manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. LEGRAND
  6. •
  7. Cables And Connectors
  8. •
  9. LEGRAND Green up 0 904 72 User manual

LEGRAND Green up 0 904 72 User manual

Catalogue number(s): 0 904 72 - 0 904 78
Technical data sheet: F01850EN/03 Updated: 22/06/2021 Created: 30/09/2013
1/3
2 P+E socket outlets - German standard
IP 55 - IK 08
128, av. du Maréchal-de-Lattre-de-Tassigny - 87045 LIMOGES Cedex
Tel: +33(0)5 55 06 87 87 - Fax: +33(0)5 55 06 88 88
www.legrand.com
100
70
VEHICLE MANUFACTURER DETAILS
MODE 2MODE 1
Occasional charging possible on
conventional socket
Legrand Green’up Access
secure socket for day-to-day
charging of electric vehicles
Charging time cut
by at least 30% with
the Green’Up Access
socket**
*To be carried out by a professional
electrician.
**Charging time varies according to vehicle
model.
INSTALLER DETAILS
Dedicated line
with 30 mA,
type F (HPi), 16 A
single phase RCBO
The earth
measurement
must be checked*
100% electric vehicles
Rechargeable hybrid vehicles
Extended-range electric vehicles
Scooters, quad bikes and light vehicles up
to 8 A
2.5 mm2
0 904 72 0 904 78
1. USE
3.7 kW, modes 1 and 2, 2 P+E, 16 A, 230 V, German standard socket
outlet with safety shutters.
- For safe charging of electric vehicles supplied in modes 1 and 2
(charging on a domestic socket).
- Cost-eective, safe 2 P+E socket certied for all electric vehicles (mode
1 and mode 2). Equipped with optimised connection terminals, metal
contacts with silver surface treatment (5 µm). Equipped with Green’up
System, a Legrand technology.
- Patented Green’up System: the EV detects the secure Green’up Access
infrastructure and selects the maximum power that can be supplied via
the socket (reduced charging time).
- Suitable for private houses and workplaces.
- It is connected from the electrical panel via a dedicated line (1 line per
socket) with protection via a 30mA - 16 A type F (HPi) RCBO.
Bus cable Cat. No. 0 492 31 can be used as an option to migrate to the
Green’Up Premium communication terminal (full mode 3 ready).
2. RANGE
Description Cat. No.
2 P+E socket outlet - surface mounted
Equipped with an ISO 20 cable gland on the socket outlet and an
ISO 20 plug which is not tted.
Supplied with bracket Cat. No. 0 904 78.
0 904 72
Bracket with hooks
For suspending the charging cable control box. 0 904 78
2/3
Catalogue number(s): 0 904 72 - 0 904 78
Technical data sheet: F01850EN/03 Updated: 22/06/2021 Created: 30/09/2013
2 P+E socket outlets - German standard
IP 55 - IK 08
3. POSITIONING (continued)
3.3 Installation recommendation
MODE 2
4. OVERALL DIMENSIONS (mm)
76,5
76,5
Ø 5 mm
A
C
D
B
0 904 72
Cat. Nos A B C D E F
0 904 72 98 98 117 70 - -
0 904 78 180 147.5 115 92.5 6 28
E
B
F
B
D
C
A
0 904 78
3. POSITIONING
3.1 Fixing
The box is xed onto the support frame using 2 (or 4) Ø 4 to 4.5 mm screws
IP 55 weatherproof xing for all surfaces.
ISO 20 - 1000 R02V cable
Rigid or identical exible type
3.2 Assembly
The front part (mechanism cover) is attached to the box using 4 coarse
pitch screws.
(Min. tightening torque for IP 55: 0.5 Nm).
3.3 Installation recommendation
MODE 1




100 - 120 cm
100 - 120 cm
3/3
Catalogue number(s): 0 904 72 - 0 904 78
Technical data sheet: F01850EN/03 Updated: 22/06/2021 Created: 30/09/2013
2 P+E socket outlets - German standard
IP 55 - IK 08
6. TECHNICAL FEATURES
6.1 Mechanical features
Impact test: IK 08
Penetration by solid/liquid matter: IP 55
6.2 Materials
- Box and cover: glass bre reinforced polypropylene, colour light grey
T029
- Mechanism: polycarbonate, colour grey RAL 7016
- Cover xing screws: stainless steel
- Seal: SEBS elastomer, colour green (anise)
UV resistance:
No noticeable change in appearance following 7-day test with ≈
550 W/m2lighting.
(Colorimetric measurement according to laboratory).
Withstands products which are: - Chlorinated, pH 10-11
- Alkaline, pH 9-10
- Acid, pH 3
Salt spray resistance: 7 days (168 h)
Halogen-free
Self-extinguishing:
850°C/30 s for insulating components holding live parts in place.
650°C for other insulating components
.
6.3 Climate features
Storage and usage temperatures: - 20°C to + 40°C
6.4 Electrical features
Voltage: 230 V~
Power: 3.7 kW
Current: 16 A
Frequency: 50/60 Hz
Charging all electric vehicles equipped with a mode 1 or mode 2 cable,
and with batteries up to 25 kW/h capacity.
7. MAINTENANCE
Withstands high-pressure cleaning at 70 to 90 bar, at 70 to 80°C.
Surface cleaning with a dry cloth or cloth moistened with soapy water.
Do not use acetone, tar-removing cleaning agents or trichloroethylene.
8. ACCESSORIES
8.3 Bracket Cat. No. 0 904 78
Bracket with hooks
For suspending the charging cable control box.
8.4 ISO 20 cable gland Cat. No. 0 980 03
Spare part.
9. STANDARDS AND APPROVALS
Conforms to standards IEC 60884-1 and DIN 49440-1.
Conforms to the LCIE test programme for qualication of EV reinforced
sockets: 125 8-hour charge-discharge cycles at 16 A at 230 V~.
5. CONNECTION
Pillar terminals supplied open, with screws locked in unscrewed position
Min. capacity: 1 x 1.5 mm2
Max. capacity: 1 x 6 mm2rigid or equivalent
Min. tightening torque: 0.8 Nm
Screwdriver: Flat, 3.5 to 5 mm
Phillips No. 1
Installation wiring diagram
N
L
-25
Hpi
C16
4 107 53
A single socket per dedicated line
Wire cross-section
3 x 2.5 mm2rigid or
equivalent
50 m max.
1000 R02V cable
Rigid or identical
exible type
Min. tightening = 0.8 N.m
C16 30 mA, 16 A
Type F (HPi) RCBO
Cat. No. 4 107 53
Please note:
Your installer will advise you on the most suitable electricity supply
taris for charging your vehicle.
Always unplug the socket before starting the vehicle.
Only the cables supplied with the vehicle are authorised for use with
the EV sockets.
Use of extension cables or adapters is prohibited.
The EVSE box must be suspended.
Use of a voltage surge protector is recommended.

This manual suits for next models

1

Other LEGRAND Cables And Connectors manuals

LEGRAND LE-50444 User manual

LEGRAND

LEGRAND LE-50444 User manual

LEGRAND SPX 00 User manual

LEGRAND

LEGRAND SPX 00 User manual

LEGRAND Wiremold OFR Series User manual

LEGRAND

LEGRAND Wiremold OFR Series User manual

LEGRAND 4 130 39 User manual

LEGRAND

LEGRAND 4 130 39 User manual

LEGRAND Wiremold 2000TRGFI User manual

LEGRAND

LEGRAND Wiremold 2000TRGFI User manual

LEGRAND AV3STC User manual

LEGRAND

LEGRAND AV3STC User manual

LEGRAND 882 02 User manual

LEGRAND

LEGRAND 882 02 User manual

LEGRAND WIREMOLD MDSA User manual

LEGRAND

LEGRAND WIREMOLD MDSA User manual

LEGRAND 0 648 47 User manual

LEGRAND

LEGRAND 0 648 47 User manual

LEGRAND 4 132 05 User manual

LEGRAND

LEGRAND 4 132 05 User manual

LEGRAND 330 48 User manual

LEGRAND

LEGRAND 330 48 User manual

LEGRAND LCS 0 337 53 User manual

LEGRAND

LEGRAND LCS 0 337 53 User manual

LEGRAND Galion 2 824 54 User manual

LEGRAND

LEGRAND Galion 2 824 54 User manual

LEGRAND ON-Q HT2102-WH-C1 User manual

LEGRAND

LEGRAND ON-Q HT2102-WH-C1 User manual

LEGRAND Pass & Seymour 1597PC User manual

LEGRAND

LEGRAND Pass & Seymour 1597PC User manual

LEGRAND ON-Q HT2302B User manual

LEGRAND

LEGRAND ON-Q HT2302B User manual

LEGRAND RC7FF Poke-Thru Series User manual

LEGRAND

LEGRAND RC7FF Poke-Thru Series User manual

LEGRAND Cablofil User manual

LEGRAND

LEGRAND Cablofil User manual

LEGRAND Keystone RJ 45 Instruction Manual

LEGRAND

LEGRAND Keystone RJ 45 Instruction Manual

LEGRAND WIREMOLD XEVCABLE User manual

LEGRAND

LEGRAND WIREMOLD XEVCABLE User manual

LEGRAND WIREMOLD MDSF User manual

LEGRAND

LEGRAND WIREMOLD MDSF User manual

LEGRAND RJ 45-Cat 5e User manual

LEGRAND

LEGRAND RJ 45-Cat 5e User manual

LEGRAND Linkeo C User manual

LEGRAND

LEGRAND Linkeo C User manual

LEGRAND Wiremold Walkerflex FCA User manual

LEGRAND

LEGRAND Wiremold Walkerflex FCA User manual

Popular Cables And Connectors manuals by other brands

Philips SWF1321 Specifications

Philips

Philips SWF1321 Specifications

Philips SWV2217NB Specifications

Philips

Philips SWV2217NB Specifications

Philips SWV6432 Specifications

Philips

Philips SWV6432 Specifications

Steren RAD-502 quick start guide

Steren

Steren RAD-502 quick start guide

Ag Leader EZ-Guide 250 installation instructions

Ag Leader

Ag Leader EZ-Guide 250 installation instructions

Lindy 43353 user manual

Lindy

Lindy 43353 user manual

Raychem pyrotenax Alloy 825 installation manual

Raychem

Raychem pyrotenax Alloy 825 installation manual

Cypress CLUX-14CEC Operation manual

Cypress

Cypress CLUX-14CEC Operation manual

3M 7620-S-2 instructions

3M

3M 7620-S-2 instructions

Philips SWV2432T Specifications

Philips

Philips SWV2432T Specifications

Comar Systems AST300 user manual

Comar Systems

Comar Systems AST300 user manual

Binary B-230-HDSPLTR-1x4 installation manual

Binary

Binary B-230-HDSPLTR-1x4 installation manual

Philips SWV3431S/10 user manual

Philips

Philips SWV3431S/10 user manual

Kyocera 5046 Series instruction manual

Kyocera

Kyocera 5046 Series instruction manual

RIDGID SeeSnake STANDARD Operator's manual

RIDGID

RIDGID SeeSnake STANDARD Operator's manual

Real-El OTG 0.1m user manual

Real-El

Real-El OTG 0.1m user manual

Cairn TWINCAM quick start

Cairn

Cairn TWINCAM quick start

Philips SWV2070NB Specifications

Philips

Philips SWV2070NB Specifications

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.