InterVac CM-120 User manual

RECORD THIS INFORMATION FOR
FUTURE REFERENCES
THE BUILT-IN VACUUM SYSTEM
INSTALLATION AND OPERATING MANUAL
MODEL CM-120
MODEL F-120
MODEL H-120
for surface mounting or converting to flush mounting
for flush mounting inside a wall only
for surface mounting against a wall only
Important: Instructions must stay with unit. Owner read carefully.
WARNING:
This manual must be read and understood before installation, adjustment, service or
maintenance is performed. This unit should be installed by a qualified technician.
Modification of this product can be extremely hazardous and could result in
personal injury or property damage.
InterVac Design Corp., Palm City, FL 34990
Phone 772-463-1400 • Toll Free 1-888-499-1925
MODEL NUMBER _______________________
DATE OF PURCHASE ___________________
PLACE OF PURCHASE__________________
1
Manual # CMFH-e, Rev.9/28/07
Part # W500

IMPORTANT SAFETY INSTRUCTIONS
When using an electrical vacuum cleaner, basic precautions should always be followed including the following:
Read all instructions carefully before using this vacuum cleaner.
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
Do not leave appliance when plugged in. Unplug from an
electrical outlet when not in use and before servicing.
Do not use outdoors or on wet surfaces.
Never operate this vacuum cleaner without a dust bag and filters
in place.
Close attention is necessary when used by or near children.Do
not allow unit to be used as a toy.
Use only for intended use as described in this manual. Use only
the manufacturer's recommended attachments and dust bag.
Do not use with damaged cord or plug. If appliance is not working
as it should, has been dropped, damaged, left outdoors, or fell into
water, return the vacuum cleaner to InterVac or an authorized
service dealer for examination and repair.
Do not put any object into openings. Do not use with any openings
blocked; keep free of dust, lint, hair and any other material that
may reduce air flow. When the secondary filter becomes dirty,
rinse in warm water or replace with a new filter. Filter should be
completely dry before using.
Never drop or insert any object into any opening.
Turn off all controls before unplugging.
Do not pull or carry by cord, do not use cord as a handle, do not
close a door on the cord, or pull cord around sharp edges or
corners. Do not run appliance over cord. Keep cord away from
heated surfaces.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
Do not unplug by pulling on cord. To unplug, grasp the plug, not
the cord.
Keep hair, loose clothing, fingers, and all parts of body away
from any openings and all moving parts.
Do not pick up anything that is burning or smoking, such as
cigarettes, matches, or hot ashes.
Use extra caution when cleaning on stairs.
Do not handle plug or appliance with wet hands.
Do not pick up flammable or combustible liquids such as
gasoline, or use in areas where they may be present.
Do not place objects against the vacuum cleaner. Keep area
clear.
Do not step on the hose or pull the hose forcibly.
Do not pick up large objects such as waste paper or cloth,
which may clog the hose.
Do not install this vacuum cleaner in an area exposed to high
temperatures.
Install this vacuum cleaner in a dry place.
Do not attempt to service the vacuum cleaner. Unit is sealed
and can not be opened without damage to the unit. For service,
call your local authorized service dealer, or InterVac Design's
Customer Care Center.
SAVE THESE INSTRUCTIONS
2
LIMITED WARRANTY
LIMITS AND EXCLUSIONS
InterVac Design Corp. will repair the power unit with new or rebuilt parts, free of charge for six (6) years from the date of original
purchase in the event of a defect in materials or workmanship. No cash refunds. Excluded are the following items that require
normal replacement:
Disposable dust bags, filters, vacuum cleaner tools and vacuum hoses.
This warranty is extended only to the original purchaser. A purchase receipt or other proof of date of original purchase will be
required before warranty performance is rendered.
.
This warranty only covers failures due to defects in materials or workmanship which occurs during normal use and does not
cover damage which occurs in shipment or failures which are caused by products not supplied by InterVac Design, or failures
which result from accident, misuse, abuse, neglect, mishandling, misapplication, alteration, modification, or commercial use
such as hotel, office, restaurant or rental use of the product, or service by anyone other than an authorized service center, or
damage that is attributable to acts of God.
There are no expressed warranties except as listed above.
INTERVAC DESIGN SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM
THE USE OF THIS PRODUCT, OR ARISING OUT OF ANY BREACH OF THIS WARRANTY. ALL EXPRESSED AND
IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE,ARE LIMITED TO THEAPPLICABLE WARRANTY PERIOD SET FORTHABOVE.
Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an
implied warranty last, so the above exclusions or limitations may not apply to you. This warranty gives you specific legal rights
that vary from state to state. If a problem with this product develops during or after the warranty period, you may contact your
dealer or our service center. If the problem is not handled to your satisfaction, than write to the Customer Service Center at the
company address.
You must return your warranty card in order to be covered under these provisions
:
Polarization Instructions for models H120 and CM120 (with cord) only.
These appliances have a polarized plug (one blade is wider than the other). This plug will fit in a
polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not
fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way.

Paper Template: # W601 or # W602
for flush mounting
Paper Template: # W600
for surface mounting
see page 8
Minimum height 6” from floor
3
Tape template to wall
Fig.: A
Fig.: B
MODEL: CM120 (with detachable cord) or H120 surface
mounted with power cord attached
TIP:
External to Wood Surfaces:
External to Drywall (½ thick) Surfaces:
if you do not like to surface mount the vacuum with screws you can use Velcro, ask for our kit # A015
(see Fig.: A)
(see Fig.: A)
Step 1.
Step 2.
Mark the 4 centers accurately.
Step 3.
Step .
TIP:
Step .
Step 1.
Step 2. #W600
Step 3.
Step 4.
Step 5.
Step 6. Very lightly
Step 7. not
Step 8.
Step 9.
TIP:
4
If vacuum cleaner is mounted on its back or side or very low, it may slide off the screw heads when you pull too hard on the
vacuum hose. To prevent this, fasten a small block against the top of the unit.
5
If vacuum cleaner is mounted on its back or side or very low, it may slide off the screws heads when you pull too hard on the
vacuum hose. To prevent this, fasten a small wood block against the top of the unit.
To cover with the vacuum hose as much area as possible, choose a wall or surface that is centrally located
and has an electrical outlet close by.
Cut paper template from instruction manual, page 8. Tape the template to the wall or a surface at a comfortable
operating height or a minimum of 6 inches above the floor.
Carefully remove template from the wall and place it into the operating manual for future references .
Attach the enclosed #8 screws to the wall as marked on the template. Keep the screw heads 1/8” from the wall.
Slide the key holes on the back of the vacuum cleaner over the 4 screw heads and secure by pushing down.
If vacuum cleaner is loose re-tighten screws.
Check to be sure dust bag and motor filter (under dust bag) are in place.
To cover with the vacuum hose as much area as possible, choose a wall or surface that is centrally located
and has an electrical outlet close by.
Tape the paper template on page 8 to a wall at a comfortable operating height or a minimum of 6 inches
above the floor.
With an awl or similar object mark the center of the key holes . Carefull remove template from the
wall and place it into the operating manual for future references .
With a 3/32 drill bit, pre-drill all 4 holes.
Now use a 5/16 drill bit to enlarge the 4 holes to the correct size.
Squeeze the two arms of the anchor together and insert through the hole. hammer the anchor
with the dry-wall surface.
Insert the red key-pin to toggle the anchor open behind the dry-wall, remove red key. Do hammer key.
Attach the four screws (#8) through the anchors into the wall. Keep the screw heads 1/8” from the
wall surface.
Slide the key holes on the back of the vacuum cleaner over the 4 screw heads and push down.
If the vacuum cleaner is loose on the screws re-tighten screw heads a little more.
yaccurately
flush

Specification: 120 Volt, 11 Amp 50/60Hz, Weight 8 lb
:d
Recessed into Wood Surface Installation:
Parts List:
Depending on model
Paper Template # W601 or # B040
Note:
We recommend that vacuum cleaner be mounted against one side of a 2X4 wall stud.
2 dry-wall anchors, 1 red push pin
Paper templates: #W601( #B040), #W600 4 painted screws
3 wire connectors with CM & F units only 2 high filtration bags
Disconnect all electrical power to the wall area before installing!
Do not drill near studs where electrical cable may be secured to studs adjacent to receptacles.
#Y05
CM120 in-wall installation
CM120 (removed cord) and F120 recessed installation only
etaching the power cord from your CM120 vacuum
WARNING: Electrical connections should be made by a qualified electrician
a) Open the 2-3/4 x 1-3/8 side cover ( lower right side of unit) and pull the wires through the opening.
b) Disconnect the wire connectors that are attached to the cord and also pull the green ground wire out. Leave
wires as long as possible.
c) around the electric cord and remove the cord.
d) You are now ready for the in-wall installation.
(see Fig.: B)
(see Fig.: B)
Open the Romex clamp at the bottom side of the unit
GROUNDING INSTRUCTIONS for CM120 and F120 ONLY, WHEN PERMANENTLY WIRED
This appliance must be connected to a grounded metal, permanent wiring system; or an
equipment-grounding conductor must be run with the circuit conductors and connected
to the equipment-grounding terminal or lead on the appliance.
WARNING:
The four mounting holes in the outer corners of the flange of the Vacuum Cleaner must be drilled
from the back of the unit with a 3/16” drill bit when the unit is to be recessed into a wall.
Step 2.
Step 3.
Step 4. - .
Step 5.
Step 6.
Step 7. a
Step 8.
Step 9.
To reach with the vacuum hose as far as possible, choose a wall or surface that is centrally located and has an
electrical outlet or switch from a 16 amp circuit breaker. Make sure the wall is hollow and there are no pipes or
other obstructions in the section you choose.
Locate a space between the mounting stud and the next stud over. Make sure an electrical outlet box, a switch or
wires from a circuit breaker cable are between the studs and easy to reach from the vacuum cleaners access hole.
Tape the template against the wall at a comfortable operating height (or a minimum of 6 inches off the floor) either
at the edge of the 2X4 (use the vertical cut-out line from the template and align with the edge of the 2X4) or
somewhere in between the studs.
Refer to the paper template #W601 or B040 for the cut out
Use only 2 of the 4 anchors when installing against a 2X4. Use all 4 anchors when installing somewhere between
the studs.
Install 14 or 16 gage AWG, 300V minimum Romex cable (use wires rated for at least 95C) from the electrical power
supply and pull the power cable through the wall cut-out.
Same procedure as above, but do not use the drywall anchors. Pre-drill the 4 outer holes 3/32 dia. and secure
vacuum cleaner with the 4 painted screws.
Recessed Installation into ½ inch thick Drywall:
TIP:
Step 1
b
d black to black white to white green bare ground conductor
e
Drywall installation: with a 3” dia. hole saw, cut a hole first and check for obstructions! It is easier to
re-plaster the 3” dry-wall slug than a large cut-out if you do encounter an obstruction.
The vacuum cleaner can be mounted to the side of a 2X4 wall stud or in between 2 studs. No electrical
switches or outlet should be on the installation side when mounted to a 2X4.
After inserting the anchors insert the red key-pin and push hard to toggle the anchor open behind the
dry-wall, remove red key.
) Open the 2 3/4" x 1 3/8" side cover and pull the 3 inside wires through the opening.
) Insert your 120 volt power supply cable through the Romex clamp and out of the side opening.
) With 3 wire nuts connect , and to wires.
) Tighten the Romex clamp and replace the side cover.
Slide the unit, bottom first, into the opening and secure with the four painted screws. If installed against a 2X4
use 2 screws for the 2X4 and 2 screws for the 2 anchors. Do not over-tighten.
Check to be sure dust bag and motor filter (under dust bag) are in place.
4

HOW TO OPERATE YOUR VACUUM CLEANER
InterVac Design Corporation Palm City, Florida, 34990
toll free 1-888-499-1925
e-mail: sales@intervacdesign. com • Website: www.intervacdesign.com
MODELS: F120 + H120 + CM120
NOTE: THE LOWER PART OF THE VACUUM CLEANER WILL BE QUITE WARM WHEN IN USE.
.
IF THE VACUUM STOPS RUNNING:
THE THERMAL PROTECTOR ON THE MOTOR WILL RESET AUTOMATICALLY AFTER ABOUT 1-1/2 HOUR.
Replacement bag # Y05 high filtration or with our Hepa allergy filtration bag # YH1
PLEASE SEE TROUBLE SHOOTING GUIDE.
A. Connecting and disconnecting the hose
B. On / Off Switch
C: How to change the dust bag,
C: To change motor filter, Replacement Part # Y21
1. Lift the inlet valve cover on the front of the door.
2. Insert hose cuff with a to secure.
3. To remove, turn hose in either direction while pulling hose towards you.
1. To start the vacuum cleaner, push the switch to the “I” position.
2. To stop the vacuum cleaner, push the switch to the “O” position.
1. Remove door and dust bag.
2. Reach into the cavity towards the bottom of the vacuum cleaner and remove the motor filter.
3. Replace the filter with a new filter and tuck in the corners so that the filter lays flat on the grid,
with the printed words " facing upward.
4. If necessary, clean the dirty filter by vacuuming or washing in mild soap by hand.
. Let filter dry completely and reuse as needed.
slight twist
1. Open the door on the vacuum cleaner by pushing the latch upward and remove both door and dust bag.
2. Carry door and dust bag to the trash container. Remove full bag and discard.
3. Place a new dust bag all the way over the scoop on the door.
4. When closing door, tuck in the left and right corners of the bag, so the door is properly sealed and the latch
clicks into place.
: If you break off the vacuum hose inlet cover, simply reattach it by lining up one of the small dimples located on
the inside of the inlet cover and than press hard on the other side to click into position.
(see Fig.: E)
TIP
THIS SIDE UP!"
Do not clean in washing machine
5

D: Replacing Exhaust Filter, Part #Y41:
TROUBLE SHOOTING:
NOTE: IF MOTOR SUDDENLY STOPS:
TIP:
CLEANING THE STRETCH HOSE:
Pinch exhaust filter in the middle and pull out.
To replace, pinch in the middle and slide in
one side first. ( washable by hand)
If you use our very convenient stretch hose, but require more suction power, we recommend you try
our standard central vacuum hose.
common cause is a clogged hose. See cleaning instructions.
The bag is overfilled or fine dust has clogged the bag.
The vacuum cleaning tools are clogged.
Vacuuming large amounts of dust other than household dirt, such as dry-wall or fine wood dust can
block the bags pores fast,
The motor filter is dirty and should be cleaned or replaced.
If vacuum unit is installed in a tight compartment and air cannot exhaust, the motor can overheat and
shut off until it cooled down.
The exhaust filter should be checked and washed.
lift the hose up on both ends and dispense some liquid detergent into both ends.
with a garden hose, holding both ends still up, fill ¾ with water.
shake hose up and down, let detergent loosen the dirt.
stretch the hose as far as you can ( 2 people required ) and wash the dirt out with the full pressure of the
garden hose. Repeat if necessary.
Hang hose up , let hose drain and dry , it might take 24 hours.
TIP :
Disconnect vacuum hose from cleaner, hold one end high up in the air and drop a quarter or similar ob-
ject into the hose. If the quarter gets stuck the hose is clogged. Try to unclog the hose with a long stick.
2.
3.
4.
even if the bag is new.
5.
6.
7.
The stretch hose, besides all its’ conveniences, has a tendency to get clogged, especially if you have pets.
a)
b)
c)
d)
e)
1. The most
completely
THIS SIDE UPTHIS SIDE UP
E. Replacing motor filter
Part # Y21
tuck-in the corners and sides
carefully under the ribs
CAUTION:
DO NOT PICK UP LIQUIDS, LIT CIGARETTES, HOT ASHES,
RAZOR BLADES, NEEDLES, PINS OR OTHER SHARP OBJECTS!
6
Fig.: E

8
40’ Stretch Hose As’bly with
Cuff.plain PART# A002
2 Part Upholstery
Tool PART # X300
Dust Brush
PART # X250
Floor/Rug Tool
PART # X403
40’ Stretch Hose As’bly with
Cuff.Banded PART# A002B
Mesh Storage Bag
PART # X501
Complete Tool Kit
(Includes all item on the right)
for Models H, F, CM
for Models RM, RMG
PART # 705
PART # 705B
Telescoping Wand, PART # X154
ACCESSORIES
INTERVAC reserves the right to make improvements and modifications without notice.
DUST BAGS:
PART # Y05-5 (5 pack) high filtration bags for Models H, F, CM
PART # Y06-5 (5 pack) high filtration bags for Models RM, RMG
PART # YH1-3 (3 pack) HEPA allergy bags for Models H, F, CM
NOTE: All Power Units come with 2 Dust Bags
OPTIONAL VACUUM TOOLS
30 Foot Traditional
Central Vacuum Hose
for Models H, F, CM
for Models RM, RMG
PART #A006
PART # A006B
Battery Operated Power
Brush with Charger,
PART # X453
Air Turbo Nozzle
"RUG RAT"
PART # X452
Special Inlet Valve
"VAC-PAN"
PART # 505 Black
Crevice Tool
PART # X200

10
This manual suits for next models
2
Table of contents
Other InterVac Central Vacuum System manuals
Popular Central Vacuum System manuals by other brands

Disan
Disan DS SUPER COMPACT 1,5 Instructions for use

Rehau
Rehau VACUCLEAN 2000 Fitting instructions

TECNOPLUS
TECNOPLUS Sistem-Air revo block professional Technical manual

TECNOPLUS
TECNOPLUS Sistem-Air Industrial Clean Basic Technical manual

NuTone
NuTone CV353 Specifications

Broan
Broan BQ2 Installation and user guide