Cnditi n Parameters
Green LED Red LED Durati n Rate
Valid pushbutton ON OFF 1/10 sec Once
pressed
Timeout expired OFF ON 1 sec; A Once
Valid access ON OFF 1 sec Once
code keyed
Access granted ON OFF 1/10 sec 1 sec
Access granted ON ON 1/10 sec 1 sec
(battery low condition)
Access denied OFF ON 1 sec; A Once; B
Valid programming ON OFF 1 sec Once
entry
Invalid programming OFF ON 1 sec; A Once; B
entry (including
duplicate access code)
Tamper shutdown OFF ON 2 sec Once
beginning
Tamper shutdown state OFF ON 1 sec; C 10 sec
Tamper shutdown ON OFF 2 sec; C Once
ending
Vis al Feedback Message Definitions
S mmary of P shb tton Programming Commands
Name
Diagn stic
C mmand
500 #
123456789*0#
Descripti n f C mmand
‘ anual diagnostic’
www.kabaaccess.c m
Quick
Reference
Guide
PKG3172 0313
For PowerPlex 2000 only:
Lock is ready when front ON OFF 1/10 sec Once
lever is depressed
Lock’s stored power is OFF ON 1/10 sec 1 sec
starting to fade
A= 1/10 second; B = Twice; C = Can be observed only when you pump the lock’s lever
E2000 Operation: Enter your valid PIN to Access the lock and/or to program the
lock at its keypad.
PowerPlex 2000 Operation: This model is a self-po ered lock. To access and/or
program the lock, you must first generate po er by depressing the front lock
lever do n at least once. This energizes the lock temporarily for a fe seconds ,
enough time for you to enter your PIN and open the lock, or start to program the
lock ith a command sequence.
Name
C nfigur
C mmand
000 #
#
#
004 #
TT#
005 #
TT#
006 #
TT#
007 #
TT#
008 #
VV#
009 #
LL#
099 #
Descripti n f C mmand
‘ odify aster User Access Code (lock’s
activation)’ (Always 8 digits)
‘Unlock time setup’ (TT = 02 to 20 seconds)
‘Passage ode Timeout setup’ (TT = 01 to 24
hours - duration time in hours; 00 = no time limit)
N te: N t applicable t P werPlex 2000 m dels
‘Tamper time setup’ (TT = 00 to 90 seconds)
‘Tamper wrong try setup’ (TT = 03 to 09)
‘Buzzer volume control’ (VV = 00 to 03; 00 = off;
01 = Low; 02 = Normal; 03 = High)
‘ odify access length’ (LL = 04 to 08 digits)
‘Reset to factory default values’, except access
code length. ( aster, manager and access user
are retained if already programmed.)
S mmary of P shb tton Programming Commands
To begin, p t lock in programming mode by pressing: #Master Code#
2000 Series
Series