Technical data
Te c h n ica lda ta
Leica DISTO™ X3 4
General
Accuracy with favourable conditions * 1 mm / 0.04" ***
Accuracy with unfavourable conditions ** 2 mm / 0.08" ***
Range with favourable conditions * 0.05 - 150m / 0.16 - 500ft ***
Range with unfavourable conditions ** 0.05 - 80m / 0.16 - 260ft ***
Smallest unit displayed 0.1 mm / 1/32 in
X-Range Power Technology yes
Laser class 2
Laser type 635 nm, <1 mW
ø laser point | at distances 6 /30 /60 mm | 10/ 50/ 100 m
Tilt measuring tolerance to laser beam **** ± 0.2°
Tilt measuring tolerance to housing **** ± 0.2°
Tilt measuring range **** 360°
Measuring range with Leica DST 360 horizontal ***** 360°
Measuring range with Leica DST 360 vertical ***** -64° to >90°
Tolerance P2P function at distances ***** ± 2 mm / 2 m | ± 5 mm / 5 m | ± 10 mm / 10 m
Protection class IP65 (dust- and splash water protected)
Auto. laser switch off after 90 s
Auto. power switch off after 180 s
Bluetooth® Smart Bluetooth® v4.0
Power of Bluetooth® Smart 0.71 mW
Frequency of Bluetooth® Smart 2400 - 2483.5 MHz
Range of Bluetooth® Smart <10m
* favourable conditions are: white and diffuse reflecting target (white painted wall), low background illu-
mination and moderate temperatures.
** unfavourable conditions are: targets with lower or higher reflectivity or high background illumination or
temperatures at the upper or lower end of the specified temperature range.
*** Tolerances apply from 0.05 m to 10 m with a confidence level of 95%.
With favourable conditions the tolerance may deteriorate by 0.10 mm/m for distances above 10 m.
With unfavourable conditions the tolerance may deteriorate by 0.15 mm/m for distances above 10 m.
**** after user calibration. Additional angle related deviation of +/-0.01° per degree up to +/-45° in each quad-
rant.
Applies at room temperature. For the whole operating temperature range the maximum deviation
increases by +/-0.1°.
***** In combination with Leica DST 360 adapter.
www.GlobalTestSupply.com