Operating
Open
(OPEN)
Contact normally open to open. If pressed during the closing operation it stops and
opens (until the end of the limit switch). Acts as “Dead-Man” if kept pressed down with
Option 3 of the options switch triggered.
Close
(CLOSE)
Contact normally open to close. If it is pressed while the door is opening, it stops. Acts as
“Dead-Man” if kept pressed down with Option 2 of the options switch triggered.
Start
(START)
Contact normally open to open and close. The first press opens, the second press
stops (until the limit switch) and the third closes. If pressed during the closing operation
it stops and inverts (until the end of the limit switch). The Start contact only acts as an
open button when using a traffic light card with traffic control enabled.
Temperature
(TEMP)
Contact normally closed for connection to a temperature sensor for the motor. When it
indicates that the motor has exceeded the security limit, the operation will stop until it
has cooled. Where not used, turn option 4 (TEMP) on the input switch to ON.
Stop
(STOP)
Contact normally closed. This detains the operation on standby for a new order. Where
not used, turn option 3 (STOP) on the input switch to ON.
Ends of run
(FC.CL / FC.OP)
Contacts normally closed to mechanically indicate the open and closed end of run.
Where not used, turn option 1 (FC.CL) and 2 (FC.OP) on the input switch to ON.
Security contact
(SEC.CL / SEC.OP)
Contact normally closed, photocell or magnetic detector type. This acts by causing stop-
page and partial inversion during opening and stoppage and total inversion during clos-
ure. Where not used, turn option 5 (SEC.CL) and 6 (SEC.OP) on the input switch to
ON. The security close contact also acts as a close button when the vehicle has passed
if Option 10 on the options switch is enabled.
Security edge
(SEC.EDGE)
Resistive contact for resistive security edge. This acts on closing, causing stoppage and
inversion. Where not used, turn option 7 (SEC.EDGE) on the input switch to ON.
24 Vac output To power any equipment at a voltage of 24 Vac with a maximum consumption of 0,5A
(shared with photocell test output).
Auto-test output
(TEST. SEC)
24 Vac output for auto-test of security parts with a maximum consumption of 0,5A
(shared with 24Vac output).
Auxiliary Contact
(Aux. Contact)
Normally open contact that has three different functions depending on the position of
Option switches 7 and 8.
Auxiliary Contact Function Option switch 7 Option switch 8
Electro-brake: Enables electro-brake to unblock
motor during operations. ON OFF
Anti-intrusion function * ON ON
Electro-lock: Enables electro-lock 3 seconds before
the start of the opening operation. OFF OFF
Garage light: Enables garage light during the door
operating time plus 2 minutes. OFF ON