Ink Bird ITC-306T User manual

Plug and Play Temperature Controller
ITC-306T
User Manual
Version 1.1s
Inkbird Tech. Co., Ltd.
Copyright
Copyright©2016 Inkbird Tech. Co., Ltd. All rights reserved. No part of this document may be reproduced
without prior written permission.
Disclaimer
Inkbird has made every effort to ensure that the information contained in this document is accurate and
complete; however, the contents of this document are subject to revision without notice. Please contact
Inkbird to ensure you have the latest version of this document.

ITC-306T User Manual
Inkbird Tech. Co., Ltd. www.ink-bird.com
2
Contents
1. Overview............................................................................................................................................................. 3
What is ITC-306T?........................................................................................................................................3
Main features.................................................................................................................................................. 3
2. Specification.......................................................................................................................................................4
3. Keys Instruction............................................................................................................................................... 5
4. Key Operation Instruction............................................................................................................................ 6
4.1 How to set parameters....................................................................................................................... 6
4.2 Setup Flow Chart...................................................................................................................................7
5. Menu Instruction..............................................................................................................................................8
5.1 Temperature Control Range Setting (TS, DS)...........................................................................9
5.2 Cycle Time Setting (TR, TAH, TAM,TBH, TBM, CTH, CTM)............................................... 10
5.3 Temperature Calibration (CA)....................................................................................................... 10
5.4 Display in Fahrenheit or Centigrade unit (CF)........................................................................ 10
6. Error Description........................................................................................................................................... 10
6.1 Sensor Fault Alarm:...........................................................................................................................10
6.2 Over-temperature Alarm................................................................................................................. 10
6.3 TE error...................................................................................................................................................11
7. Technical Assistance and Warranty....................................................................................................... 11
7.1 Technical Assistance..........................................................................................................................11
7.2 Warranty................................................................................................................................................ 11

ITC-306T User Manual
Inkbird Tech. Co., Ltd. www.ink-bird.com
3
1. Overview
What is ITC-306T?
ITC-306T is a pre-wired heating output temperature controller with time function
specifically for breeding and planting. It can be set to two different temperatures with its
function of dual time cycle setting during 24 hours according to the day and night, which
can more suitable for the physiological needs of animals and plants. ITC-306T can be
widely use in over-heat protection and automatic temperature control system of all sorts of
electrical equipment for aquarium, pets breeding, hatching, fungus fermenting, and seed
germination accelerating, etc.
This plug and play product is designed with dual LCD display, and offers the optional
display of Centigrade or Fahrenheit, which makes it more humanized temperature control.
With large power output 1200W(110V)/2200W(220V), it’s suitable for most applications.
And the temperature can be controlled more accurately with its function of temperature
calibration and temperature hysteresis.
Main features
Plug and play design, easy to use;
Dual time cycle setting during 24hours, can be set different temperature from day and
night on the basis of the physical needs of animals and plants;
Support reading with Centigrade or Fahrenheit unit;
Maximum output load: 1200W(110V) / 2200W(220V);
Dual display window, be able to display measured temperature and set temperature at
the same time;
Temperature calibration;
Over-temperature and sensor fault alarm;
Build-in ultra-capacitor, after fully filled, it can supply timer chip working for more
than 20 days without electricity.

ITC-306T User Manual
Inkbird Tech. Co., Ltd. www.ink-bird.com
4
2. Specification
Temperature Control Range
-50~99 °C / -58~210 ° F
Temperature Resolution
0.1 ° C / 0.1° F
Temperature Accuracy
±1°C (-50 ~ 70°C) / ±1°F (-58 ~ 160° F)
Temperature Control Mode
On/Off Control, Heating
Input Power
100 ~240VAC, 50Hz/60Hz
Temperature Control Output
Max. 10A, 100V ~240V AC
Sensor Type
NTC sensor (Including)
Sensor Length
2m / 6.56ft
Relay Contact Capacity
Heating (10A, 100-240VAC)
Input Power Cable Length
1.5m ( 5ft )
Output Power Cable Length
30cm ( 1ft )
Dimension
Main Body: 140x68x33mm (5.5x2.7x1.3 inch)
Socket (US Version): 85x42x24mm (3.3x1.7x1.0 inch)
Socket (EU Version): 135x54x40mm (5.3x2.1x1.6 inch)
Socket (UK Version): 140x51x27mm (5.5x2.0x1.0 inch)
Ambient Temperature
-30~ 75 ° C / -22~ 167 ° F
Storage
Temperature -20~ 60 ° C / -4~ 140 ° F
Humidity 20~85% (No Condensate )
Warranty
1 Year

ITC-306T User Manual
Inkbird Tech. Co., Ltd. www.ink-bird.com
5
3. Keys Instruction
①PV: Process Value.
Under running mode, display current temperature;
Under setting mode, display menu code.
②SV: Setting Value.
Under running mode, display setting temperature;
Under setting mode, display setting value.
③Work1 Indicator Lamp: When the light is on, start heating.
④Work2 Indicator Lamp: ---
⑤SET key: Press SET key for 3 seconds to enter menu for function setting. During the
setting process, press SET key for 3 seconds to quit and save setting changes.
⑥DECRESE key: Under setting mode, press INCREASE key to increase value.
⑦INCREASE key: under running mode, press INCREASE key to inquiry HD value; under
setting mode, press INCREASE key to increase value.
⑧The Socket: Both sockets are for heating output, and they change synchronously.

ITC-306T User Manual
Inkbird Tech. Co., Ltd. www.ink-bird.com
6
4. Key Operation Instruction
4.1 How to set parameters
When the controller is working normally, press “SET” key for over 3 seconds to enter
parameters set up mode. “SET” indicator lamp will on. PV window displays the first menu
code “TS1”, while SV window displays according setting value. Press “SET” key to go to
next menu and display according menu code, press“” key or “ ” key to set current
parameter value. After setting done, press “SET” key for 3 seconds at any time to save
the parameters change and return to normal temperature display mode. During setting, if
there is no operation for 10 seconds, the system will quit setting mode and return to
normal temperature display mode without saving the parameters change.

ITC-306T User Manual
Inkbird Tech. Co., Ltd. www.ink-bird.com
7
4.2 Setup Flow Chart
Remarks: TE error
If TR=1 and it is power-on again after power off. The window of SV displays TE error.
When enter to the setting menu, it will jump to TH code directly, then you can set present
time (TH, TM) easily and quit into normal working status.

ITC-306T User Manual
Inkbird Tech. Co., Ltd. www.ink-bird.com
8
5. Menu Instruction
When the temperature is displayed in Centigrade
When TR=0 (Default)
Menu code
Function
Setting range
Default setting
Remarks
TS1
Temperature Set Value 1
-50~99.9℃
25℃
5.1
DS1
Heating Differential
Value1
0.3~15℃
1.0℃
CA
Temperature Calibration
-15~15℃
0℃
5.3
CF
Display in Fahrenheit or
Centigrade
C
5.4
TR
Time Setting
0:Off; 1: On
0
5.2
When TR=1 (Time setting function is on)
Menu code
Function
Setting range
Default setting
Remarks
TS1
Temperature Set Value 1
-50~99.9℃
25℃
5.1
DS1
Heating Differential
Value1
0.3~15℃
1.0℃
CA
Temperature Calibration
-15~15℃
0℃
5.3
CF
Display in Fahrenheit or
Centigrade
C
5.4
TR
Time Setting
0:Off; 1: On
1
5.2
TS2
Temperature Set Value 2
0~99.9℃
25℃
5.1
DS2
Heating Differential
Value2
0.3~15℃
1.0℃
TAH
Time A setting Hour
0~24 hours
8(8:00)
5.2
TAM
Time A setting Minute
0~60 minutes
00(8:00)
TBH
Time B setting Hour
0~24 hours
18(18:00)
TBM
Time B setting Minute
0~60 minutes
00(18:00)
CTH
Current Hour Setting
0~24 hours
8
CTM
Current Minute Setting
0~60 minutes
30

ITC-306T User Manual
Inkbird Tech. Co., Ltd. www.ink-bird.com
9
When the temperature is displayed in Fahrenheit
When TR=0(Default)
Menu code
Function
Setting range
Default setting
Remarks
TS1
Temperature Set Value 1
-58~210℉
77℉
5.1
DS1
Heating Differential
Value1
1~30℉
2℉
CA
Temperature Calibration
-15℃~15℉
0℉
5.3
CF
Display in Fahrenheit or
Centigrade
F
5.4
TR
Time Setting
0:Off; 1: On
0
5.2
When TR=1(Time setting function is on)
Menu code
Function
Setting range
Default setting
Remarks
TS1
Temperature Set Value 1
-58~210℉
77℉
5.1
DS1
Heating Differential
Value1
1~30℉
2℉
CA
Temperature Calibration
-15℃~15℉
0℉
5.3
CF
Display in Fahrenheit or
Centigrade
F
5.4
TR
Time Setting
0:Off; 1: On
1
5.2
TS2
Temperature Set Value 1
32~210℉
68℉
5.1
DS2
Heating Differential
Value1
1~30℉
2℉
TAH
Time A setting Hour
0~24 hours
8(8:00)
5.2
TAM
Time A setting Minute
0~60 minutes
00(8:00)
TBH
Time B setting Hour
0~24 hours
18(18:00)
TBM
Time B setting Minute
0~60 minutes
00(18:00)
CTH
Current Hour Setting
0~24 hours
8
CTM
Current Minute Setting
0~60 minutes
30
5.1 Temperature Control Range Setting (TS, DS)
When the controller is working normally, PV window displays current measured
temperature, as well as SV window displays temperature setting value. When the
measured temperature PV≤TS (temperature set value)-DS (heating differential value),
system enter heating status, the WORK1 indicator lamp will on, and heating relay starts to
work; when the measured temperature PV≥ TS (temperature setting), the WORK1
indicator lamp will off, and heating relay will stop working. For example, set TS=25°C,
DS=3°C, when measured temperature is lower or equal to 22°C(TS-DS), system enters
heating status; when the temperature raised to 25°C(TS), stop heating.

ITC-306T User Manual
Inkbird Tech. Co., Ltd. www.ink-bird.com
10
5.2 Cycle Time Setting (TR, TAH, TAM,TBH, TBM, CTH, CTM)
When TR = 0, time setting function is off, and there are not parameter TAH, TAM,TBH,
TBM, CTH, CTM showing in the menu.
When TR=1, time setting function is on.
TA-TB-TA is a cycle, 24 hours.
During time TA-TB, the controller runs as TS1 and DS1 setting; during time TB-TA, the
controller runs as TS2 and DS2 setting;
During 8:00-18:00 (TA-TB), the temperature controls between 23°C~25°C(TS1-
DS1~TS1);
During 18:00 to the next morning 8:00 (TB-TA), the temperature controls between
17°C~18°C(TS2-DS2~TS2);
Parameter TH and Tm are used for current time setting. For example, if now the time is
9:26, then set TH=9, Tm=26.
5.3 Temperature Calibration (CA)
When there is deviation between measured temperature and actual temperature, use
temperature calibration function to align the measured temperature and actual
temperature. The corrected temperature is equal to temperature before calibration plus
corrected value (corrected value could be positive value, 0 or negative value).
5.4 Display in Fahrenheit or Centigrade unit (CF)
Users can select display with Fahrenheit or Centigrade temperature value according to
their own habit. Default setting is display with Centigrade temperature value. For
displaying with Fahrenheit temperature value, set CF value as F.
Attentions: when CF value changed, all the setting value will be recovered to factory
settings.
6. Error Description
6.1 Sensor Fault Alarm: when temperature sensor is in short circuit or open loop,
the controller will initiate sensor fault mode, and cancel all the actions. The buzzer will
alarm, LED displays ER. Buzzer alarm could be dismissed by pressing any key. After faults
solved, the system will return to normal working mode.
6.2 Over-temperature Alarm: when measured temperature exceeds the measuring
range (less than -50°C /-58° F or higher than 99 °C/210 ° F), the controller will initiate
over-temperature alarm mode, and cancel all the actions. The buzzer will alarm, LED
displays HL. Buzzer alarm could be dismissed by pressing any key. When temperature
returns to measuring range, the system will return to normal working status.

ITC-306T User Manual
Inkbird Tech. Co., Ltd. www.ink-bird.com
11
6.3 TE error
When setting TR=1 and if it is power-on again after power off, the “beep - beep” alarm in
0.5Hz frequency of the buzzer. The temperature controlled by the standard of TS1 while
PV window displaying the current temperature and the window of SV displaying TE error.
At this time, Press any keys can stop the alarm. When enter to the setting menu, it will
jump to TH code directly, then you can set present time (TH, TM) easily and quit into
normal working status.
7. Technical Assistance and Warranty
7.1 Technical Assistance
If you have any problems installing or using this thermostat, please carefully and
thoroughly review the instruction manual. If you require assistance, please write us to
[email protected]. We will reply your emails in 24 hours from Monday through Saturday.
You can also visit our web site www.ink-bird.com to find the answers of the common
technical questions.
7.2 Warranty
INKBIRD TECH. C.L. warrants this thermostat for one years from the date of purchase
when operated under normal condition by the original purchaser (not transferable), against
defects caused by INKBIRD’s workmanship or materials. This warranty is limited to the
repair or replacement, at INKBIRD’s discretion, of all or part of the thermostat. The
original receipt is required for warranty purposes.
INKBIRD is not responsible for injury property damage or other consequential damages or
damages of third parties arising directly from an actual or alleged in mater of workmanship
of the product.
There are no representations, warranties, or conditions, express or implied, statutory or
otherwise, other than herein contained in the sale of goods act or any other statue.
Contact Us
Business Hours: 09:00-18:00(GMT+8) from Monday to Friday
URL: www.ink-bird.com
Table of contents
Other Ink Bird Temperature Controllers manuals

Ink Bird
Ink Bird ITC-1000 User manual

Ink Bird
Ink Bird ITC-100 User manual

Ink Bird
Ink Bird ITC-106 User manual

Ink Bird
Ink Bird IHC-230 User manual

Ink Bird
Ink Bird ITC-608T User manual

Ink Bird
Ink Bird ISC-007BW User manual

Ink Bird
Ink Bird ITC-308 User manual

Ink Bird
Ink Bird ITC-308 User manual

Ink Bird
Ink Bird ITC-1000F User manual

Ink Bird
Ink Bird ITC-100 User manual