TROUBLESHOOTING GUIDE
PROBLEM POSSIBLE CAUSE SOLUTION
No start at
all or stops
immediately
after start
Motor is burnt Repair or replace
Voltage drop Raise the voltage to the rating
Failure during
operation The protector is actuated
Remove foreign substance if
the impeller is clogged
Lower the liquid temperature
if it is too high
No pumping
or poor
performance
Voltage drop Raise the voltage to the rating
High delivery head Lower the head
Discharge pipe is clogged Overhauling
Impeller wear Replacement
1. Leak Current Breaker
For home use, attach a leak current breaker, GFCI (offered separately) to ensure safety.
2. Connect the power source
Absolutely refrain from connecting this pump to any other power source than 110V AC, 60Hz.
3. Water to use
*Absolutely refrain from using the pump for any oil, sea water, strong alkaline or strong
acidic solution, or any agricultural chemicals.
4. Do not run dry!
Idling can cause trouble, to prevent short cycling place pump at deepest position as possible.
5. Handling of power cord (cabtype cable)
a. Never lift or move pump by power cord. Only lift by handle or tie rope supplied to handle.
b. Select and use proper size extension cord. Do not run extension cord in water.
6. Using in bath, etc.
Do not enter the water when pump is being used.
Check the power circuit
The GFCI, leakage circuit
breaker is actuated
Correct the connection
Not properly connected to
power circuit
Repair the point of leakage
The impeller is caught
by foreign substance
Clogging of foreign matter
in strainer pump Overhauling
WIRING DIAGRAM
DEMENSION
Condenser
Black
Red
White
White
Green
Black
Blue
Power
Cord
Handle
E
308
222.5
151.5
3161
208
279
6000
Unit: mm
180
88
243
SPECIFICATIONS PERFORMANCE CURVE
Note: Performance ratings are guaranteed minimum,
not inflated maximum.
(L/min)
DELIVERY VOLUME (USG/min)
TOTAL HEAD (ft)
40
30
20
10
20 40 60 80
0
100 300200 (m)
12
10
8
6
4
2
PX-65011
INSTALLATION AND USE
Model
Connection Dia
Total Head
Delivery Volume
Voltage
Frequency
Rated Current
Consumption of Electric Power
Out put
Revolution
Power Cord
Net weight
Standard Accessories
PX-65011
2" (50mm)
32.8ft (10m)
68.65GPM (260L/min)
Single 110V
60Hz
6.5A
700W
400W
3400rpm
19.7ft (6m)
24 Lbs. (11kg)
16.4ft (5m) Rope
PUMPMOTOR
*Motive current sends about three times as much
as rated current.
• An acceptable motor-control switch shall be provided at the time of installation.
• CSA enclosure 3
• Thermally protected
AFTER USING PUMP
1. In cold climates, do not allow pump to freeze.
Remove pump from water to prevent damage due to freezing.
2. Completely drain and dry pump of water before storing.
CAUTION