InfiRay Outdoor •Geni GL35R Series •Quick Start Guide www.infirayouordoor.com
All rights reserved and shall not be copied and distributed in any form without written permission
IMPORTANT SAFETY INFORMATION
Environmental influences
Note: Never point the lens of the device directly at intense heat sources
such as the sun or laser equipment. The objective lens and eyepiece can
function as a burning glass and damage the interior components.
Risk of swallowing
Caution: Do not place this device in the hands of small children. Incorrect
handling can cause small parts to come loose which may be swallowed.
Safety instructions for use
-Do not expose the device to fire or high temperatures.
-The battery capacity decreases when operated in a cold ambient
temperature. This is not a fault and occurs for technical reasons.
-Always store the device in its carrying bag in a dry, well-ventilated
space. For prolonged storage, remove the batteries.
-Do not expose your device to extreme temperatures lower than - 20°C
and higher than + 50°C.
-The product shall only be connected to a USB Type C interface.
-If the device has been damaged or the battery is defective, send the
device to our after-sales service for repair.
User information on the disposal of electrical and electronic devices
(private households)
The WEEE symbol on products and/or
accompanying documents indicates that used
electrical and electronic products must not be mixed
with ordinary household waste. For proper treatment,
recovery and recycling, take these products to the
appropriate collection points where they will be
accepted without charge. In some countries, it may
also be possible to return these products to your local retailer when you
purchase a corresponding new product. The proper disposal of this
product serves to protect the environment and prevents possible harmful
effects on human beings and their surroundings, which may arise as a
result of incorrect handling of waste.
More detailed information on your nearest collection point is available
from your local authority. In accordance with state legislation, penalties
may be imposed for the improper disposal of this type of waste.
For business customers within the European Union
Please contact your dealer or supplier regarding the disposal of electrical
and electronic devices. He will provide you with further information.
Information on disposal in other countries outside of the European
Union
InfiRay Outdoor •Geni GL35R Series •Quick Start Guide www.infirayouordoor.com
All rights reserved and shall not be copied and distributed in any form without written permission
This symbol is only applicable in the European Union. Please contact
your local authority or dealer if you wish to dispose of this product and ask
for a disposal option.
Intended use
The device is intended for displaying heat signatures during nature
observation, remote hunting observations and for civil use. This device is
not a toy for children.
Use the device only as described in this instruction manual. The
manufacturer and the dealer accept no liability for damages which arise
due to non-intended or incorrect use.
Function test
-Before use, please ensure that your device has no visible damage.
-Test to see if the device displays a clear, undisturbed image.
-Check that the settings for the thermal imaging camera are correct. See
the notes in the section Observation mode.
Installing/removing the battery
The Geni thermal imaging scope need to install one 26650 battery for use.
Refer to the section Battery Installation for details.
Observation with and without glasses
Thanks to the flexible eyeshade, the Geni series can be used with or
without glasses. It offers a full field of view in both cases.
InfiRay Outdoor •Geni GL35R Series •Quick Start Guide www.infirayouordoor.com
All rights reserved and shall not be copied and distributed in any form without written permission
1 Specification
Model
Geni GL35R
Microbolometer
Resolution, pixels
384 ×288
Pixel size, μm
12
NETD, mk
≤40
Frame rate, Hz
50
Optical Characteristics
Objective lens, mm
35
Field of view
7.5°×5.7°
Magnification, x
2.81 - 11.24
E-zoom, x
1 / 2 / 3 / 4
Diopter Adjustment, D
-5 ~ +5
Detective range, m
(Target size:1.7m*0.5m, P(n)=99%)
1818
Display
Display type
OLED
Resolution, pixels
1024 ×768
Power Supply
Battery type
26650 ×1
External Power Supply
5V (Type C USB)
Max. Operation time (at t=22℃), h★
7
Operational Characteristics
Max. Recoil Power on Rifled
Weapon, g/s²
1000
Degree of protection, IP code
IP67
Amount of built-in memory, Gb
32
Operating Temperature Range, ℃
-10 ~ +50
Weight (without batteries), g
< 600
Dimension, mm
225 ×100 ×61.5
Rangefinder Characteristics
Wavelength, nm
905
Max. Measuring Range, m/y★★
1000
Measurement Accuracy, m
±1
★The actual operating time depends on the intensity of using Wi-Fi,
video recorder.
★★ The measuring range depends on the characteristics of the object
under observation and environmental conditions.
➢Improvements may be made to the design and software of this product
to enhance its useful features.
➢Technical parameters of the device may be improved without prior
notice of the customer.
InfiRay Outdoor •Geni GL35R Series •Quick Start Guide www.infirayouordoor.com
All rights reserved and shall not be copied and distributed in any form without written permission
2Package Contents
➢GL35R Thermal Imaging Scopes
➢IRM-030-205-Q1 picatinny mount
➢A L-shaped wrench
➢M5 screw ×4 pcs
➢Portable bag
➢Lens cloth
➢Heated target for zeroing ×5pcs
3Description
The Geni series GL35R is an infrared thermal imaging scope with a
built-in laser rangefinder. It can be installed on various types of firearms
for night hunting. It is light in weight, small in size, and easy to carry, and
features a long working time, good concealment, and strong penetration
of thick smoke, dust, or night.
4Components and Controls
1. Eyeshade
2. Eyepiece diopter
adjusting ring
3. Camera (C) button
4. Menu (M) button
5. Zoom (Z) button
6. Power (P) button
7. Battery compartment
8. Type C port
9. Lens focus ring
10.Lens cover
11.Laser rangefinder
12.Objective lens
InfiRay Outdoor •Geni GL35R Series •Quick Start Guide www.infirayouordoor.com
All rights reserved and shall not be copied and distributed in any form without written permission
5Icons Instructions
Image mode: White hot
Motion sensor
Image mode: Black hot
Microphone
Image mode: Red hot
Image hue
Image mode: Color
Zeroing type
Display brightness
More
/ / /
E-zoom
Zeroing
Image sharpness
Defective pixels calibration
Image brightness
Compass calibration
Image contrast
Laser rangefinder calibration
Ultraclear mode
Time setting
Wi-Fi
System information
Auto correction mode
Factory reset
Video out
Return to the Main Menu
PIP
Battery indicator
Digital compass
USB icon
InfiRay Outdoor •Geni GL35R Series •Quick Start Guide www.infirayouordoor.com
All rights reserved and shall not be copied and distributed in any form without written permission
6Description of Controls
Button
Status / Current Operation Mode
Short Press
Long Press
P (Power) Button
Device is off
——
Power on the device
Device is on
Turn the standby mode on/off
Power off the device
Rangefinder Mode
Exit and return to the home screen
——
Menu and function interface
Exit to the upper interface without saving
——
Z (Zoom) Button
Home Screen
Digital Zoom
Enter the rangefinder mode
Main menu / Shortcut menu interface
Navigation upwards
——
Single rangefinder Mode
Distance measurement
Switch rangefinder mode
M (Menu) Button
Home screen
Enter the shortcut menu
Enter the main menu
Shortcut menu
Switch to the next page of the shortcut menu
——
Main menu
Enter the submenu / Confirm selection
Save and exit to the upper interface
Defective pixel calibration
Switch the moving direction
C (Camera) Button
Home screen
Take a Photograph
Start video recording
Main menu / shortcut menu
Navigation downwards
——
Video recording
Take a Photograph
Stop and save video
M + C Buttons
Home screen
Shutter correction
Background correction
Z + M + C Buttons
Home screen
Switch the units between cm/m and inch/yard
——
InfiRay Outdoor •Geni GL35R Series •Quick Start Guide www.infirayouordoor.com
All rights reserved and shall not be copied and distributed in any form without written permission
7Battery Installation
➢Open the battery cover (7) anticlockwise according to the prompt
identification on the device.
➢Place one 26650 battery (13)correctly according to the polarity labels
in the battery compartment.
➢When done, screw tightly the battery cover (7) clockwise.
Attention
-Please use batteries provided by formal manufacturers.
-Geni series can also be connected to an external power supply through
the Type-C data cable. In this case, the USB icon is displayed
on the upper right of the screen.
8Operation
➢Open the lens cover (10).
➢Press and hold down the Z (5) button for 3s to power on the device.
Waite for 6s until thermal image appears on the display.
➢Diopter Adjustment: Adjust the sharp resolution of the icons on the
display by rotating the diopter adjusting ring (2) of the eyepiece.
➢Lens Focus Adjustment: rotate the lens focus ring (9) to focus on the
object being observed.
➢Calibration: in the home screen, calibrate the image with a short press
of the M (4) + C (3) buttons for shutter calibration or long press the M (4)
and C (3) button for background calibration.
InfiRay Outdoor •Geni GL35R Series •Quick Start Guide www.infirayouordoor.com
All rights reserved and shall not be copied and distributed in any form without written permission
➢Image Settings: adjust the image mode, display brightness, digital
zoom, image sharpness, image brightness, image contrast in the
shortcut menu (for more details, see the Shortcut Menu section).
➢Standby Mode: Briefly press the P (6) button to turn the standby mode
on/off. The standby mode can
➢Power off: to power off the device, long press P (6) button for 5s until
the shutdown option menu
appears. Make your selection
to switch “√” or “×”with a
short press of the Z (5) / C (3)
button and confirm your
selection with the M (4)
button. Select the “√” to shut down and “×”to cancel.
➢Reticle On: click the M (4) button four times in a row while pressing
and holding the Z (5) + C (3) button to invoke the reticle function for the
first time use, then long press the Z (5) + M (4) + C (3) button
simultaneously for 7 seconds to turn the reticle on. This function should
be activated when the reticle first enabled.
Attention
➢When the reticle is turned off, all the operations related to it in the menu
will be hidden, including the adjustment of the reticle color and pattern
(in the shortcut menu), the options of zeroing and blind pixel correction
in the main menu.
9Zeroing
Zeroing is recommended to be done at the temperature close to the
scope operating temperature.
Before implementing zeroing setting, please make sure that the reticle is
on and zeroing type is selected in the main menu.
➢Mount the scope on your weapon.
➢Set a target at 100m distance, and power on the scope.
➢For the first use of the scope, please make sure that the reticle is on
before zeroing (refer to the instructions of section 6 Operation).
➢Long press the M (4) button on the home screen to enter the main
menu.
InfiRay Outdoor •Geni GL35R Series •Quick Start Guide www.infirayouordoor.com
All rights reserved and shall not be copied and distributed in any form without written permission
➢Select one zeroing type in the main menu (refer to the Main Menu –
Zeroing Type).
➢Select the Zeroing item in the sunmenu of the MORE item, and press
the M (4) button to enter the Zeroing interface. In the Zeroing interface,
the reticle is shown as a small cross for position adjustment.
➢Then aiming the center of the reticle at the bull’s-eye 100 meters away
and shooting.
➢After firing, observe the actual point of impact.
➢If the bullet hole can be seen on the display of the thermal scope:
⚫While keeping the position
of the device fixed, press
and hold the M (4) and C (3)
button at the same time to
freeze the image, and a
snowflake icon will
appear on the upper-left corner of the screen.
⚫Move the reticle to the position of the actual impact point by the Z
(5) / C (3) button.
⚫Short press the M (4) button to switch the movement direction
between UP-DOWN and RIGHT-LEFT.
⚫After moving the reticle to the bullet hole, press and hold down the
M (4) button to save the position and exit.
➢If the bullet hole cannot be seen on the display of the thermal
scope:
⚫Keep the position of the device fixed, and measure the horizontal
and vertical distance between the bull’s eye and the bullet hole.
⚫According to the measured distance, move the reticle position by
long or short pressing the Z (5) / C (3) button until the distance
marked on the scale plate consistent with the measured distance.
⚫Short press the M (4) button to switch the movement direction
between UP-DOWN and RIGHT-LEFT.
⚫Press and hold down the M (4) button to save and exit when the
process is done.
Notes
-To ensure the accuracy of the position, aiming the bull’s-eye again and
repeat the operations until the bull’s-eye is hit.
-In the zeroing interface, the reticle moves one pixel with a short press of
the Z (5) / C (3) button to the corresponding direction while ten pixels
InfiRay Outdoor •Geni GL35R Series •Quick Start Guide www.infirayouordoor.com
All rights reserved and shall not be copied and distributed in any form without written permission
movement with a long-pressing. One pixel means to move 1.29cm at a
distance of 100 meters or 0.46 inches at a distance of 100 yards.
-Press the Z (5) + M (4) + C (3) buttons briefly at the same time to switch
units (cm/m, inch/yard).
-In the zeroing interface, there is a white dot that represents the original
position of the reticle before calibration implement.
-After zeroing, the center of all reticle will be changed accordingly.
10 Calibration
Calibration enables to equalize the detector temperature and eliminate
the image defects (such as vertical bars, phantom images, etc.). There
are two calibration way –auto or manual.
➢In the main menu, you can turn the Automatic Shutter Calibration
on/off (referring to the Main Menu –Auto Shutter Calibration). When
the automatic calibration is on, the scope will calibrate automatically
according to the software algorithm. There is no need to close the lens
cover (the internal shutter covers the sensor). Before automatic
calibration, there will be a 5 second countdown prompt behind the
shutter icon on the status bar, that can be to cancelled this calibration
during countdown with a short press of the P(6) button.
➢Weather the automatic calibration is turned on or off, user can also
manually calibrate the sensor. In the home screen, short press the M
(4) + C (3) buttons at the
same time to finish the
shutter calibration without
closing the lens cover (the
internal shutter covers the
sensor), meanwhile, press
and hold down the M (4) +
C (3) buttons at the same time to perform the background calibration,
that a prompt of closing the lens cover appears on the display and
background calibration starts after 2s.
11 Digital Zoom
Geni series support to quickly increase the basic magnification by 2 times,
3 times or 4 times, as well as to return to the basic magnification.
InfiRay Outdoor •Geni GL35R Series •Quick Start Guide www.infirayouordoor.com
All rights reserved and shall not be copied and distributed in any form without written permission
➢In the home screen, briefly press the Z (5) button to operate the
incremental digital zoom in loop to switch magnification times. At the
same time, the icon in the top status bar changes accordingly.
➢Also, you can select the digital zoom in the shortcut menu (referring to
the second page of the shortcut menu).
12 Photographing and Video
Recording
Geni series thermal imaging scope is equipped with a function for video
recording and photographing observed images onto the built-in memory
card. The files of images and videos will be named after the time, so it is
recommended to reset the system time in the Main Menu –More - Time
Setting or to synchronize the system time and date in the Settings of the
APP InfiRay Outdoor before using the camera and video function. For
specific operations.
Photographing
➢Take a photo with a short press of the C (3) button in the home screen.
➢A camera icon ( ) shows in the upper-right of the screen and the
image will freeze for 0.5s when the function performs.
Video recording
➢Press and hold the C (3) button in the home screen to start the video
recording.
➢A tooltip showing the recording
time in MM: SS (minutes:
seconds) format will appear in
the upper right corner of the
display.
➢The red dot in the tooltip flashes during recording.
➢During recording, short press the C (3) button to take a photo also.
➢Press and hold the C (3) button again to exit the recording when done.
➢Video and picture files are stored in the built-in memory card after video
recording has been turned off. But the video will not be saved if you skip
the process and shut down the device suddenly instead.
InfiRay Outdoor •Geni GL35R Series •Quick Start Guide www.infirayouordoor.com
All rights reserved and shall not be copied and distributed in any form without written permission
➢The photos and videos can be read on the computer via the USB cable.
Note
-Notice that the recorded video cannot be saved if you directly shut
down or power off the device other than long pressing the C (3) button
to exit
-You can enter and work on the menu during video recording.
-The recording time is accumulated in minutes until the recording stops,
that is, the time shows 60:00 after 59:59.
-The maximum duration of a video recording file is 10 minutes. When it’s
more than 10 minutes, the video will be recorded onto a new file.
-The number of files is limited by the capacity of the device's built-in
memory. Regularly monitor the amount of free memory in the built-in
memory card, transferring footage and photos to other media to free up
space on the memory card.
Memory Access
When the device is turned on and connected to a computer, it is
recognized by the computer as a flash memory card, which is used to
access the device's memory and make copies of pictures and videos.
➢Turn on the device and connect it to the computer through the USB
cable.
➢Double-click "my computer" on the desktop - double-click to open the
device named "Infiray" - then click and open the device
named "Internal Storage" to access
memory.
➢There are different folders named by time in memory.
➢Recorded videos and photographs are saved in these folders in the
format: IMG_HHMMSS_XXX. jpg (for photos) and VID_HHMMSS.mp4
(for video). HHMMSS- hour/minute/ second; XXX - three-digit common
file counter for photos which is NOT reset.
13 Laser Rangefinder Function
➢In the home screen, press and hold the Z (5) button to turn the laser
rangefinder function on/off.
InfiRay Outdoor •Geni GL35R Series •Quick Start Guide www.infirayouordoor.com
All rights reserved and shall not be copied and distributed in any form without written permission
➢The ranging cursor appears on the screen. The rangefinder
information is displayed under the battery level in the upper right
corner of the screen, including the measurement value and ranging
mode.
➢Geni GL35R series has two
ranging modes: SGL (single
ranging) and CONT
(Continuous ranging). Press
and hold down the Z (5) button
to switch between the SGL (the factory default mode) and CONT
mode.
➢In the SGL mode, briefly press Z (5) button to measure the distance of
the target pointed by the cursor.
➢In the CONT mode, the rangefinder information in the upper right
corner will be updated per second in real time automatically according
to the selected object without any keystroke operation.
➢When ranging targets is further than 1000m, the MAX will appear in
the ranging values.
➢Briefly press the P(6) button to exit the laser rangefinder function.
Peculiarities of Laser Rangefinder
➢The accuracy measurement and maximum range depend on the
reflection ratio on the target surface, the angle at which the emitting
beam falls on the target surface and environmental conditions.
Reflectivity is also by surface texture, color, size and shapes of the
object. Usually, a glossy and bright surface presents higher reflectivity
than a darker surface.
➢Accuracy of measurement can also be affected by illumination
condition, fog, smog, rain, snow etc. Ranging performance can
degrade in bright condition or when ranging towards the sun.
➢Measuring range to a small side target is more difficult than a large
size target.
14 Shortcut Menu
The basic settings (image palette, display brightness, digital zoom, image
sharpness, image brightness and contrast, reticle color and pattern) can
be changed using the shortcut menu.
InfiRay Outdoor •Geni GL35R Series •Quick Start Guide www.infirayouordoor.com
All rights reserved and shall not be copied and distributed in any form without written permission
➢In the home screen, short press the M (4) button to enter the shortcut
menu.
➢There are four pages (when the reticle function is invoked) and two
functions on each page, one at the top and one at the bottom.
➢On each page, press the Z (5) button briefly to switch the options of the
top function, and press the C (3) button briefly to switch the options of
the bottom function. And each function has four options
➢Press the M (4) button briefly to switch the next page.
➢Briefly press the P (6) button to exit the shortcut menu.
Shortcut Menu Options and Descriptions
Times of pressing
the M (4) button
Shortcut Menu
Interface
Operation
1 time
Enter the first page of the shortcut menu to
adjust the image palette and screen
brightness
➢Short press the Z (5) button to adjust
image palette among white hot, black
hot, red hot and color.
➢Short press the C (3) button to adjust
the image brightness level from 1 to 4
gradually enhanced.
InfiRay Outdoor •Geni GL35R Series •Quick Start Guide www.infirayouordoor.com
All rights reserved and shall not be copied and distributed in any form without written permission
2 times
Enter the second page of the shortcut menu
to adjust E-zoom and image sharpness
➢Short press the Z (5) button to perform
E-zoom parameter x1, x2, x3 and x4.
➢Short press the C (3) button to adjust
the image brightness level from 1 to 4
gradually enhanced.
3 times
Enter the third page of the shortcut menu to
adjust the image brightness and image
contrast
➢Short press the Z (5) button to
cyclically adjust the image brightness
level from 1 to 4 gradually enhanced.
➢Short press the C (3) button to adjust
the image brightness level from 1 to 4
gradually enhanced.
InfiRay Outdoor •Geni GL35R Series •Quick Start Guide www.infirayouordoor.com
All rights reserved and shall not be copied and distributed in any form without written permission
4 times
Enter the fourth page of the shortcut menu to
adjust reticle color and reticle pattern
➢Short press the Z (5) button to adjust
the reticle color: white, black, red and
green.
➢Short press the C (3) button to select
the reticle pattern. There are 8
patterns for selection.
5 times
Exit to the home screen
——
15 Main Menu
➢In the home screen, press and hold the M (4) button to enter the main
menu, which including Ultraclear mode, Wi-Fi, auto shutter correction,
video output, PIP, compass, motion sensor, microphone, image hue,
zeroing type and more.
➢Press the Z (5) / C (3)button to move through the main menu items.
➢Press the M (4) button briefly to set up the item parameter or to enter the
function interface.
➢Long press the M (4) button to exit the main menu.
Main Menu Options and Descriptions
Ultraclear
Turn Ultraclear mode on/off
➢Press and hold down the M (4) button to enter the Main Menu.
➢Select the Ultraclear menu option with the Z (5) / C (3) button.
➢Turn Ultraclear mode on /off with a short press of M (4) button,
along with the sound of shutter calibration.
➢The icon will be displayed on the status bar in the upper left
corner of the screen when the Ultraclear mode is on.
➢Under heavy fog, rain or snow weather, Ultraclear Mode will show more image details.
Wi-Fi
Turn Wi-Fi function on/off
➢Press and hold down the M (4) button to enter the Main Menu.
➢Select the Wi-Fi menu option with the Z (5) / C (3) button.
➢Turn Wi-Fi function on /off with a short press of M (4) button.
➢The icon will be displayed on the status bar in the upper left corner of the screen when the wi-Fi is on.
InfiRay Outdoor •Geni GL35R Series •Quick Start Guide www.infirayouordoor.com
All rights reserved and shall not be copied and distributed in any form without written permission
Auto shutter
correction
Turn the auto shutter correction on/off
➢Press and hold down the M (4) button to enter the Main Menu.
➢Select the Auto Shutter Correction menu option with the Z (5) / C (3)button.
➢Briefly press of the M (4) button to turn the auto shutter correction on /off.
➢The icon will be displayed on the status bar in the upper left corner of the screen when
the auto shutter correction is on.
➢Before automatic calibration, there will be a 5 second countdown prompt behind the
shutter icon on the status bar, that can be to cancelled this calibration during countdown with a short press of the Power (3) button.
Video Output
Turn video output on/off
➢Press and hold down the M (4) button to enter the Main Menu.
➢Select the Video Output option with the Z (5) / C (3) button.
➢Briefly press of the M (4) button to turn video out on/off.
➢The icon will be displayed on the lower right corner of the screen when the video output function is on.
➢Video out function enable connectivity with an eternal display or recording device.
InfiRay Outdoor •Geni GL35R Series •Quick Start Guide www.infirayouordoor.com
All rights reserved and shall not be copied and distributed in any form without written permission
PIP
Turn Picture-in-Picture on/off
➢Press and hold down the M (4) button to enter the Main Menu.
➢Select the PIP option with the Z (5) / C (3) button.
➢Briefly press of the M (4) button to turn PIP on/off.
➢When the PIP function is on, a small window will appear on the top of the display.
Compass
Turn on/off the digital Compass function
➢Press and hold down the M (4) button to enter the Main Menu.
➢Select the Compass menu option with the Z (5) / C (3) button.
➢Briefly press of the M (4) button to turn the digital compass on/off.
➢When the compass function is turned on, it will reveal in the center of top status bar.
Motion Sensor
Turn on/off the motion sensor
➢Press and hold down the M (4) button to enter the Main Menu.
➢Select the Motion Sensor menu option with the Z (5) / C (3) button.
➢Briefly press of the M (4) button to turn the motion sensor on/off.
➢Two scales are displayed on the right sides of the screen when the motion sensor is on.
➢The horizontal scale shows tilt angle, and the vertical one shows pitch angle.
Microphone
Turn on/off the microphone

This manual suits for next models

1

Other iRay Technology Thermal Camera manuals

iRay Technology G600 User manual

iRay Technology

iRay Technology G600 User manual

iRay Technology Saim SCL Series User manual

iRay Technology

iRay Technology Saim SCL Series User manual

iRay Technology MATE MAL25 User manual

iRay Technology

iRay Technology MATE MAL25 User manual

iRay Technology SCL35W User manual

iRay Technology

iRay Technology SCL35W User manual

iRay Technology InfiRay Jerry-F User manual

iRay Technology

iRay Technology InfiRay Jerry-F User manual

iRay Technology AT31 User manual

iRay Technology

iRay Technology AT31 User manual

iRay Technology AT20 User manual

iRay Technology

iRay Technology AT20 User manual

iRay Technology AT30 User manual

iRay Technology

iRay Technology AT30 User manual

iRay Technology M200 Series User manual

iRay Technology

iRay Technology M200 Series User manual

iRay Technology HT Series User manual

iRay Technology

iRay Technology HT Series User manual

iRay Technology Tianxuan M300G User manual

iRay Technology

iRay Technology Tianxuan M300G User manual

iRay Technology M200 Series User manual

iRay Technology

iRay Technology M200 Series User manual

Popular Thermal Camera manuals by other brands

FLIR K1 quick start

FLIR

FLIR K1 quick start

Bosch GTC 400 C Professional Original instructions

Bosch

Bosch GTC 400 C Professional Original instructions

FLIR VS290-21 quick start

FLIR

FLIR VS290-21 quick start

Perfect Prime IR0280H instruction manual

Perfect Prime

Perfect Prime IR0280H instruction manual

Chauvin Arnoux RayCAm C.A 1886 user manual

Chauvin Arnoux

Chauvin Arnoux RayCAm C.A 1886 user manual

Marconi Instruments P4428 Technical manual

Marconi Instruments

Marconi Instruments P4428 Technical manual

protech QC1950 user manual

protech

protech QC1950 user manual

Intellisystem ThermalTronix TT-1007D MARINE user manual

Intellisystem

Intellisystem ThermalTronix TT-1007D MARINE user manual

FLIR CX series user manual

FLIR

FLIR CX series user manual

Planck VISION SYSTEMS THH960 user manual

Planck VISION SYSTEMS

Planck VISION SYSTEMS THH960 user manual

InfiRay M200 Series user manual

InfiRay

InfiRay M200 Series user manual

Briteq BT-FEVERCAM2 PRO Operation manual

Briteq

Briteq BT-FEVERCAM2 PRO Operation manual

FLIR T4xx series user manual

FLIR

FLIR T4xx series user manual

SYTONG YS Series instruction manual

SYTONG

SYTONG YS Series instruction manual

Fluke Professional Ti300 PRO user manual

Fluke

Fluke Professional Ti300 PRO user manual

HT THT45 user manual

HT

HT THT45 user manual

Snap-On DIAGNOSTIC THERMAL IMAGER quick start guide

Snap-On

Snap-On DIAGNOSTIC THERMAL IMAGER quick start guide

FLIR E series user manual

FLIR

FLIR E series user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.