Cautions and warnings
- There are electronic components mounted inside the manikin’s
airway management head. The following techniques should not
be performed on this manikin due to the inability to properly
sanitize the airway if they are performed:
1. Mouth-to-mouth/Mouth-to-mask ventilation
2. Insertion of simulated vomit for suctioning
- Lubricate the oral and nasal airways liberally with the lubricant
provided prior to inserting any instrument or tube into the airway.
Additionally, instruments and tubes should also be lubricated prior
to use.
- Do not allow the manikin's skin to come in direct contact with ink
or photocopied paper, as this can permanently stain the skin.
Avoid using colored plastic gloves when handling the manikin, as
they may also cause discoloration.
- Care should be taken when palpating the pulses to not use exces-
sive force as this will result in no pulse being felt.
- If a training session involves the administration of fluids and/or
drugs into the IV arm, empty the arm immediately following the
training session.
Defibrillation
- Only apply the defibrillator to a defibrillation chest skin which is
properly mounted on the manikin's chest.
- Do not provide more than 2 x 360J defibrillator discharges per
minute as an average over a period of time to prevent overheat-
ing.
- The manikin chest must be kept dry. Special attention should be
taken when using IV Arm.
- Do not apply conductive gel or conductive defibrillation pads
intended for patient use to prevent chest skin pitting.
- Do not use cables or connectors with visible damage.
- Observe all normal safety precautions for use of defibrillators.
- Defibrillation must be performed over the two defibrillation con-
nectors only.
Standards/Approvals
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including
interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to art 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or
more of the following measures:
- Reorient or relocate the receiving antenna.
- Consult the dealer or an experienced radio/TV technician
for help.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
Caution: Changes or modifications not expressly approved by
Laerdal could void the user's authority to operate this equipment.
Hereby, Laerdal Medical declares that when carrying the CE-mark,
the Resusci Anne Advanced SkillTrainer product with VitalSim
remote control is in compliance with the essential requirements
and other relevant provisions of Directive 1999/5/EC.