5091_EN iii
Table of contents
1 General informations ....................................................................................................................................................4
1.1 Informations for your safety ...............................................................................................................................................4
1.2 Marking of security instructions.........................................................................................................................................4
1.3 General designated use ......................................................................................................................................................4
1.4 Personnel .............................................................................................................................................................................5
1.5 Modifications, spare parts, accessories ............................................................................................................................5
1.6 General instructions ............................................................................................................................................................5
2 Safety instructions........................................................................................................................................................6
2.1 Intended use ........................................................................................................................................................................6
2.2 General notes.......................................................................................................................................................................6
2.3 General safety instructions.................................................................................................................................................6
3 Delivery, transport and storage .....................................................................................................................................7
3.1 Delivery.................................................................................................................................................................................7
3.2 Transport..............................................................................................................................................................................7
3.3 Storage.................................................................................................................................................................................7
4 Specification.................................................................................................................................................................8
4.1 Valve types...........................................................................................................................................................................8
5 Function and operation .................................................................................................................................................9
5.1 Description of function........................................................................................................................................................9
5.2 Commissioning, service and maintenance........................................................................................................................9
5.2.1 Commissioning...................................................................................................................................................... 9
5.2.2 Service.................................................................................................................................................................. 10
5.2.3 Cleaning ............................................................................................................................................................... 10
6 Technical data ............................................................................................................................................................11
6.1 Check valves Type 5091 ...................................................................................................................................................11
7 Disassembly and assembly .........................................................................................................................................12
7.1 Disassembly.......................................................................................................................................................................12
7.2 Assembly ...........................................................................................................................................................................13
8 Drawings and dimensions ...........................................................................................................................................14
8.1 Drawings ............................................................................................................................................................................14
8.2 Dimensions ........................................................................................................................................................................15
9 Wearing parts .............................................................................................................................................................16
9.1 Wear parts kit.....................................................................................................................................................................16

Operating instruction | Betriebsanleitung1 | General informations
4 / 17 5091_EN
1 General informations
1.1 Informations for your safety
We are pleased that you have decided for a high-class KIESELMANN product. With correct applica-
tion and adequate maintenance, our products provide long time and reliable operation.
Before installation and initiation, please carefully read this instruction manual and the security ad-
vices contained in it. This guarantees reliable and safe operation of this product and your plant re-
spectively. Please note that an incorrect application of the process components may lead to great
material damages and personal injury.
In case of damages caused by non observance of this instruction manual, incorrect initiation, hand-
ling or external interference, guarantee and warranty will lapse!
Our products are produced, mounted and tested with high diligence. However, if there is still a
reason for complaint, we will naturally try to give you entire satisfaction within the scope of our war-
ranty. We will be at your disposal also after expiration of the warranty. In addition, you will also find
all necessary instructions and spare part data for maintenance in this instruction manual. If you
don't want to carry out the maintenance by yourself, our KIESELMANN - service team will naturally
be at your disposal.
1.2 Marking of security instructions
Hints are available in the chapter "safety instructions" or directly before the respective operation in-
struction. The hints are highlighted with a danger symbol and a signal word. Texts beside these
symbols have to be read and adhered to by all means. Please continue with the text and with the
handling at the valve only afterwards.
Symbol Signal word Meaning
DANGER Imminent danger which will result severe personal injury or
death.
WARNING Imminent danger which may result severe personal injury or
death.
CAUTION Dangerous situation which may cause slight personal injury or
material damages.
NOTICE An harmful situation which may result in damages of the product
itself or of adjacent vicinity.
INFORMATION Marks application hints and other information which is particu-
larly useful.
1.3 General designated use
The fitting is designed exclusively for the purposes described below. Using the fitting for purposes
other than those mentioned is considered contrary to its designated use. KIESELMANN cannot be
held liable for any damage resulting from such use. The risk of such misuse lies entirely with the
user. The prerequisite for the reliable and safe operation of the fitting is proper transportation and
storage as well as competent installation and assembly. Operating the fitting within the limits of its
designated use also involves observing the operating, inspection and maintenance instructions.

KIESELMANN GmbH | Operating instruction General informations | 1
5091_EN 5 / 17
1.4 Personnel
Personnel entrusted with the operation and maintenance of the tank safety system must have the
suitable qualification to carry out their tasks. They must be informed about possible dangers and
must understand and observe the safety instructions given in the relevant manual. Only allow quali-
fied personnel to make electrical connections.
1.5 Modifications, spare parts, accessories
Unauthorized modifications, additions or conversions which affect the safety of the fitting are not
permitted. Safety devices must not be bypassed, removed or made inactive. Only use original spare
parts and accessories recommended by the manufacturer.
1.6 General instructions
The user is obliged to operate the fitting only when it is in good working order. In addition to the in-
structions given in the operating manual, please observe the relevant accident prevention regula-
tions, generally accepted safety regulations, regulations effective in the country of installation,
working and safety instructions effective in the user's plant.

Operating instruction | Betriebsanleitung2 | Safety instructions
6 / 17 5091_EN
2 Safety instructions
2.1 Intended use
This type of non-return valve is used as an independent non-return stop valve for liquid and gas me-
dia in systems used in the food and drinks industry, the pharmaceutical industry and the biotechno-
logy industry.
2.2 General notes
NOTICE - observe the operating instructions
To avoid danger and damage, the fitting must be used in accordance with the safety instructions
and technical data contained in the operating instructions.
NOTICE
All data are in line with the current state of development. Subject to change as a result of tech-
nical progress.
2.3 General safety instructions
WARNING
Risk of injury by outflowing medium
Dismantling the valve or valve assemblies from the plant can cause injuries.
a) Medias flowing through the leakage drain outlet are to be drained off without splashing into a
discharge arrangement.
b) Carry the disassembling only if when the plant has been rendered pressure-less and free of li-
quid and gas.
WARNING
ATEX - Guidelines
If the valve or the plant is operated in a potentially explosive atmosphere, the valid ATEX directive of
the EC and the installation instructions in this operating manual must be observed.
CAUTION
Before starting the system, the entire pipeline system must be thoroughly cleaned.
CAUTION
Steps should be taken to ensure that no external forces are exerted on the fitting.

KIESELMANN GmbH | Operating instruction Delivery, transport and storage | 3
5091_EN 7 / 17
3 Delivery, transport and storage
3.1 Delivery
Immediately after receipt check the delivery for completeness and transport damages.
Remove the packaging from the product.
Retain packaging material, or expose of according to local regulations.
3.2 Transport
CAUTION
Risk of injury and damage to the product
During the transport the generally acknowledged rules of technology, the national accident preven-
tion regulationsand company internal work and safety regulations must be observed.
3.3 Storage
NOTICE
Damage to the product due to improper storage!
Observe storage instructions
avoid a prolonged storage
INFORMATION
Recommendation for longer storage
We recommend regularly checking the product and the prevailing storage conditions during long
storage times.
• To avoid damage to seals and bearings,
– products up to DN 125 / OD 5 inch should be stored horizontally for maximum 6 months.
– products larger than DN 125 / 5 inch, should be stored in the upright position with the actu-
ator on top.
• Don't store any objects on the products.
• Protect the products for wetness, dust and dirt.
• The product should be stored in a dry and well ventilated room at a constant temperature (op-
timal indoor temperature: 25C ±5; indoor humidity data 70% ±5%).
• Protect seals, bearings and plastic parts for UV light and ozone.

Operating instruction | Betriebsanleitung4 | Specification
8 / 17 5091_EN
4 Specification
4.1 Valve types
check valve O-ring - design
Couplings with connections
• S-K/M = welded end- taper nut
• G-K/M = male - taper nut
• K/M-K/M = taper nut - taper nut
• Cl-K/M = clamp- taper nut
Valve housings with connections
• G-S = male - welded coupling
• G-G = male - male
• G-K/M = male - taper nut
• G-Cl = male - clamp
Valve size seals
DN Inch EPDM HNBR FKM Silicone
010 = DN 10 - x x - -
015 = DN 15 - x x - x
020 = DN 20 - x x - -
025 = DN 25 026 = OD 1" x x x -
032 = DN 32 - x x x -
040 = DN 40 038 = OD 1 1/2" x x x x
050 = DN 50 051 = OD 2 " x x x x
065 = DN 65 064 = OD 2 1/2" x x x -
080 = DN 80 076 = OD 3 " x x x -
100 = DN 100 101 = OD 4 " x x x -
DN = nominal diameter = z.B. 5091 050 000-041
OD = outside diameter= z.B. 5091 051 000-041

KIESELMANN GmbH | Operating instruction Function and operation | 5
5091_EN 9 / 17
5 Function and operation
5.1 Description of function
The valve open against spring power with flow pressure > X bar in flow direction “A“ (see Tab.). The
valve close added by spring power with flow pressure > 0,1 bar in flow direction “B“.
B
A
Nominal diameter DN / OD
DIN
Inch
10
-
15
-
20
-
25
1
32
-
40
1½
50
2
65
2½
80
3
100
4
Flow pressure:10.50 0.40 0.20 0.11 0.09 0.14 0.15 0.16 0.15 0.07
1. measured in installation position and flow direction from bottom to top
NOTICE
A pressure from minimum 0,8 bar is necessary for a leakproof shut off in flow direction "B".
5.2 Commissioning, service and maintenance
5.2.1 Commissioning
5.2.1.1 Installation instructions
Fitting position
Unidirectional disc valves are preferably fitted vertically, with a flow from bottom to top.
Other installations are possible, but the fitting’s function must be thoroughly checked in operation.
NOTICE
The flow should generally run along the direction of arrow A.
With horizontal installation, a small amount of fluid remains in the sphere in the casing.
5.2.1.2 General welding guidelines
Sealing elements integrated in weld components must generally be removed prior to welding. To
prevent damage, welding should be undertaken by certified personnel (EN ISO 9606-1). Use the TIG
(Tungsten Inert Gas) welding process.
CAUTION
Damage and injuries due to high temperature supply
To avoid a distortion of the components, all welding parts must be welded to stress-relieved.
Allow all components to cool before assembling.
NOTICE
Damage due to impurities
Impurities can cause damage to the seals and seals area.
Clean inside areas prior to assembly.

Operating instruction | Betriebsanleitung5 | Function and operation
10 / 17 5091_EN
5.2.1.3 ATEX - Guidelines
For valves or plants/installations that are operated in the ATEX area, sufficient bonding (grounding)
must be ensured (see valid ATEX Guidelines EG).
5.2.2 Service
Maintenance interval
The maintenance intervals depend on the operating conditions "temperature, temperature-intervals,
medium, cleaning medium, pressure and opening frequency". We recommend replacing the seals 1-
year cycle The user, however should establish appropriate maintenance intervals according to the
condition of the seals.
RECOMMENDATION
Replacement of seals
To achieve optimal maintenance cycles, the following points must be observed!
a) When replacement of seals, all product-contacting seals should be replaced.
b) Only original spare parts may be installed.
Lubricant recommendation
EPDM; HNBR; NBR; FKM; k-flex - Klüber Paraliq GTE703*
Silicone - Klüber Sintheso pro AA2*
Thread - Interflon Food*
*) It is only permitted to use approved lubricants, if the respective fitting is used for the production
of food or drink. Please observe the relevant safety data sheets of the manufacturers of lubric-
ants.
Lubricant recommendation
EPDM; HNBR; NBR; FKM; k-flex - Klüber Paraliq GTE703*
Silicone - Klüber Sintheso pro AA2*
Thread - Interflon Food*
*) It is only permitted to use approved lubricants, if the respective fitting is used for the production
of food or drink. Please observe the relevant safety data sheets of the manufacturers of lubric-
ants.
5.2.3 Cleaning
Cleaning
Ideally, cleaning is carried out with duct cleaning when the valve is open.

KIESELMANN GmbH | Operating instruction Technical data | 6
5091_EN 11 / 17
6 Technical data
6.1 Check valves Type 5091
Model: check valve
Design: Sealing = O-ring
Valve size: DIN: DN10 - DN100
Inch: OD1 - OD4
Connections: Welded end (S) DIN EN 10357
Male (G) DIN 11851
Liner/nut (K/M) DIN 11851
Clamp (Cl)
Temperature range:: Ambient temperature:
Operating temperature:
Sterilization temperature:
+4 to +45°C (air)
+0 to +95°C (medium dependent)
EPDM +140°C (SIP 30 min)
HNBR +110°C (SIP 30 min)
FKM +95°C (SIP 30 min)
Silicone +110°C (SIP 30 min)
Operating pressures: 10 bar
Leak rate: A (DIN EN 12266-1)
Materials:
(in product contact)
Stainless steel: 1.4301 / AISI304
1.4404 / AISI316L
Surfaces: Ra < 0,8µm e-polished
Sealing material: EPDM (FDA)
HNBR (FDA)
FKM (FDA)
Silicone (FDA)
DN / OD
DIN
Inch
10
-
15
-
20
-
25
1
32
-
40
1½
50
2
65
2½
80
3
100
4
KV-value (m³/h): 1 3.5 4.5 18 28.5 36 60 104 150 230

Operating instruction | Betriebsanleitung7 | Disassembly and assembly
12 / 17 5091_EN
7 Disassembly and assembly
7.1 Disassembly
T11 Hinged hook wrench - 8027000065-000
T30 Needle - -
NOTICE
All screw connections have right-handed threads.
Disassembly
• Unscrew the nuts (N) on both sides and remove the valve from the pipe system.
• Dismount the inner parts from housing (VG).
• Remove O-ring (D1).
NOTICE
a) Puncture the O-ring with a needle and remove them carefully from the groove of piston.
• Remove O-ring (D2) and (D3).
T30
1
D1
1 Plate S1 Socket S-K/M
2 Spring S2 Socket G - K/M
3 guidance S3 Socket K/M - K/M
4 Adapter (DN10-DN20) S4 Socket Cl - K/M
D1 O-ring VG1 Housing G-S
D2 O-ring VG2 Housing G-G
D3 Seal (DN10-DN20) VG3 Housing G-K/M
N Slotted nut VG4 Housing G-Cl
S = welded end; G = male; K/M = cone/nut; Cl = clamp

KIESELMANN GmbH | Operating instruction Disassembly and assembly | 7
5091_EN 13 / 17
7.2 Assembly
INFORMATION
a) For the installation and removal is axially a minimum space requirement necessary (measure
X).
b) Alternately press and roll the O-ring (D1) into the groove with round body.
• Before installation, thoroughly clean and slightly lubricate mounting areas and running sur-
faces.
• Assemble in reverse order.
NOTICE
Alternately press and roll the O-ring into the groove with round body.
Performance test
• Check the function according to the specified performance data in the operating state.

Operating instruction | Betriebsanleitung8 | Drawings and dimensions
14 / 17 5091_EN
8 Drawings and dimensions
8.1 Drawings
DN10 - DN20
• 1 = Plate
• 2 = Spring
• 3 = Guidance
• 4 = Receiver
• D1 = O-ring
• D2 = -
• D3 = Seal
• VG2 = Housing
DN25 - DN100
• 1 = Plate
• 2 = Spring
• 3 = Guidance
• D1 = O-ring
• D2 = O-ring
• VG2 = Housing

KIESELMANN GmbH | Operating instruction Drawings and dimensions | 8
5091_EN 15 / 17
8.2 Dimensions
DN D1 D2 D3 D4 G1 L1 L2 L3 L4 X1 X2 X3 X4 a
10 10 13 10 34 Rd28x1/8 17 38 34 42 41 45 58 59 4
15 16 19 16 34 Rd34x1/8 17 38 34 42 49 50 66 70 4
20 20 23 20 34 Rd44x1/6 18 42 36 43 52 58 70 69.5 6
25 26 29 25.5 50.5 Rd52x1/6 22 51 44 43.5 48 50 70 69.5 7
32 32 35 30 50.5 Rd58x1/6 25 57 50 46.5 50 51 75 71.5 7
40 38 41 36 50.5 Rd65x1/6 26 59 52 47.5 58 59 84 79.5 7
50 50 53 47 64 Rd78x1/6 28 63 56 49.5 66 66 94 87.5 8
65 66 70 64 91 Rd95x1/6 40 80 72 68 73 75 105 104 12
80 81 85 77 106 Rd110x1/4 45 90 82 72 87 88 124 115 15
100 100 104 100 119 Rd130x1/4 50 104 94 78 107 117 151 135 9
OD D1 D2 D3 D4 G1 L1 L2 L3 L4 X1 X2 X3 X4 a
1“ 22.
1
25.4 22.1 50.5 Rd52x1/6 20 - - - 49 52 - 70.5 7
1½“ 34.
8
38.1 34.8 50.5 Rd65x1/6 26 - - 47.5 58 59 - 79.5 7
2“ 47.
5
50.8 47.5 64 Rd78x1/6 28 - - 49.5 66 66 - 87.5 8
2½“ 60.
2
63.5 60.2 77.5 Rd95x1/6 40 - - 68 - 78 - 101 12
3“ 72.
1
76.1 72.1 91 Rd110x1/4 45 - - - - 92 - - 15
4“ 97.
6
101.
6
97.6 119 Rd130x1/4 50 - - - - 117 - - 9

Operating instruction | Betriebsanleitung9 | Wearing parts
16 / 17 5091_EN
9 Wearing parts
9.1 Wear parts kit
Wear parts set EPDM O-Ring-design
DN Set- EPDM Pos. D1 Pos. D2 / D3 Pos. 2
DIN / Inch include positions
D1, D2 respectivly.
2, D3
O-ring
(plate)
D3 Dichtring (DN10-DN20)
D2 O-Ring (DN25-DN100)
Spring
10 / - 5099 010 000-060 2304 009 025-170 2004 010 000-054 8150 115
030-031
15 / - 5099 015 000-060 2304 012 030-170 2004 015 000-054 8150 117
070-031
20 / - 5099 020 000-060 2304 014 030-170 2004 020 000-054 8150 117
070-031
25 / 1 5099 025 029-054 2304 020 030-170 2304 035 030-170 8150 117
060-031
32 / - 5099 032 029-054 2304 024 035-170 2304 042 030-170 8150 117
060-031
40 / 1½ 5099 040 029-054 2304 028 035-170 2304 046 030-170 8150 181
000-031
50 / 2 5099 050 029-054 2304 041 035-170 2304 060 030-170 8150 182
000-031
65 / 2½ 5099 065 029-054 2304 057 035-170 2304 085 035-159 8150 209
000-031
80 / 3 5099 080 029-054 2304 069 035-170 2304 100 040-159 8150 236
000-031
100 / 4 5099 100 029-054 2304 088 035-170 2304 117 035-159 8150 236
000-031
Wear parts set HNBR O-ring - design
DN Set- HNBR Pos. D1 Pos. D2 / D3 Pos. 2
DIN / Inch include positions
D1, D2 respectivly.
2, D3
O-ring
(plate)
D3 Dichtring (DN10-DN20)
D2 O-Ring (DN25-DN100)
Spring
10 / - 5099 010 000-050 2304 009 025-055 2004 010 000-050 8150 115
030-031
15 / - 5099 015 000-050 2304 012 030-055 2004 015 000-050 8150 117
070-031
20 / - 5099 020 000-050 2304 014 030-050 2004 020 000-050 8150 117
070-031
25 / 1 5099 025 029-050 2304 020 030-050 2304 035 030-050 8150 117
060-031
32 / - 5099 032 029-050 2304 024 035-050 2304 041 035-050 8150 117
060-031
40 / 1½ 5099 040 029-050 2304 028 035-050 2304 047 025-157 8150 181
000-031
50 / 2 5099 050 029-050 2304 041 035-050 2304 060 030-050 8150 182
000-031
65 / 2½ 5099 065 029-050 2304 057 035-050 2304 085 035-050 8150 209
000-031
80 / 3 5099 080 029-050 2304 069 035-050 2304 100 040-050 8150 236
000-031

KIESELMANN GmbH | Operating instruction Wearing parts | 9
5091_EN 17 / 17
DN Set- HNBR Pos. D1 Pos. D2 / D3 Pos. 2
DIN / Inch include positions
D1, D2 respectivly.
2, D3
O-ring
(plate)
D3 Dichtring (DN10-DN20)
D2 O-Ring (DN25-DN100)
Spring
100 / 4 5099 100 029-050 2304 088 035-050 2304 118 054-050 8150 236
000-031
Wear parts set VITON O-ring - design
DN Set- VITON Pos. D1 Pos. D2 Pos. 2
DIN / Inch include positions
D1, D2, 2
O-ring
(plate)
O-ring Spring
10 / - 5099 010 000-051 2304 009 025-051 2008 010 000-051 8150 115
030-031
15 / - 5099 015 000-051 2304 012 030-051 2008 015 000-051 8150 117
070-031
20 / - 5099 020 000-051 2304 014 030-051 2004 020 000-051 8150 117
070-031
25 / 1 5099 025 029-051 2304 020 030-051 2304 035 030-051 8150 117
060-031
32 / - 5099 032 029-051 2304 024 035-051 2304 041 035-051 8150 117
060-031
40 / 1½ 5099 040 029-051 2304 028 035-051 2304 047 035-178 8150 181
000-031
50 / 2 5099 050 029-051 2304 041 035-051 2304 062 030-051 8150 182
000-031
65 / 2½ 5099 065 029-051 2304 057 035-051 2304 085 035-051 8150 209
000-031
80 / 3 5099 080 029-051 2304 069 035-051 2304 100 040-051 8150 236
000-031
100 / 4 5099 100 029-051 2304 088 035-051 2304 118 045-051 8150 236
000-031
Wear parts set SILICONE O-ring - design
DN Set - SILICONE Pos. D1 Pos. D2 Pos. 2
DIN / Inch include positions
D1, D2, 2
O-ring
(plate)
O-ring Spring
10 / - - - - -
15 / - - 2304 012 030-052 2007 015 000-052 8150 117
070-031
20 / - - - - -
25 / 1 - - - -
32 / - - - - -
40 / 1½ - - - -
50 / 2 - 2304 041 035-052 2304 060 035-052 8150 182
000-031
65 / 2½ - 2304 054 035-052 2304 085 035-052 8150 209
000-031
80 / 3 - - - -
100 / 4 - - - -
Table of contents
Other KIESELMANN Control Unit manuals

KIESELMANN
KIESELMANN 406 Series User manual

KIESELMANN
KIESELMANN 402 Series User manual

KIESELMANN
KIESELMANN 582x User manual

KIESELMANN
KIESELMANN 6268 User manual

KIESELMANN
KIESELMANN 6155 User manual

KIESELMANN
KIESELMANN 91 Series User manual

KIESELMANN
KIESELMANN 5098 User manual

KIESELMANN
KIESELMANN 6164 User manual

KIESELMANN
KIESELMANN 6125 User manual

KIESELMANN
KIESELMANN 5714 User manual