iLoq D50S.531.SB Installation guide

iLOQ Oy • Oulu, Finland • www.iLOQ.com • iLOQ is registered trademark of iLOQ Oy •
©2022 iLOQ Oy. All Rights Reserved •
D50S.531.SB
EUROPROFILE HALF CYLINDER
FOR SWING HANDLE
MOUNTING AND CARE INSTRUCTIONS
USER GUIDE

iLOQ Oy • Oulu, Finland • www.iLOQ.com • iLOQ is registered trademark of iLOQ Oy •
©2022 iLOQ Oy. All Rights Reserved •
TABLE OF CONTENTS
1 BEFORE INSTALLATION .................................................................. 3
2 AFTER INSTALLATION ..................................................................... 3
3 CARE .................................................................................................. 3
4 INSTALLATION D50S.531 IN SWING HANDLES ............................. 4
5 KNOB CHANGE ................................................................................. 5
6 INSTRUCTIONS FOR USE ................................................................ 6
6.1 OPENING .................................................................................................. 6
6.2 CLOSING .................................................................................................. 7
7 CYLINDER EXTENSION .................................................................... 7
8 GENERAL NOTES ............................................................................. 9
9 DECLARATION OF CONFORMITY ................................................... 9
143173
B

iLOQ Oy • Oulu, Finland • www.iLOQ.com • iLOQ is registered trademark of iLOQ Oy •
©2022 iLOQ Oy. All Rights Reserved •
1 BEFORE INSTALLATION
1. The instructions should be carefully followed during installation. These instructions and
any maintenance instructions should be passed on by the installer to the user.
2. iLOQ D50S cylinders must be installed and used carefully without excessive force.
3. The product should not be modified in any way except in accordance with the modifications
described in these instructions.
4. Care should be taken to ensure that any seals or weather-stripping fitted to the complete
door assembly, does not inhibit the correct operations of D50S cylinder.
5. Care should be taken to ensure that no projection of the D50S cylinder and associated
parts, can prevent the door swinging freely.
6. All components necessary for the specific installation should be fitted in order to
ensure compliance with EN15684 standard.
7. Before fitting D50S cylinder to a fire/smoke resisting door, the fire certification should
be examined, to ensure conformity.
8. The iLOQ cylinders are successfully tested according the EN 1634-1 (EUFI29-19003368) for 120
minutes in a hinged single leaf steel door.
9. The cylinder must project less than 1 mm on outside of the door to ensure proper operation.
10. No liability is accepted for damage to the doors or components due to incorrect installation.
11. D50S.531 cylinder is only available in one length with 30/10 mm, it is only allowed to use max. one
5 mm extension with this cylinder version (AD50.E05).
12. This type of cylinder is developed for the use in swing handles (e.g. for cabinets) which are
prepared for DIN half cylinder. Do not use the cylinder for other purposes resp. use cases.
13. The cylinder has an operating angle of ~ -40° (~from 5 o’clock to 6 o’clock clockwise), do
not try to overturn the cam in any direction.
14. The integrated cam is spring supported, please use with care.
15. We reserve the right to make modifications or further technical developments without further
notice.
16. If there are any deviations from the contents in foreign language versions of the
documentation, the English original shall apply in case of doubt.
2 AFTER INSTALLATION
Test the cylinder functionality after installation to ensure that it does not prevent the lock
application from working properly.
3 CARE
The product is designed to be maintenance-free. It does not require any regular maintenance.

iLOQ Oy • Oulu, Finland • www.iLOQ.com • iLOQ is registered trademark of iLOQ Oy •
©2022 iLOQ Oy. All Rights Reserved •
4 INSTALLATION D50S.531 IN SWING HANDLES
Note: The displayed swing handle below act only as an example to get an idea how to install the
cylinder. Different swing handles are available in the market, but the installation should be similar.
For additional (installation) information please check the documentation from the swing handle
manufacturer.
1 3 4
Note: Perform the functionality test with open door, close the door only after everything is working fine.
1. Hold a valid key against the lock reader knob and wait until the key shows a green light (see
chapter 6).
2. Turn the knob clockwise until the cam is pointing to the 6 o’clock position.
3. Slide the lock cylinder into the swing handle.
4. Fix the cylinder into the swing handle by using the iLOQ fixing screw from the package (A10.155).
Use a tightening torque of 0.9...1.1 Nm.
5 6
5. Make sure that the cylinder is in place and secured, and then move the cylinder with the swing
handle lever back into the housing.
6. Activate the cylinder by using a Smartphone or Key Fob (with access rights) to test if the
combination is working properly.
7. If applicable: Fix the backside housing of the swing handle which is covering the cylinder.
KLICK!
2

iLOQ Oy • Oulu, Finland • www.iLOQ.com • iLOQ is registered trademark of iLOQ Oy •
©2022 iLOQ Oy. All Rights Reserved •
5 KNOB CHANGE
If the reader knob needs a replacement knob, see the following instructions how to replace the reader
knob correctly.
1. Loosen the fixing screw 2. Remove the current knob
3. Attach the new knob 4. Tighten the fixing screw
(1.5 Nm tightening torque)

iLOQ Oy • Oulu, Finland • www.iLOQ.com • iLOQ is registered trademark of iLOQ Oy •
©2022 iLOQ Oy. All Rights Reserved •
6 INSTRUCTIONS FOR USE
6.1 OPENING
1. Hold a valid key against the lock-reader knob and wait until the key shows a green light.
Note: Due to the large variety of Android phone models and operating system
versions, iLOQ cannot guarantee that all NFC-enabled Android phones will work
seamlessly with our locks.
Before using the lock, check the location of the NFC antenna in your phone so that
you know the best position to hold the phone against the lock-reader knob.
2. Turn the lock-reader knob clockwise (~40°) to the six o’clock position and pull and release the
lever of the swing handle out of the housing unlock the door.
3. Pull the lever and open the door.
Turn ~40°

iLOQ Oy • Oulu, Finland • www.iLOQ.com • iLOQ is registered trademark of iLOQ Oy •
©2022 iLOQ Oy. All Rights Reserved •
6.2 CLOSING
For closing/securing a credential with access rights is not necessary.
1 2 3
1. To lock and secure the application close the door and push the lever (incl. the cylinder)
back into the swing handle housing
2. The application is secured when the “click” sound appears.
3. Check if the handle is locked and secured.
7 CYLINDER EXTENSION
The cylinder length is easily adjustable with one 5 mm D50 cylinder extension, to extend
from a basic length of 30 mm up to 35 mm (only the knob side is extendable and only one 5
mm extension peace is allowed).
1 2
1. Remove the three body fixing screws with a Torx T6 tool.
2. Pull the lock unit apart.
KLICK!

iLOQ Oy • Oulu, Finland • www.iLOQ.com • iLOQ is registered trademark of iLOQ Oy •
©2022 iLOQ Oy. All Rights Reserved •
3 4
3. Insert the round extension piece inside the housing extension part opposite
the side with the black sealing, so that the recess is placed next to the black
O-ring.
4. Fix the extension piece with the fixing screw.
5 6
5. Insert the lock unit with the extension piece onto the other part of the cylinder.
6. Fix the lock unit onto the cylinder using 3 fixing screws with a Torx T6 tool. Tighten the
screws. Use a tightening torque of 0.55…0.65 Nm.
Note:

iLOQ Oy • Oulu, Finland • www.iLOQ.com • iLOQ is registered trademark of iLOQ Oy •
©2022 iLOQ Oy. All Rights Reserved •
8 GENERAL NOTES
1. Care should be taken to ensure that any seals or weather-stripping fitted to the
complete door assembly, does not inhibit the correct operations of the cylinder.
2. Care should be taken to ensure that no projection of the cylinder and associated parts,
can prevent the door swinging freely.
3. All components necessary for the specific installation should be fitted.
4. Before fitting D50S cylinder to a fire/smoke resisting door, the fire certification should
be examined, to ensure conformity.
5. The iLOQ cylinders are successfully tested according the EN 1634-1 (EUFI29-
19003368) for 120 minutes in a hinged single leaf steel door.
6. The key is to be kept securely so that only authorized person may have access.
7. In case of losing a key, blocklisting of the lost key shall be done with the iLOQ
Manager software and affected locks shall be reprogrammed.
9 DECLARATION OF CONFORMITY
The products mentioned inside this user guide are in conformity with the requirements of the
following directives:
2014/53/EU Radio Equipment Directive (RED)
2011/65/EU Restriction of the use of certain hazardous substances (RoHS)
The conformity was assessed in accordance with RED module A by using the following harmonized
and other EN standards:
RED:
Art 3.1(a) Safety EN 62368-1:2014 + AC:2015 + AC2:2015
Art 3.1(b) EMC EN EN 301 489-1 v2.2.3
EN 301 489-3 v2.1.1
Art 3.2 Spectrum EN 300 330 v2.1.1
RoHS EN 50581:2012
Table of contents
Other iLoq Lock manuals

iLoq
iLoq D10S Series User manual

iLoq
iLoq G50S.2x1 Installation guide

iLoq
iLoq H50S.31.HC Series Installation guide

iLoq
iLoq S10 User manual

iLoq
iLoq F50S.2x1.HZ User manual

iLoq
iLoq S50 User manual

iLoq
iLoq D5S SB Series User manual

iLoq
iLoq D50S Series Installation guide

iLoq
iLoq S5 User manual

iLoq
iLoq D10 Series Installation guide
Popular Lock manuals by other brands

Alarm Lock
Alarm Lock Wireless Networx PDLN4100 Programming instructions

VIZpin
VIZpin Grade 1 Cylindrical Smartlock installation instructions

DOM
DOM Easykey Slim installation guide

Dorma
Dorma SVP 22 Series installation instructions

Perko
Perko 0927000CHR Mounting instructions

VIZpin
VIZpin Entegrity Smart installation instructions