Subject to change without notice. Edition: 26 Feb. 2020 Ver. A0 Page 3/6
The light dims to stand-by
period after hold-time and
stays on selected minimum
dimming level.
The light switches off when
the ambient natural light is
sufcient.
The light switches off
completely after the
stand-by period.
Note:
The Light automatically dims down and
eventually turns off if the natural light lux
level exceeds the daylight threshold.
However, if the stand-by period is preset
at “+∞”, the xture never switches off
but dim to minimum level, even the
natural light is sufcient.
Manual Override
2
* Short Push (<1s): on/off function;
On →Off: the light turns off immediately and cannot be triggered ON by motion until the expiration of pre-set hold-time. After this
period, the sensor goes back to normal sensor mode.
Off →On: the light turns on and goes to sensor mode, no matter if ambient Lux level exceeds the daylight threshold or not.
* Long Push (>1s): adjust the target lux level by turning the light up or down. Both the adjustment on remote control and push switch
can overwrite each other. The last adjustment remains in memory.
Note: if end-user do not want this manual override function, just leave the “push” terminal unconnected to any wire.
With the help of push-switch, this sensor can be over-ridden by the end-user to manually switch on/off the light, or adjust the target lux
level by push-switch, which makes the product more user-friendly and offers more options to t some extra-ordinary demands:
Semi-auto Mode (Absence Detection)
3
It is easy to forget to switch off the light, in ofce, corridor, even at home. And in many other cases, people do not want to have a
sensor to switch on the light automatically, for example, when people just quickly pass-by, there is no need to have the light on. The
solution is to apply this “absence detector”: motion sensor is employed, but only activated on the manual press of the push-switch, the
light keeps being ON in the presence, and dims down in the absence, then switches off in the long absence.
Note: end-user can choose either function or function for application. Default function is manual override.
23
zero-cross point
Alternating current
Zero-cross Relay Operation
Designed in the software, sensor switches on/off the
load right at the zero-cross point, to ensure that the
in-rush current is minimised, enabling the maximum
lifetime of the relay.
4
Double L N terminal makes it easy for wire loop-in and loop-out, and saves the cost of terminal block and assembly time.
Loop-in and Loop-out Terminal
5