KYLAND Technology SICOM3028GPT Series Assembly instructions

SICOM3028GPT/3424PT/3028GP/3424P
Series Industrial Ethernet Switch
Hardware Installation Manual
Kyland Technology Co., LTD.
Publication Date: Mar. 2012
Version: V1.2
Customer Service Hotline: (+8610) 88796676
FAX: (+8610) 88796678
Website: http://www.kyland.cn
E-mail: support@kyland.biz

SICOM3028GPT/3424PT/3028GP/3424P User’s Manual-v1.2
1
SICOM3028GPT/3424PT/3028GP/3424P Series Industrial Ethernet Switch
Hardware Installation Manual
Disclaimer: Kyland Technology Co., Ltd. tries to keep the content of this manual as
accurate and as updated as possible. T his document i s not g uaranteed t o b e
error-free, and we reserve the right to amend it without notice to users.
Copyright © 2012 KYLAND Technology CO., LTD.
All rights reserved.
No part of this documentation may be excerpted, reproduced, translated, annotated or
duplicated, i n any form or by any m eans without t he pr ior w ritten permission o f
KYLAND Corporation.

SICOM3028GPT/3424PT/3028GP/3424P User’s Manual-v1.2
2
Notice for Safety Operation
This pr oduct per forms r eliably as long as it is used acc ording t o t he g uidance.
Artificial damage or destruction of the equipment should be avoided.
Read this manual carefully and keep it for future reference;
Do not place the equipment near water sources or damp areas;
Do not place anything on power cable or put the cable in unreachable places;
Do not tie or wrap the cable, which may cause a fire risk;
Power co nnectors and ot her eq uipment co nnectors should be f irmly
interconnected and checked frequently;
Do not repair the equipment by yourself, unless it is clearly specified in the
manual;
Please keep the equipment clean; if necessary, wipe the equipment with soft
cotton cloth.
In the following cases, please immediately shut down your power supply and
contact your Kyland representative:
Water gets into the equipment;
Equipment damage or shell damage;
Equipment operation or performance has abnormally changed;
The equipment emits odor, smoke or abnormal noise.

SICOM3028GPT/3424PT/3028GP/3424P User’s Manual-v1.2
3
Contents
1 Packing List ......................................................................................................... 5
2 Product Overview ............................................................................................... 5
3 Structure and Interface ....................................................................................... 6
3.1 Front Panel .................................................................................................. 6
3.2 Rear Panel .................................................................................................. 6
3.2.1 Rear Panel 1U Slot ............................................................................ 7
3.2.2 Rear Panel 0.5U Slot ......................................................................... 8
4 Interface Modules Mounting .............................................................................. 9
4.1 Interface Modules Mounting ...................................................................... 10
4.2 Interface Modules Removal ....................................................................... 12
5 Switch Chassis Mounting ................................................................................ 16
5.1 Dimension Drawing ................................................................................... 16
5.2 Mounting Steps ......................................................................................... 17
6 Cable Connection ............................................................................................. 19
6.1 10/100Base-T(X) Ethernet Port ................................................................. 19
6.2 100Base-FX Ethernet Port ........................................................................ 21
6.3 10/100/1000Base-T(X) Ethernet Port ........................................................ 22
6.4 1000Base-X, 10/100/1000Base-T(X) SFP Port ......................................... 23
6.4.1 Gigabit SFP Optical Module ............................................................. 23
6.4.2 Gigabit SFP Electrical Module ......................................................... 25
6.5 Console Interface ...................................................................................... 26
6.6 Power ........................................................................................................ 27
6.7 Grounding .................................................................................................. 28
6.8 Relay Contact ............................................................................................ 29

SICOM3028GPT/3424PT/3028GP/3424P User’s Manual-v1.2
4
7 LED Indicators .................................................................................................. 29
8 Power-on Self-inspection ................................................................................. 31
9 Management Access ...................................................................................... 32
9.1 Connected through Console Port .............................................................. 32
9.2 Connected through Ethernet Cable ........................................................... 34
9.3 Web Access ............................................................................................... 35
10 Product Configuration Information ................................................................. 36
11 Basic Features and Specifications .................................................................. 38

SICOM3028GPT/3424PT/3028GP/3424P User’s Manual-v1.2
5
1 Packing List
Industrial Ethernet Switch 1
CD (including Hardware Installation Manual, Web Operation Manual and
Windows utility) 1
Screwdriver 1
Mounting Bracket 2
Puller 1
Certificate of Quality (including Certificate of Compliance) 1
Note: After unpacking, please check the accessories and the appearance of the equipment. If
anything is missing or damaged, please contact us.
2 Product Overview
The s eries switches include SICOM3028GPT/3424PT/3028GP/3424P layer 2
switch as shown i n Table 1.They al l ad opt f lexible modular desi gn f or easy
expansion.
Table 1 Product Model
Model
Interface Description
PTP
SICOM3028GPT
Supports max 28 Gigabit ports
Supported
SICOM3424PT
Supports max 4 G igabit por ts and 24 f ast
Ethernet ports Supported
SICOM3028GP
Supports max 28 Gigabit ports
Unsupported
SICOM3424P
Supports max 4 G igabit por ts and 24 f ast
Ethernet ports Unsupported
The series switches support 19 inch 1U Rack mounting by their front/rear panel.
They provide one 1U slot and six 0.5U slots in the rear panel, applied extensively
in power, rail transit, coal mining and many other industries. They are compliant
with IEC61850-3 an d I EEE1613; provide Mini U SB C onsole p ort; su pport
IEC62439-6; support VCT (Virtual Cable Test).

SICOM3028GPT/3424PT/3028GP/3424P User’s Manual-v1.2
6
3 Structure and Interface
3.1 Front Panel
Figure 1 Front Panel
1: Alarm-Alarm LED
2: Run-Running LED
3: Ring-Ring LED
4: Lock-Synchronization Finish LED
5: PWR2-Power 2 LED
6: PWR1-Power 1 LED
7: Slot (1-7) Speed (1-4)-4 port Speed LEDs (Slot (1-7))
8: Slot (1-7) Link/ACT (1-4)-4 port Link/ACTLEDs ((Slot (1-7))
9: Console-Console interface (Mini USB)
10: USB interface (for future release)
11: Front mounting bracket
3.2 Rear Panel
Figure 2 Rear Panel
1: 1U Slot1 for 4-port Gigabit interface module
2: 0.5U Slot2 for 4-port Ethernet interface module
3: 0.5U Slot3 for 4-port Ethernet interface module
4: 0.5U Slot4 for 4-port Ethernet interface module

SICOM3028GPT/3424PT/3028GP/3424P User’s Manual-v1.2
7
5: 0.5U Slot5 for 4-port Ethernet interface module
6: 0.5U Slot6 for 4-port Ethernet interface module
7: 0.5U Slot7 for 4-port Ethernet interface module
8: Alarm contact
9: Grounding screw
10: Terminal block for power input
11: Rear mounting bracket
3.2.1 Rear Panel 1U Slot
SM6.6-4GX-1U
SM6.6-4GX-1U:
4 1000Base-X, 10/100/1000Base-T(X) SFP ports
Figure 3 SM6.6-4GX-1U
SM6.6-2GX-2GE-1U
SM6.6-2GX-2GE-1U:
2 1000Base-X, 10/100/1000Base-T(X) SFP ports
2 10/100/1000Base-T(X) RJ45 ports
Figure 4 SM6.6-2GX-2GE-1U
SM6.6-4GE-1U
SM6.6-4GE-1U:
4 10/100/1000Base-T(X) RJ45 ports
Figure 5 SM6.6-4GE-1U

SICOM3028GPT/3424PT/3028GP/3424P User’s Manual-v1.2
8
3.2.2 Rear Panel 0.5U Slot
SM6.6-4GX-0.5U
Figure 6 SM6.6-4GX-0.5U
SM6.6-4GX-0.5U: 4 1000Base-X, 10/100/1000Base-T(X) SFP ports
SM6.6-2GX-2S/M-0.5U
Figure 7 SM6.6-2GX-2S/M-0.5U
SM6.6-2GX-2S/M-0.5U:
2 1000Base-X, 10/100/1000Base-T(X) SFP ports
2 100Base-FX, SM/MM ports, FC/SC/ST connector
SM6.6-4GE-0.5U
Figure 8 SM6.6-4GE-0.5U
SM6.6-4GE-0.5U: 4 10/100/1000Base-T(X) RJ45 ports
SM6.6-2GX-2GE-0.5U
Figure 9 SM6.6-2GX-2GE-0.5U
SM6.6-2GX-2GE-0.5U:

SICOM3028GPT/3424PT/3028GP/3424P User’s Manual-v1.2
9
2 1000Base-X, 10/100/1000Base-T(X) SFP ports
2 10/100/1000Base-T(X) RJ45 ports
SM6.6-4S/M-0.5U
Figure 10 SM6.6-4S/M-0.5U
SM6.6-4S/M-0.5U:
4 100Base-FX, SM/MM ports, FC/SC/ST connector
SM6.6-2S/M-2T-0.5U
Figure 11 SM6.6-2S/M-2T-0.5U
SM6.6-2S/M -2T-0.5U:
2 100Base-FX, SM/MM ports, FC/SC/ST connector
2 10/100Base-T(X) RJ45 ports
SM6.6-4T-0.5U
Figure 12 SM6.6-4T-0.5U
SM6.6-4T-0.5U: 4 10/100Base-T(X) RJ45 ports
4 Interface Modules Mounting
Note: We recommend that the interface modules be installed and removed while the power is
disconnected.

SICOM3028GPT/3424PT/3028GP/3424P User’s Manual-v1.2
10
4.1 Interface Modules Mounting
The series switches provide one 1U Slot (Slot1) and six 0.5U Slots (Slot2-Slot7) in
the rear panel as shown in Figure 2. Interface modules can be installed into slots
as needed. The models of the interface modules are shown in Table 11.
Note: Not all the slots need to be installed with the interface modules; you can choose the
appropriate slots according to specific requirements.
0.5U interface modules installation in upper slots(Slot2,Slot4 and Slot6)
Step 1: C hoose the a ppropriate 0.5U interface m odule. Insert the interface
module with the port numbers (1, 2, 3, 4) facing up. I nsert the guide rail of
interface module into the guide rail slot, as shown in Figure 13 , and t hen
push the interface module into the slot completely along the guide rail slot.
Figure 13 0.5U Interface Module Mounting 1
Step 2: Secure the interface module into the switch chassis with two screws
(M2.5×5), as shown in Figure 14.

SICOM3028GPT/3424PT/3028GP/3424P User’s Manual-v1.2
11
Figure 14 0.5U Interface Module Mounting 2
0.5U interface modules installation in lower slots(Slot3,Slot5 and Slot7)
Step 1: C hoose the a ppropriate 0 .5U i nterface module. Insert the i nterface
module with the port numbers (1, 2, 3, 4) upside down. Insert the guide rail of
interface module into the guide rail slot, as shown in Figure 15, and then push
the interface module into the slot completely along the guide rail slot.
Figure 15 0.5U Interface Module Mounting 3
Step 2: Secure the interface module into the switch chassis with two screws

SICOM3028GPT/3424PT/3028GP/3424P User’s Manual-v1.2
12
(M2.5×5), as shown in Figure 16 .
Figure 16 0.5U Interface Module Mounting 4
1U interface modules mounting in Slot1
The installation instructions for 1U interface modules in Slot1 are the same as
in upper slots (Slot2, Slot4 and Slot6). Please refer to the instructions above.
4.2 Interface Modules Removal
0.5U interface modules removal
When removing the 0.5U interface modules, a puller as shown in Figure 17 is
needed.
Figure 17 Puller
The specific mounting steps are as follows: (removal for upper and lower slots
is the same)

SICOM3028GPT/3424PT/3028GP/3424P User’s Manual-v1.2
13
Step 1: Remove the two fastening screws of the interface module and switch
chassis.
Step 2: Insert the long tab into the handle of the interface module, as shown in
Figure 18; then move the puller left to ensure adequate space for inserting the
short tab.
Figure 18 Interface Modules Removal 1
Step 3: Insert the short tab of the puller into the other handle of the interface
module as shown in Figure 19; move the puller to the right to keep both of the
tabs inserted into the two handles of the interface module, as shown in Figure
20.

SICOM3028GPT/3424PT/3028GP/3424P User’s Manual-v1.2
14
Figure 19 Interface Modules Removal 2
Figure 20 Interface Modules Removal 3
Step 4: Grip the handle of puller; push the handle in the direction of arrow 1
with y our t humb, an d at t he sa me t ime pull the handle out wards with your
fingers in the direction of arrow 2. The interface module will pop-up. Pull the
interface module outwards along the guide rail slot, until it completely comes
out of the switch chassis.

SICOM3028GPT/3424PT/3028GP/3424P User’s Manual-v1.2
15
Figure 21 Interface Modules Removal 4
Note: When using the puller, ensure to insert the long tab into the handle of the interface module
first and then insert the short tab; otherwise the long and s hort tabs will not be inserted into the
handles because of the specific design of the puller.
1U interface modules removal
Step 1: Remove the three fastening screws o f the i nterface m odules and
switch chassis.
Step 2: Pull the handle of the interface module outwards along the guide rail
slot, until it completely comes out of the switch chassis, as shown in Figure
22.

SICOM3028GPT/3424PT/3028GP/3424P User’s Manual-v1.2
16
Figure 22 Interface Modules Removal 5
5 Switch Chassis Mounting
5.1 Dimension Drawing

SICOM3028GPT/3424PT/3028GP/3424P User’s Manual-v1.2
17
Figure 23 Mounting Dimension Drawing
Note: The switch housing is part of the heat dissipation system, which becomes hot during
operation. Please use caution when coming in contact and avoid covering the ventilation
holes of the switch housing when the switch is operating.
5.2 Mounting Steps
The series switches support rack mounting by its front/rear panel.
The steps of mounting by the front panel

SICOM3028GPT/3424PT/3028GP/3424P User’s Manual-v1.2
18
Step 1: Select the mounting position for the switch in the rack and ensure that
there is adequate space for it.
Step 2: As shown in Figure 24, move the switch in the direction of arrow 1 and
align the holes in the switch mounting brackets and the corresponding holes
in the rack; use 4 screws (M5×14) to fix the switch in the rack.
Figure 24 Mounting by Front Panel
Removal steps
Step 1: U nscrew 4 sc rews fastening t he switch and t he r ack as shown i n
Figure 25.
Step 2: Remove the switch from the rack along the direction of arrow 1.
Figure 25 Removal
The steps of mounting by the rear panel
Step 1: Select the mounting position for the switch in the rack and ensure that

SICOM3028GPT/3424PT/3028GP/3424P User’s Manual-v1.2
19
there is adequate space for it.
Step 2: As shown in Figure 26, move the switch in the direction of arrow 1 and
align the holes in the mounting brackets and the corresponding holes in the
rack; use 4 screws (M5×14) to fix the switch in the rack.
Figure 26 Mounting by Rear Panel
Removal steps
Step 1: U nscrew 4 sc rews fastening t he switch and t he r ack as shown i n
Figure 27.
Step 2: Remove the switch from the rack along the direction of arrow 1.
Figure 27 Removal
6 Cable Connection
6.1 10/100Base-T(X) Ethernet Port
10/100Base-T(X) Ethernet RJ45 port can be connected to terminal equipment and
network devices with st raight-through c ables or cr ossover ca bles. R J45
connectors must be equipped at both ends of cable.
Other manuals for SICOM3028GPT Series
1
This manual suits for next models
3
Table of contents
Other KYLAND Technology Switch manuals

KYLAND Technology
KYLAND Technology KIEN5000 User manual

KYLAND Technology
KYLAND Technology SICOM3024P User manual

KYLAND Technology
KYLAND Technology SICOM1005R-M12 User manual

KYLAND Technology
KYLAND Technology KIEN1005A Assembly instructions

KYLAND Technology
KYLAND Technology Aquam8512 User manual

KYLAND Technology
KYLAND Technology SICOM6000A Assembly instructions

KYLAND Technology
KYLAND Technology SICOM Series Instruction sheet

KYLAND Technology
KYLAND Technology SICOM3016 Series Assembly instructions

KYLAND Technology
KYLAND Technology SICOM3009A Series User manual

KYLAND Technology
KYLAND Technology KIEN2032 User manual