4.2 General notes
• The iLOQ cylinders are successfully tested according the EN 1634-1 (EUFI29-19003368) for 120
minutes in a hinged single leaf steel door.
• Where the D50S cylinder is manufactured in more than one size, make sure that you select the correct
size.
• Make sure that any seals or weather-stripping fitted to the complete door assembly, does not inhibit
the correct operation of the D50S cylinder.
• Make sure that no projection of the D50S cylinder and associated parts can prevent the door from
swinging freely.
• Fit all components necessary for the specific installation in order to ensure compliance with EN15684
standard.
• The cylinder must protrude less than 1 mm on the outside of the door to ensure proper operation.
• Before fitting the D50S cylinder to a fire/smoke resisting door, examine the fire certification, to ensure
conformity. Consult an iLOQ sales representative for the correct configuration.
• To extend the cylinder length, only use the associated D50 cylinder extensions (AD50.Exx).
• The incorrect type of cylinder can block or hinder the panic mechanism of the panic mortise
locks. Make sure that the anti-panic cylinder (D50S.7xx) is installed. Do not use other cylinder
types (D50S.1xx/2xx/3xxx etc.) unless you have made sure the lock type does not need a specific
cam position and the cam cannot block the panic functionality. Confirm the information from the
declaration of conformity provided by the mortice lock manufacturer.
• After installation, make sure that all parts of the lock are in an operational condition. When the D50S
lock cylinder is used in combination with panic locks, make sure the panic function of the mortise lock
is operational and cannot be hindered.
• To meet the German VdS (VdS Schadenverhütung GmbH) requirements class CZ+ on burglary
threatened doors use D50S.XX0B.SD high security cylinder installed with a VdS approved security lock
furniture of class B or C. Such security lock furniture corresponds to DIN 18 257 class ES 2 and ES 3.
• To meet the Dutch SKG*** requirements use the D50S.XXXA.SD high security cylinder. Consult iLOQ
sales representative for correct configuration.
• The product is designed to be maintenance-free. It doesn’t require any regular maintenance.
However, yearly operational/functional test is recommended.
4.3 Manufacturers involvement
No liability is accepted for damage to the doors or components due to incorrect installation. We reserve
the right to make modifications or further technical developments without further notice.
4