LEGRAND HPM EF150SQWE User manual

EF150SQWE
Standardsquare
150mm wallfan
EFS150SQWE
Standard
150mm wall fan
with autoshutter
Wall and Ceiling Exhaust Fan,150mm
Cat no. EF150SQWE, EF150SQSWE, EF150RDWE,
EFS150SQWE, EFS150SQSWE,
EFT150SQSWE, EFH150SQSWE
Instruction Manual
Specifications
For indoor use only. Airflow will be reduced with bends in duct, squashing of duct, restrictions on replacement air entering the room
to be ventilated, or pressure-differentials between the room and outside air. The length of the duct will have an effect on the airflow.
When fitted, the wall kit (R621/6D) must be at the same height or lower than the exhaust fan.
EF150SQSWE
Slimline square
150mm wallfan
EFS150SQSWE,
EFT150SQSWE,
EFH150SQSWE
Slimline 150mmwall
Fan with auto shutter
EF150RDWE
Round
150mm wallfan
Cat
no. EF150SQWE EF150SQSWE EF150RDWE EFS150SQWE EFS150SQSWE EFT150SQSWE/
EFH150SQSWE
Supply voltage
230–240V AC 50Hz
Power rating
24W max. 30W max.
Standby power
– – – – – 0.8W
Protection class
Class II
IP
rating IP44 IP24 IP44 IP24
Duct
requirement Ø150mm
Wall/ceiling
cut-out size Ø160mm
Draft stopper
PET Sheet Auto-Shutter (Wax Solenoid)
Fascia
Size
212x212mm Ø253mm 212x212mm
Thickness
43mm 24mm 43mm 24mm
Weight (excl.
packaging) 1.0kg 0.9kg 1.2kg 1.1kg
Sound Pressure Level
42 dBA at 3m (Tested in accordance with AS1217.5)
Cat
no. EF150SQWE EF150SQSWE & EF150RDWE EFS150SQWE
EFS150SQSWE
/EFT150SQSWE/
EFH150SQSWE
Draft stopper
with without with without with
No
duct 204 218 269 309 200 267
Wall
kitR621/6D
(350mm
ofduct) 184 189 206 217 184 206
1m of
duct 175 178 196 201 175 196
3m of
duct 158 160 171 181 158 171
Max Airflow (m3/hr)
Please read carefully: Read through these instructions completely before commencing installation. Retain for future use.
This product should be installed by a licensed electrical contractor or similarly qualified person.
1
CAUTION:
Regulations concerning the discharge of air must be fulfilled. Local building codes may require venting to the outside. Locate in accordance
with the requirements of the Wiring Rules AS/NZS 3000 relating to damp situations.
Note: Steam will only be removed if there is sufficient flow of air through the room. Ensure adequate inlet openings in the room are provided,
for example through windows, vents or under the door. Air-flow paths from room inlets to fan should ideally pass over surfaces where
condensation may form.
These exhaust fans are designed primarily for wall-mounting. They may be vented in to a cavity wall or in to the roof space in
the ceiling. Alternatively, the fan may be ducted through an outside wall (with the addition of ducting and an outside grille).
Protrusions into wall/ceiling cavity are as per below figures.
The flaps of the Auto-Shutter are driven by a thermoactuator. Due to this, the flaps will take time to open/close when the exhaust fan is
switched on/off.
Time to Open: 30 –60 seconds
Time to Close: 120 –200 seconds
250mm
96mm
Fan with duct
Duct
Ceiling
Fan with auto shutter
Fan only
Wall/Ceiling
160mm
Fan with draft stopper
Draft Stopper
Wall/Ceiling
Fan with auto shutter and duct
Duct
Ceiling
310mm
150mm
Wall/Ceiling
Auto-Shutter
When fitted, the duct outlet must be the same height or lower
than the exhaustfan.
The duct must not be installed vertically into a roof vent cap
–the product is not designed or intended for this type
of installation.
3Auto-Shutter (for EFS150SQWE, EFT150SQSWE,EFS150SQSWE & EFH150SQSWE)
2 Mounting
ROOF VENT CAP
ROOFING
4 Installation
Remove all packaging from the product before commencing installation. Ensure the circuit has been isolated from the 240V mains before
commencing work.
1. Choose a suitable mounting location. There must be adequate clearances in the wall/ceiling to accommodate the Draft-stopper and/or
ducting. Refer to section 2 for further information.
2. If ducting through the wall to the outside, refer to instructions in the wall duct kit. Note: the wall kit is available separately, please refer
to Optional Accessoriessection.
3. The time delay module that is included in EFT150SQSWE is available separately (EF100/150TD), adjustable from 1-to-29 minutes.
4. Make acircular 160mm hole in the wall/ceiling.
5. Remove front cover / fascia by removing fixing screw and cap on the underside of the cover.
6. Remove draft-stopper if not required. Note that the draft-stopper (when fitted) has an effect on the airflow.
7. Make the electrical connections (as per Figures below).
8. Ensure orientation of fan is with arrow pointing up.
9. Fix fan firmly to the wall with the 4 screws provided.
10. Replace front cover/fascia and tighten fixing screw. Replacecap.
11. Switch on and test function. Use a paper tissue held against fan
inlet to verifysuction.
Timer Adjustment
The default setting
is to 1min(approx).
Adjust to desired
time delay.
Active L
N
Neutral
TIMER
MINIMUM
(1 minute)
MAXIMUM
(29 minute)
Fan
mounting
orientation
LS Switched Active
from wall switch
NNeutral
L Unswitched Active
(only used when
timer module or
humidity sensor
module is fitted)
Cableentry
from rear
Cord entry from
side for plugand
lead (knock-out
provided)
Fixing screw
position offascia
Figure 1. Figure 2. Fan with Timer module and Light fitting
LS 3
N 2
L 1
C
ondition Timer Module Humidity sensor
LS is Powered OFF (Initial)
Fan does not run Fan does not run
LS is Powered ON
Fan runs continuously Fan runs continuously
LS is Powered OFF
Fan runs for Preset Time and Switches OFF
Fan runs if relative humidity is above preset
value and switches OFF when relative humidity
drops below the preset value plus 2 minutes.
LS is Powered ON and OFF immediately
Timer is Reset and fan runs for Preset Time and Switches OFF
LS is Powered OFF (continuously)
N/A
Fan will run if relative humidity reaches pre
-
set value and switches OFF when relative
humidity drops below the preset value plus 2
minutes. See optional switch in Fig.3 to disable
this function.
MINIMUM
60% RH
MAXIMUM
90% RH
Relative Humidity (RH)
Adjustment
The default factory setting is
90%. Adjust to desired RH level
Connection from rear –bring mains wiring through
cable entry hole.
Connection from side (Fan only) –use twin flat core
(H03VV-H2) or circular core (H05VV-F) 2 x 0.75mm2
and place under cable clamp provided.
Active L
N
Neutral
HUMIDITY SENSOR
Figure 3. Fan with Humidity Sensor module and Light fitting
Optional wall switch
LS
LS
Warranty
Legrand warrants this product for a period of 3 years from the date of purchase.
These goods come with guarantees that cannot be excluded under the Australian and
New Zealand Consumer Laws. You are entitled to a replacement or a refund for a major
failure and for compensation for any other reasonably foreseeable loss or damage.
You are also entitled to have the goods repaired if the goods fail to be acceptable quality
and the failure does not amount to a major failure.
See the Warranty card enclosed with this product for further details.
Customer Service
For all Customer Service and Technical Support
please call Monday to Friday during business hours.
Legrand Australia
1300 369 777
www.hpm.com.au
Legrand NewZealand
0800 476 009
www.hpm.co.nz
ABN: 31 000 102661
7 Disclaimers
1. This product must be installed and used as per these instructions.
2. This product is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person
responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
3. This product is intended for household use and similar purposes. It is not suitable for use in an environment heavily laden with dust.
Under these conditions the life of the fan motor can be significantly reduced.
4. This product should not be enclosed in thermal insulation as it may cause the unit to overheat.
5. This product has been designed to operate in ambient temperatures -10°C to 40°C.
6. This product contains no serviceable parts and no attempt should be made to repair it. If the product is faulty it should be discarded.
7. Airflows listed in this product indicate the product performance. Refer to the BCA (Building Code of Australia), or similar, for the
appropriate airflow required for a particular installation.
8. Ventilation products must have an adequate source of external air to ensure correct performance.
9. Consideration must be taken in the installation of ducts to ensure that condensation that will form in the duct will not run back into the
fan housing.
10. Precautions must be taken to avoid the back-flow of gases into the room from the open flue of gas or other fuel-burning appliances.
11.This product has been designed for domestic or similar uses and is not suitable for a commercial installation.
12.This product is not suitable for installation in hazardous and/or corrosive areas.
13. Extended exposure to UV rays (such as exposure to direct sunlight) may cause discolouration of this product.
14.The material in this product may vary in colour from batch to batch. Colour matching from one batch to another cannot be
guaranteed.
15.This product utilises intellectual property in the form of registered designs, trademarks, and/or patents. Such intellectual property
remains the property of Legrand in all cases.
16.Legrand reserves the right to modify the specification of this product at any time.
LE06397ATC
04_2019
6 Optional Accessories
R621/6D –150mm wall duct kit
EF100/150TD –Time delay module allows the fan to run for a set period, adjustable between 1 - 29 mins, after the switch has been turned off.
This product should only be cleaned with a damp cloth. Cleaning agents and solvents should not be used. Ensure the fan is switched off from
the mains power supply before removing the grille / fascia.
5Cleaning

This manual suits for next models

6

Other LEGRAND Fan manuals

LEGRAND HPM EFIL100SQWE User manual

LEGRAND

LEGRAND HPM EFIL100SQWE User manual

LEGRAND MIDDLE ATLANTIC UQFP Series User manual

LEGRAND

LEGRAND MIDDLE ATLANTIC UQFP Series User manual

LEGRAND HPM RCFTRI12H4WE User manual

LEGRAND

LEGRAND HPM RCFTRI12H4WE User manual

LEGRAND HPM EFD01RDWE User manual

LEGRAND

LEGRAND HPM EFD01RDWE User manual

LEGRAND HPM SERENE CF12AC4BLEDWE User manual

LEGRAND

LEGRAND HPM SERENE CF12AC4BLEDWE User manual

LEGRAND HPM Inspire RCF12H4WE User manual

LEGRAND

LEGRAND HPM Inspire RCF12H4WE User manual

LEGRAND HPM SERENE CF12DC4BWE User manual

LEGRAND

LEGRAND HPM SERENE CF12DC4BWE User manual

LEGRAND HPM EFTIL150SQWEKIT User manual

LEGRAND

LEGRAND HPM EFTIL150SQWEKIT User manual

LEGRAND Middle Atlantic EU Series User manual

LEGRAND

LEGRAND Middle Atlantic EU Series User manual

LEGRAND HPM Inspire RCFL12H4BTWE User manual

LEGRAND

LEGRAND HPM Inspire RCFL12H4BTWE User manual

LEGRAND HPM Inspire RCH12H4WE User manual

LEGRAND

LEGRAND HPM Inspire RCH12H4WE User manual

LEGRAND HPM RCF12H4WE User manual

LEGRAND

LEGRAND HPM RCF12H4WE User manual

LEGRAND CHIEF PACFAN1 User manual

LEGRAND

LEGRAND CHIEF PACFAN1 User manual

LEGRAND HPM CFSERACREMOTE User manual

LEGRAND

LEGRAND HPM CFSERACREMOTE User manual

LEGRAND HPM CFREMOTEH User manual

LEGRAND

LEGRAND HPM CFREMOTEH User manual

LEGRAND 0 677 66 User manual

LEGRAND

LEGRAND 0 677 66 User manual

LEGRAND HPM Serene CF12AC4BWE User manual

LEGRAND

LEGRAND HPM Serene CF12AC4BWE User manual

LEGRAND CHIEF CMS491 User manual

LEGRAND

LEGRAND CHIEF CMS491 User manual

LEGRAND MIDDLE ATLANTIC RESIDENTIAL UQFP Series User manual

LEGRAND

LEGRAND MIDDLE ATLANTIC RESIDENTIAL UQFP Series User manual

LEGRAND HPM EF100SQWE User manual

LEGRAND

LEGRAND HPM EF100SQWE User manual

LEGRAND VWMFK-115VAC User manual

LEGRAND

LEGRAND VWMFK-115VAC User manual

Popular Fan manuals by other brands

Silvercrest STV 45 D3 operating instructions

Silvercrest

Silvercrest STV 45 D3 operating instructions

Temspec VHC Series Operation & maintenance manual

Temspec

Temspec VHC Series Operation & maintenance manual

Monte Carlo Fan Company 8ATR44XXD-L Series Owner's guide and installation manual

Monte Carlo Fan Company

Monte Carlo Fan Company 8ATR44XXD-L Series Owner's guide and installation manual

ELTA FANS QUIETFLOW TWIN SQT Series Installation & maintenance

ELTA FANS

ELTA FANS QUIETFLOW TWIN SQT Series Installation & maintenance

Ensy AHU-200 KV SLIM User manual and installation guide

Ensy

Ensy AHU-200 KV SLIM User manual and installation guide

Vitek VT-1909 Manual instruction

Vitek

Vitek VT-1909 Manual instruction

Maico ER-A Installation and operating instructions

Maico

Maico ER-A Installation and operating instructions

McQuay MCC 010C/CR manual

McQuay

McQuay MCC 010C/CR manual

Exhale Fans EF34 Owner Guide & Installation Manual

Exhale Fans

Exhale Fans EF34 Owner Guide & Installation Manual

Emerson Northwind Contemporary Snugger CF805SAW01 owner's manual

Emerson

Emerson Northwind Contemporary Snugger CF805SAW01 owner's manual

NuAire XB-EFA-8L-GT Installation, Operating and Maintenance Instructions for the Installer and the User

NuAire

NuAire XB-EFA-8L-GT Installation, Operating and Maintenance Instructions for the Installer and the User

Panasonic FV-0511VFL1 installation instructions

Panasonic

Panasonic FV-0511VFL1 installation instructions

ZIEHL-ABEGG FB035 Assembly instructions

ZIEHL-ABEGG

ZIEHL-ABEGG FB035 Assembly instructions

KDK 23BWBH Installation and operating instructions

KDK

KDK 23BWBH Installation and operating instructions

Sinbo SF 6710 instruction manual

Sinbo

Sinbo SF 6710 instruction manual

Westinghouse Contempra IV IV-WH05 owner's manual

Westinghouse

Westinghouse Contempra IV IV-WH05 owner's manual

Honeywell HSF1640 Series manual

Honeywell

Honeywell HSF1640 Series manual

REMKO PWL Series Operating and installation instructions

REMKO

REMKO PWL Series Operating and installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.