6.Troubleshooting
Following are a few common problems that may occur during operation. Here
are some suggestions for easy troubleshooting:
A. The unit does not work, no light and the fan does not work
1. Check the connect power and mains fuse.
2. Measure the mains voltage on the mains socket.
B. Not responding to DMX controller
1. DMX LED should be on. If not, check DMX connectors, cables to see if it link
properly.
2. If the DMX LED is on and no response to the channel, check the address
settings and DMX polarity.
3. If you have intermittent DMX signal problems, check the pins on connectors or
on PCB of the unit or the previous one.
4. Try to use another DMX controller.
5. Check in the DMX cables run near or run alongside to high voltage cables that
may cause damage or interference to DMX interface circuit.
C. Some units don’t respond to the easy controller
1. You may have a break in the DMX cabling.
2. Check the LED for the response of the master / slave mode signal.
D. No response to the sound
1. Make sure the unit that does not receive DMX signal.
2. Check microphone to see if it is good by tapping the microphone.
3. Sensitivity is too low, check and set it higher.
E. One of the channels is not working well
1. The stepper motor might be damaged or the cable connected to the PCB is
broken.
2. The motor’s drive IC on the PCB might be out of condition.
F. The lamp is cutting out intermittently
1. The lamp is not working well. Check the mains voltage either too high or too low.
2. Internal temperature may be too high. Check and if necessary replace the fan.
IR-575S
3A
yDon’tconnectthedevicetoanydimmerpackorpowerpack.
yDonottouchanywireduringoperationashighvoltagemightbecausingelectric
shock.
yTopreventorreducetheriskofelectrical shock or fire, do not expose the unit to
rain or moisture.
yNevertouchbulbwithbarefingersasitisveryhotafterusing.
yHotlampexplosionhazard.Donotopentheunitwithinfiveminutesafter
switching off.
yDonotstartontheunitwithoutbulbenclosureorhousingaredamaged.
yThehousing,thelenses,ortheultravioletfilter must be replaced if they are visibly
damaged.
yDonotlookdirectlyatthe light while the bulb is on.
Caution
There are no user serviceable parts inside the unit. Do not open the housing or
attempt any repairs yourself. In the unlikely event your unit may require service,
please contact your nearest dealer.
Installation
The unit should be mounted via its screw holes on the bracket. Always ensure that
the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure
that the structure to which you are attaching the unit is secure and is able to support
10 times weight of the unit.