Table 1. Features and specifications
Microprocessor:
vIntel®Xeon®FC-LGA 771 dual-core
with 4MB Level-2 cache or
quad-core with 8MB (2x4 MB)
Level-2 cache
vSupport for up to two
microprocessors
vSupport for Intel Extended Memory
64 Technology (EM64T)
Notes:
1. Use the Configuration/Setup Utility
program to determine the type and
speed of the microprocessors.
2. For alist of supported
microprocessors, go to
http://www.lenovo.com/thinkserver.
Memory:
vTwelve DIMM connectors
vMinimum: 1GB
vMaximum: 48 GB
vType: Fully buffered DIMM (FBD)
PC2-5300 DIMMS only
vSizes: 1GB, 2GB, or 4GB (when
available), in pairs
vAdvanced ECC supported
Drives: CD/DVD: IDE 24x CD-RW/ 8x
DVD combination
Expansion bays:
vHot-swap hard disk drive bays: SAS
only. Number and size depend on the
server model. One of the following
configurations:
–Six 3.5-inch drive bays
–Eight 2.5-inch drive bays
–One 5.25-inch Ultrabay™
Enhanced bay (CD-RW/DVD drive
installed)
Expansion slots :
vTwo PCI Express x8 slots (x4 lanes)
on system board (low profile)
vSupport for either of the following
optional riser cards:
–Riser cards with two PCI Express
x8 slots (x8 lanes) (standard)
–Riser card with two 133
MHz/64-bit PCI-X slots
Hot-swap fans:
vStandard: Five
vMaximum: Ten -provide redundant
cooling
Hot-swap power supplies: 835 watts
(100 -240 Vac):
vMinimum: One
vMaximum: Two -provide redundant
power
Size (2U):
vHeight: 85.4 mm (3.36 in.)
vDepth: 705 mm (27.8 in.)
vWidth: 443.6 mm (17.5 in.)
vWeight: 21.09 kg (46.5 lb) to 29.03 kg
(64 lb) depending upon configuration
Integrated functions:
vBaseboard management controller
(BMC)
vTwo Broadcom 10/100/1000 Ethernet
controllers with TCP/IP Offload Engine
(TOE) support
vOne RAID controller, active only when
an 8k or 8k-l SAS controller is installed
vOne serial port
vOne serial-attached SCSI (SAS)
controller
vSeven Universal Serial Bus (USB) ports
(two on front and four on rear, plus one
internal), v2.0 supporting v1.1
vTwo video ports (one on front and one
on rear of server)
vOne internal serial AGA (SATA)
connector
vSupport for Remote Supervisor Adapter
II SlimLine (option)
Note: In messages and documentation,
the term service processor refers to the
baseboard management controller or the
optional Remote Supervisor Adapter II
SlimLine.
Video controller:
vATI RN50 video on system board
vCompatible with SVGA and VGA
v16 MB DDR video memory
Acoustical noise emissions:
vDeclared sound power, idle: 6.8 bel
vDeclared sound power, operating: 6.8
bel
ServeRAID SAS controller:
vServeRAID™-8k-l SAS Controller that
supports RAID levels 0, 1, 10
vUpgradeable to ServeRAID-8k SAS
Controller, 256 MB with battery backup, that
supports RAID levels 0, 1, 1E, 5, 6, and 10
Environment:
vAir temperature:
–Server on: 10° to 35°C (50° to 95°F)
Altitude: 0to 914.4 m(3000 ft)
–Server off: 10° to 43°C (50° to 109.4°F)
Maximum altitude: 2133.6 m(7000 ft)
–Shipping: -40° to 60°C (-40° to 140°F)
vHumidity (operating and storage):
–Server on: 8% to 80%
–Server off: 8% to 80%
Heat output:
Approximate heat output in British thermal
units (Btu) per hour:
vMinimum configuration: 1230 Btu per hour
(360 watts)
vMaximum configuration: 3390 Btu per hour
(835 watts)
Electrical input with hot-swap ac power
supplies:
vSine-wave input (50 or 60 Hz) required
vInput voltage and frequency ranges
automatically selected
vInput voltage low range:
–Minimum: 100 Vac
–Maximum: 127 Vac
v
Input voltage high range:
–Minimum: 200 Vac
–Maximum: 240 Vac
vInput kilovolt-amperes (kVA) approximately:
–Minimum: 0.29 kVA (all models)
–Maximum: 1.00 kVA
What your server offers
The server uses the following features and technologies:
vBaseboard management controller
The baseboard management controller (BMC) provides basic service-processor
environmental monitoring functions. If an environmental condition exceeds a
4ThinkServer RD120 Types 6444, 6445, 6446, and 6447: User Guide