
The load is on without any identifiable
movement
The sensor is not mounted for reliably detecting movement Securely mount enclosure
Movement occurred, but not identified by the sensor
(movement behind wall, movement of small object in
immediate lamp vicinity etc.)
Check zone setting
The load will not work despite movement Rapid movements are being suppressed to minimize
malfunctioning or the detection radius is too small Check zone setting
I – 10%
II – 20%
III – 30%
IV – 50%
This is the dimmed low light output level you would like to have after the hold-time in the absence of people.
Stand-by dimming level
30%
20%
10%
50%
21
I
II
III
IV
SECTION 3 FUNCTIONS
Designed in the software, the sensor switches on/off the load right on the zero-cross point, to ensure the min. current passing through
the relay contact point, and enable the max. load and life-time of the relay.
3.1 Zero-cross relay operation
Double L N terminal makes it easy for wire loop-in and loop-out, saves the cost of terminal block and assembly time.
3.2 Loop-in and loop-out
This 1-10v output is isolated, SELV output.
Motion sensor overwrites daylight sensor, meanning the daylight sensor starts to check the ambient natural light only when the
lamp is switch off (motion hold-time ellapsed).
*
*

Other Hytronik Accessories manuals

Hytronik HC005S/BT Quick guide

Hytronik

Hytronik HC005S/BT Quick guide

Hytronik HIR27 Quick guide

Hytronik

Hytronik HIR27 Quick guide

Hytronik HIM38/RF User manual

Hytronik

Hytronik HIM38/RF User manual

Hytronik HIR32 Quick guide

Hytronik

Hytronik HIR32 Quick guide

Hytronik HMW32 User manual

Hytronik

Hytronik HMW32 User manual

Hytronik Dual Sense HIM11 User manual

Hytronik

Hytronik Dual Sense HIM11 User manual

Hytronik HMW34 Quick guide

Hytronik

Hytronik HMW34 Quick guide

Hytronik HC438V User manual

Hytronik

Hytronik HC438V User manual

Hytronik HC419VRC/R User manual

Hytronik

Hytronik HC419VRC/R User manual

Hytronik HMW34 Quick guide

Hytronik

Hytronik HMW34 Quick guide

Hytronik HMW12 Quick guide

Hytronik

Hytronik HMW12 Quick guide

Hytronik DUAL sense HIM11 Quick guide

Hytronik

Hytronik DUAL sense HIM11 Quick guide

Hytronik HC401SRC/R User manual

Hytronik

Hytronik HC401SRC/R User manual

Hytronik HMW14 Quick guide

Hytronik

Hytronik HMW14 Quick guide

Hytronik HMW30 User manual

Hytronik

Hytronik HMW30 User manual

Hytronik HEC7028 User manual

Hytronik

Hytronik HEC7028 User manual

Hytronik HMW20 Quick guide

Hytronik

Hytronik HMW20 Quick guide

Hytronik HCD038 Quick guide

Hytronik

Hytronik HCD038 Quick guide

Hytronik HC038V User manual

Hytronik

Hytronik HC038V User manual

Hytronik HIM31 Quick guide

Hytronik

Hytronik HIM31 Quick guide

Hytronik HN020-01V User manual

Hytronik

Hytronik HN020-01V User manual

Hytronik HC005S/IR Quick guide

Hytronik

Hytronik HC005S/IR Quick guide

Hytronik HMW39/RF Quick guide

Hytronik

Hytronik HMW39/RF Quick guide

Hytronik HMW32 User manual

Hytronik

Hytronik HMW32 User manual

Popular Accessories manuals by other brands

Riftek RF605-25/50 user manual

Riftek

Riftek RF605-25/50 user manual

Mantracourt BroadWeigh Original instructions

Mantracourt

Mantracourt BroadWeigh Original instructions

Audient iD44 user manual

Audient

Audient iD44 user manual

Philips 22PP3000 brochure

Philips

Philips 22PP3000 brochure

Hornbach 6145082 Installation and user manual

Hornbach

Hornbach 6145082 Installation and user manual

Livescribe Smartpen quick guide

Livescribe

Livescribe Smartpen quick guide

Silvercrest SPB 2.6 A1 User manual and service information

Silvercrest

Silvercrest SPB 2.6 A1 User manual and service information

C.P. Electronics MWS1A-PRM Product guide

C.P. Electronics

C.P. Electronics MWS1A-PRM Product guide

Silvercrest SPB 2.600 B1 operating instructions

Silvercrest

Silvercrest SPB 2.600 B1 operating instructions

MaxiCosi Coral XP manual

MaxiCosi

MaxiCosi Coral XP manual

Endress+Hauser NAR 300 Brief operating instructions

Endress+Hauser

Endress+Hauser NAR 300 Brief operating instructions

Abus FUHA35000C quick start guide

Abus

Abus FUHA35000C quick start guide

UPPAbaby 0254 quick start guide

UPPAbaby

UPPAbaby 0254 quick start guide

Summit Solo Performer manual

Summit

Summit Solo Performer manual

Vava VA-AD007 user guide

Vava

Vava VA-AD007 user guide

QSC DCA Series user manual

QSC

QSC DCA Series user manual

Wetekom 82 99 06 instruction manual

Wetekom

Wetekom 82 99 06 instruction manual

HikRobot SC2000E Mini Series quick start guide

HikRobot

HikRobot SC2000E Mini Series quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.