Page 2
CP-Z-3 E www.ironlogic.me
3. READER OPERATION
The reader operation without the use of the indication's external control:
1. When power is applied and when there is no identifier in the reader field, the LED turns red.
2. When the identifier is close to the reader, its number is read. If this operation is successful,
the LED briefly changes its colour to green and then goes out.
3. While the identifier is still in the reader field, the LED is turned off.
External control of the LEDs red and green colours is carried out by switching the corresponding
control contact onto a common contact (GND).
The external indication can be operated together with the internal indication: by default, internal
control is used for light indication; after the first transmission of an external control signal, the light
indication switches to external control.
To return to internal control, the reader should be powered off and on again.
Table 1 Connecting to the controller
External control for the green LED
External control for the red LED
4. SPECIFICATIONS
Operating frequency, kHz: ..........................................................................................125
Type of identifiers used: ........................ EM-Marin and HID ProxCard® II
Card standard identification:……………………...automatic, without additional settings
Reading range, cm ................................................................................................... 6-10
Output protocol: ...................,...................iButton (Dallas Touch Memory), Wiegand-26
Reader's distance from the controller for the following mode:
iButton (Dallas Touch Memory), m ........................................................................ up to 15
Wiegand-26, m ................................................................................................... up to 100
Card reading confirmation: .................................................................... two-colour LED
Indication: .................................................................. internal and from external control
DC supply voltage, V: .................................................................................................. 12
Current consumption in the card standby mode, mA:................................not more than 35
Case material: ........................................................................................... polycarbonate
Dimensions, mm:.............................................................................................. 78x26x10
5. PACKAGE CONTENTS
Reader CP-Z-3 E ............................. 1 pc.
Self-tapping screw ........................... 2 pcs.
Dowel .............................................. 2 pcs.
Operation Manual ........................... 1 pc.