LED indication
Antenna module
Detection area
Hold-time
Daylight threshold
Stand-by period
Stand-by diming level
Daylight sensor
Push L
N
DALI
This sensor is specially designed for small scale, decentralised retrot project, which contains a DALI power supply circuit and gives
DALI output to the DALI driver to carry out on/off and dimming command. No extra DALI power supply is needed.
45
4.2
28
102
93.2
86.5
2lux / disable
Hold-time
3~10min
6
0
6
Detection Pattern
Functions and Features
Tri-level Control (Corridor Function)
1
Hytronik builds this function inside the motion sensor to achieve tri-level control, for some areas which require a light change notice
before switch-off. The sensor offers 3 levels of light: 100%-->dimmed light -->off; and 2 periods of selectable waiting time: motion
hold-time and stand-by period; Selectable daylight threshold and freedom of detection area.
With sufcient natural light, the
light does not switch on when
presence is detected.
With insufcient natural light,
the sensor switches on the light
automatically when presence is
detected.
After hold-time, the light dims to
stand-by level preset.
Light switches off automatically
after the stand-by period
elapses.
Manual Override
2
* Short Push (<1s): on/off function;
On →Off: the light turns off immediately and cannot be triggered ON by motion until the expiration of pre-set hold-time. After this
period, the sensor goes back to normal sensor mode.
Off →On: the light turns on and goes to sensor mode, no matter if ambient Lux level exceeds the daylight threshold or not.
* Long Push (>1s): adjust the hold-time brightness level between10% and 100%.
Note: if end-user do not want this manual override function, just leave the “push” terminal unconnected to any wire.
This sensor reserves the access of manual override function for end-user to switch on/off, or adjust the brightness by push-switch,
which makes the product more user-friendly and offers more options to t some extra-ordinary demands:
Note:We recommend the mounting distance between sensor to sensor should be more than 2m to prevent sensors from
false-triggering.