manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Leviton
  6. •
  7. Remote Control
  8. •
  9. Leviton AC00R-10 User manual

Leviton AC00R-10 User manual

4-Way Wiring with Coordinating Remote
(no LEDs) Application:
3-Way or More Applications (Multi-location)
Dimmer and Switch Remotes
Cat. No. AC
ØØ
R-10, Coordinating Dimmer Remote (no LED’s)
Cat. No. AC
ØØ
R-1L, Matching Dimmer Remote (with LED’s)
Cat. No. AC
ØS
R-10, Coordinating Switch Remote (no LED’s)
Cat. No. AC
ØS
R-1L, Matching Switch Remote (with LED’s)
120VAC, 60Hz
INSTALLATION INSTRUCTIONS
Bl
PK-93620-10-00-0A-X1
Tools needed to install your Remote:
Slotted/Phillips Screwdriver Electrical Tape
Pliers Pencil
Cutters Ruler
INSTALLING YOUR REMOTE
NOTE: Use check boxes when Steps are completed.
WARNING: TO AVOID FIRE, SHOCK, OR DEATH;
TURN OFF POWER at circuit breaker or fuse and test
that power is off before wiring!
Identifying your wiring application (most
common):
NOTE: If the wiring in the wall box does not resemble
any of these configurations, consult a qualified electrician.
Step 2
Step 1
Step 3
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFFONOFF
ONOFF
ONOFF
ONOFF
ONOFF
3
5
1
2
6
4
4-Way
1. First Traveler – note color
2. Second Traveler – tagged
3. Neutral
4. Ground
5. Third Traveler – note color
6. Fourth Traveler – tagged
NOTE: For matching remote
w/LEDs installation, the First
Traveler becomes Line Hot.
√
Cut
(if necessary)
Installing your Alignment Plate:
Step 4
Step 5a
Side Wire Connection
Side wire terminals accept
#14 AWG
solid copper wire only.
Back Wire (either hole may
be used)
Back wire openings use #14-12
AWG
solid copper wire only.
•Make sure that the ends of the wires from the wall box are
straight (cut if necessary).
•Remove insulation from each wire in the wall box as shown.
WARNINGS AND CAUTIONS:
•To be installed and/or used in accordance with appropriate electrical codes and regulations.
•If you are unsure about any part of these instructions, consult a qualified electrician.
•To avoid overheating and possible damage to this device and other equipment, do not install to control a receptacle, fluorescent lighting, a motor- or a transformer-
operated appliance.
•For Hi-lume® or Eco-10™ (EcoSeries) electronic ballast applications, use instruction sheet that comes with the dimmer for multi-location applications.
•Acenti™ dimmers are not compatible with standard 3-way or 4-way switches. They must be used with compatible Acenti™ remotes for multi-location dimming.
WARNINGS AND CAUTIONS:
•Use only one (1) dimmer in a multi-location circuit with up to 9 coordinating remotes without LEDs or up to 4 matching remotes with LEDs.The remote(s) will turn the
light on at the brightness level selected at the dimmer.
•Recommended minimum wall box depth is 2-1/2".
•Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft.
•Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.
•Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.
Strip Gage (measure
bare wire here or use
gage on back of the
dimmer)
•For Incandescent and Magnetic Low-Voltage Applications, go
to appropriate Steps 5a-5d.
•For Electronic Low-Voltage, Electronic Switch, Mark 10™ and
Fan Speed Applications, go to appropriate Steps 5e-5h.
IMPORTANT:
For 3-Way applications, note that one of the screw terminals from
the old switch being removed will usually be a different color
(Black) or labeled Common. Tag that wire with electrical tape and
identify as the common (Line or Load) in both the dimmer wall box
and remote wall box.
For 4-Way applications, note that the old switch being removed
will have 4 screws plus a ground screw. Tag the two same color
insulated wires with electrical tape.
5/8"
(1.6 cm)
5/8"
(1.6 cm)
Important Notice for Installer
To achieve proper aesthetic installation of the Acenti
products, the wall surface surrounding the wall box opening
must be fairly flat and free of irregularities.The wall box must
be level and recessed or flush to the wall surface.The Acenti
installation system allows for adjustments that will correct
minor flaws that may be present in the installation area.
This device must be installed with the Acenti™ Alignment
Plate.The Alignment Plate is packaged with the Acenti™
Wallplate, which is sold separately from this device.
The Alignment Plate will function properly only if it is
mounted to a flat wall surface as described above.
•Leviton recommends to temporarily position the Alignment
Plate prior to wiring the device. If the wall box wires
extend at least 6 inches out of the wall box, it is also
possible to install the Alignment Plate after the device has
been wired (refer to Wallplate instruction sheet).
•The Alignment Plate must be installed with the tab
towards the bottom.
•Leviton recommends the following 3 methods to
temporarilyhold the Alignment Plate – use of device
mounting screw, use of wall box wires, or use of electrical
tape (refer to the following figures):
Step 4 cont’d
3-Way Wiring with Coordinating Remote
(no LEDs) Application:
BL
YL/RD RD
4
3
2
1
5
Terminal
Screw marked
Black (BL)
Terminal
Screw marked
Red (RD)
Terminal
Screw marked
Yellow/Red
(YL/RD)
Coordinating Remote Dimmer
2
BL
YL/RD
RD
4
3
5
1
2
4
1
5
3
3-Way
1. Line or Load
(See important
instruction below)
2. Neutral
3. Ground
4. First Traveler – note color
5. Second Traveler – note color
NOTE: For matching remote w/LEDs
installation, the First Traveler becomes
Line Hot.
Step 3 cont’d
Preparing and connecting wires:
This remote can be wired using side wire terminal
screws or through backwire openings. Choose
appropriate wire stripping specifications accordingly.
Strip Gage (measure
bare wire here or use
gage on back of the
dimmer)
NOTE: Incandescent and Magnetic Low-Voltage
installations only. NOTE: Screw terminal dimmer depicted.
WIRING DIMMER:
Connect wires per WIRING DIAGRAM as follows:
NOTE: When using the coordinating remote without LEDs, the dimmer can
be installed on either the Line or Load side of the 3-way circuit.
NOTE: Maximum wire length from dimmer to all installed remotes cannot
exceed 300 ft.
•Green or bare copper wire in wall box to Green terminal screw or
Green dimmer lead.
•Line Hot (common) wall box wire identified (tagged) when removing
old switch to dimmer terminal screw marked “BL” or Black dimmer lead.
•First Traveler wall box wire to terminal screw marked “RD” or Red
dimmer lead (note wire color). This traveler from the dimmer must go
to the terminal screw on the remote marked “RD”.
•Remove Red insulating label from terminal screw marked “YL/RD” or
Yellow /Red dimmer lead.
•Second Traveler wall box wire to terminal screw marked “YL/RD” or
Yellow/Red dimmer lead (note wire color). This traveler from the
dimmer must go to the terminal screw on the remote marked “YL/RD”.
WIRING COORDINATING REMOTE:
Connect wires per WIRING DIAGRAM as follows:
NOTE: Maximum wire length from dimmer to last remote is 300ft.
•Green or bare copper wire in wall box to Green terminal screw.
•Load wall box wire identified (tagged) when removing old switch to
terminal screw marked “BL”.
•First Traveler wall box wire (note color as above) to terminal screw
marked “RD”.This traveler from the remote must go to the terminal
screw on the dimmer marked “RD” or Red dimmer lead.
•Second Traveler wall box wire (note color as above) to terminal screw
marked “YL/RD”.This traveler from the remote must go to the terminal
screw on the dimmer marked “YL/RD” or Yellow/Red dimmer lead.
•Remote terminal screw marked "WH" should have White insulation
label affixed.
NOTE: If insulating label is not affixed to terminal screw marked "WH",
use electrical tape to cover.
•Proceed to Step 6.
Hot (Black)
Neutral (White)
Load
Control
Coordinating Remote (no LEDs)
YL/RD YL/RD
RD
WH
RD
BL
BL
Black
not used
White
Line
120VAC, 60Hz
Green
Ground
Green
Ground
Alignment Plate
Held By Tape
Alignment Plate
Held By Wires
Alignment Plate Held
By Mounting Screw
TOP
TOP
Mounting
Screw
Alignment
Plate
TOP
Electrical
Tape
Step 5b
BL
YL/RD RD
4
3
3
2
1
5
Terminal
Screw marked
Red (RD)
Terminal
Screw marked
Red (RD)
Terminal
Screw marked
Yellow/Red
(YL/RD)
Coordinating Remote
(3-Way Wall box from Step 2) Coordinating Remote
(4-Way Box from Step 2) Dimmer
(3-Way Wall Box from Step 2)
2
BL
YL/RD
RD
4
3
5
1
BL
YL/RD
RD
Terminal
Screw marked
Yellow/Red
(YL/RD)
Terminal
Screw marked
Red (RD)
6
2
15
NOTE: Incandescent and Magnetic Low-Voltage installations
only. NOTE: Screw terminal dimmer depicted.
Hot (Black)
Neutral (White)
Load
Dimmer
Coordinating Remote
(no LEDs)
Coordinating Remote
(no LEDs)
YL/RD
YL/RD YL/RD
RD
RD
WHWH
RD
BL
BL
BL
Black
not used
White
Line
120VAC, 60Hz
Green
Ground
Green
Ground
Green
Ground
not used
not used
WIRING COORDINATING REMOTE (4-Way box):
Connect wires per WIRING DIAGRAM as follows:
NOTE: Maximum wire length from dimmer to last remote is 300ft.
•Green or bare copper wire in wall box to Green terminal screw.
•First Traveler and Third Traveler wall box wire (note wire colors) to
terminal screw marked “RD”.These travelers from the remote in the 4-way
box must go to the terminal screw on the dimmer marked “RD”or Red
dimmer lead, and to the terminal screw marked “RD” of the remaining
remote in the 3-way box.
•Second Traveler (tagged) and Fourth Traveler (tagged) wall box wire (note
wire colors) to terminal screw marked “YL/RD”.These travelers from the
remote in the 4-way box must go to the terminal screw on the dimmer marked
“YL/RD” or theYellow/Red dimmer lead, and to the terminal screw marked
“YL/RD” of the remaining remote in the 3-way box.
•Remote terminal screw marked "WH" should have White insulation label
affixed.
NOTE: If insulating label is not affixed to terminal screw marked "WH",
use electrical tape to cover. Remote terminal screw marked “BL” is not used.
Use electrical tape to cover.
WIRING DIMMER (3-Way box):
Connect wires per WIRING DIAGRAM as follows:
NOTE: When using the coordinating remote without LEDs, the dimmer can be
installed on either the Line or Load side of the 3-way circuit.
NOTE: Maximum wire length from dimmer to all installed remotes cannot
exceed 300 ft.
•Green or bare copper wire in wall box to Green terminal screw or Green
dimmer lead.
•Line Hot (common) wall box wire identified (tagged) when removing
old switch to dimmer terminal screw marked “BL” or Black dimmer lead.
•First Traveler wall box wire to dimmer terminal screw marked “RD” or
Red dimmer lead (note wire color as above). This traveler from the
dimmer must go to the terminal screw on the remote marked “RD”.
•Remove Red insulating label from terminal screw marked “YL/RD” or
Yellow/Red dimmer lead.
•Second Traveler wall box wire to dimmer terminal screw marked “YL/RD”
or Yellow/Red dimmer lead (note wire color as above). This
traveler from the dimmer must go to the terminal screw on the
remote marked “YL/RD”.
WIRING COORDINATING REMOTE (3-Way box):
Connect wires per WIRING DIAGRAM as follows:
NOTE: Maximum wire length from dimmer to last remote is 300ft.
•Green or bare copper wire in wall box to Green terminal screw.
•Load wall box wire identified (tagged) when removing old switch to
terminal screw marked “BL”.
•First Traveler wall box wire (note color as above) to terminal screw
marked “RD”.This traveler from the remote must go to the terminal
screw on the dimmer marked “RD” or the Red dimmer lead.
•Second Traveler wall box wire (note color as above) to terminal screw
marked “YL/RD”.This traveler from the remote must go to the terminal
screw on the dimmer marked “YL/RD” or the Yellow/Red dimmer lead.
•Remote terminal screw marked "WH" should have White insulation
label affixed.
NOTE: If insulating label is not affixed to terminal screw marked "WH",
use electrical tape to cover.
•Proceed to Step 6.
3-WayWiring with Matching Remote (w/LEDs)
Application:
Step 5c
NOTE: Incandescent and Magnetic Low-Voltage installations
only. NOTE: Screw terminal dimmer depicted.
Hot (Black)
Neutral (White)
Load
Dimmer
Matching Remote (with LEDs)
YL/RD YL/RD
RD
WH
BL BL Black
White
Line
120VAC, 60Hz
Green
Ground
Green
Ground
BL
YL/RD RD
4
3
2
1
5
Additional
Neutral Wire
Matching Remote
(3-Way Wall box from Step 2) Matching Remote
(4-Way Wall box from Step 2) Dimmer
(3-Way Wall box from Step 2)
4
4
3
3
5
5
BL
YL/RD
WH
1
2
Additional
Neutral Wire
BL
YL/RD
WH
Terminal
Screw marked
Yellow/Red
(YL/RD)
Terminal
Screw marked
Black (BL)
Terminal
Screw marked
Yellow/Red
(YL/RD)
Terminal
Screw marked
Black (BL)
Terminal
Screw marked
White (WH)
Terminal
Screw marked
White (WH)
6
2
1
NOTE: The dimmer must be installed in a wall box that has a Load
connection. The matching remote must be installed in a wall box
with a Line Hot connection and a Neutral connection. A neutral wire
to the matching remote needs to be added as shown.
If you are unsure about any part of these instructions, consult a
qualified electrician.
NOTE: Maximum wire length from dimmer to all installed remotes cannot
exceed 300 ft.
WIRING MATCHING REMOTE (wall box with Line Hot connection):
Connect wires per WIRING DIAGRAM as follows:
•Green or bare copper wire in wall box to Green terminal screw.
•Line Hot (common) wall box wire identified (tagged) when removing
old switch and First Traveler to dimmer terminal screw marked "BL" or the
Black dimmer lead.
•Second Traveler wall box wire from dimmer to remote terminal screw marked
"YL/RD" (note wire color). This traveler from must go to the terminal
screw on the dimmer marked "YL/RD" or the Yellow/Red dimmer lead.
•Line Neutral wall box to remote terminal screw marked "WH".
WIRING DIMMER (wall box with Load connection):
Connect wires per WIRING DIAGRAM as follows:
•Green or bare copper wire in wall box to Green terminal screw or Green
dimmer lead.
•Load wall box wire identified (tagged) when removing old switch to
dimmer terminal screw marked "RD" or the Red dimmer lead.
•First Traveler Line Hot to dimmer terminal screw marked "BL" or the Black
dimmer lead.
•Remove Red insulating label from terminal screw marked "YL/RD" or
Yellow/Red dimmer lead.
•Second Traveler wall box wire (note color as above) to dimmer
terminal screw marked "YL/RD" or the Yellow/Red dimmer lead. This
traveler from the dimmer must go to the terminal screw on the remote
marked "YL/RD".
•Proceed to Step 6.
4-WayWiring with Matching Remote (w/LEDs)
Application:
Step 5d
NOTE: Incandescent and Magnetic Low-Voltage
installations only. NOTE: Screw terminal dimmer depicted.
Hot (Black)
Neutral (White)
Load
Dimmer
Matching Remote
(with LEDs) Matching Remote
(with LEDs)
YL/RD
YL/RD YL/RD
RD
WHWH
BLBL BL Black
White
Line
120VAC, 60Hz
Green
Ground
Green
Ground
Green
Ground
BL
YL/RD RD
4
3
2
1
5
Additional
Neutral Wire
Terminal
Screw marked
Black (BL)
Terminal
Screw marked
White (WH)
Terminal
Screw marked
Yellow/Red
(YL/RD)
DimmerMatching Remote
4
3
5
BL
YL/RD
WH
1
2
3-WayWiring with Matching Remote (w/LEDs)
for Controls with Neutral Connection Application:
4-Way Wiring with Coordinating Remote (no LEDs)
for Controls with Neutral Connection Application:
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a
description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, NewYork 11362-2591.This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used
under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. Leviton is not liable for incidental,
indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise. PK-93620-10-00-0A-X1
Step 5d cont’d
This traveler from the remotes must go to the terminal screw on the
dimmer marked “YL/RD” or theYellow/Red dimmer lead.
•Line Neutral wall box wire to remote terminal screw marked “WH”.
WIRING MATCHING REMOTE (3-Way wall box with Line Hot
connection):
Connect wires per WIRING DIAGRAM as follows:
•Green or bare copper wire in wall box to Green terminal screw.
•Line Hot (common) wall box wire identified (tagged) when removing
old switch and First Traveler dimmer terminal screw marked “BL” or the
Black dimmer lead.
•Second Traveler wall box wire from dimmer to remote terminal screw
marked "YL/RD" (note wire color as above). This traveler from
the remote must go to the terminal screw on the dimmer marked "YL/RD"
or the Yellow/Red dimmer lead.
•Line Neutral wall box wire to remote terminal screw marked “WH”.
WIRING DIMMER (3-Way wall box with Load connection):
Connect wires per WIRING DIAGRAM as follows:
•Green or bare copper wire in wall box to Green terminal screw or
Green dimmer lead.
•Load wall box wire identified (tagged) when removing old switch to
dimmer terminal screw marked "RD" or the Red dimmer lead.
•First Traveler Line Hot to dimmer terminal screw marked "BL" or the
Black dimmer lead.
•Remove Red insulating label from terminal screw marked "YL/RD" or
the Yellow/Red dimmer lead.
•Second Traveler wall box wire (note color as above) to dimmer
terminal screw marked "YL/RD" or theYellow/Red dimmer lead. This
traveler from the dimmer must go to the terminal screw on the remote
marked "YL/RD".
•Proceed to Step 6.
3-WayWiring with Coordinating Remote
(no LEDs) for Controls with Neutral Connection
Application:
Control
Coordinating Remote
BL WH
YL/RD
RD
3
5
1
2
3
4
5
Black
White
Green
Red
Yellow/Red
2
1
4
Terminal
Screw marked
White (WH)
Terminal
Screw marked
Yellow/Red
(YL/RD)
Step 5e
WIRING CONTROL:
Connect wires per WIRING DIAGRAM as follows:
NOTE: The control must be installed in a wall box that has a Line Hot Connection.
NOTE: Maximum wire length from control to all installed remotes cannot exceed
300 ft (90 m).
•Green or bare copper wire in wall box to Green terminal screw or Green
control lead.
•Line Hot (common) wall box wire identified (tagged) when removing
old switch to terminal screw marked “BL” or Black control lead.
•First Traveler wall box wire to terminal screw marked “RD” or Red control
lead (note wire color).
•Remove Red insulating label from terminal screw marked “YL/RD” or Yellow/
Red control lead.
•Second Traveler wall box wire to terminal screw marked “YL/RD” or Yellow/
Red control lead (note wire color). This traveler from the control must go to
the terminal screw on the remote marked "YL/RD".
•Line Neutral wall box wire to terminal screw marked “WH” or White control lead.
WIRING COORDINATING REMOTE:
Connect wires per WIRING DIAGRAM as follows:
NOTE: "BL" and "RD" terminals on coordinating remote are unused.
Tighten both screws.
NOTE: Maximum wire length from control to last remote is 300 ft (90 m).
•Green or bare copper wire in wall box to Green terminal screw.
•Load wall box wire identified (tagged) when removing old switch to
First Traveler (note color as above).
•Second Traveler wall box wire (note color as above) to terminal
screw marked “YL/RD”.This traveler from the remote must go to the terminal
screw marked “YL/RD” or Yellow/Red control lead.
Step 5e cont’d
Step 5f
WIRING COORDINATING REMOTE (4-Way box):
Connect wires per WIRING DIAGRAM as follows:
NOTE: “BL” and “RD” terminals on coordinating remote are unused.Tighten
both screws.
NOTE: Maximum wire length from dimmer to last remote is 300ft.
•Green or bare copper wire in wall box to Green terminal screw.
•Connect First Traveler wall box wire to Third Traveler wall box wire (note
wire colors) to terminal screw marked “RD” of remote in 4-way box, and to
terminal screw marked “RD” of the remaining remote in 3-way box.
•Connect Second Traveler and Fourth Traveler wall box wire (note wire
colors) to terminal screw marked “YL/RD” of remote in 4-way box, and to
terminal screw marked “YL/RD” of the remaining remote in 3-way box.
This traveler from the remotes must go to the terminal screw marked
“YL/ RD” orYellow/Red control lead.
•Remove White insulating label from terminal screw marked “WH”.
•Line Neutral wall box wire to terminal screw marked “WH”.
WIRING CONTROL (3-Way box):
Connect wires per WIRING DIAGRAM as follows:
NOTE: The control must be installed in a wall box that has a Line Hot
connection.
NOTE: Maximum wire length from control to all installed remotes cannot
exceed 300 ft.
•Green or bare copper wire in wall box to Green terminal screw or
Green control lead.
•Line Hot (common) wall box wire identified (tagged) when removing
old switch to terminal screw marked “BL” or Black control lead.
•First Traveler wall box wire to terminal screw marked “RD” or Red
control lead (note wire color as above).
•Remove Red insulating label from terminal screw marked “YL/RD” or
Yellow/Red control lead.
•Second Traveler wall box wire to terminal screw marked “YL/RD” or
Yellow/Red control lead (note wire color as above). This traveler from
the control must go to the terminal screw on the remote marked “YL/RD”.
•Line Neutral wall box wire to terminal screw marked “WH” or White control lead.
WIRING COORDINATING REMOTE (3-Way box):
Connect wires per WIRING DIAGRAM as follows:
NOTE: “BL” and “RD” terminals on coordinating remote are unused.Tighten
both screws.
NOTE: Maximum wire length from control to last remote is 300ft.
•Green or bare copper wire in wall box to Green terminal screw.
•Load wall box wire identified (tagged) when removing old switch to
First Traveler (note color as above).
•Second Traveler wall box wire (note color as above) to terminal screw
marked “YL/RD”.This traveler from the remote must go to the terminal screw
marked “YL/RD” or Yellow/Red control lead.
•Remove White insulating label from terminal screw marked “WH”.
•Line Neutral wall box wire to terminal screw marked “WH”.
•Proceed to Step 6.
BL WH
YL/RD
RD
3
5
1
2
3
4
5
Black
White
Green
Red
Yellow/Red
2
1
1
4
4
3
BL WH
YL/RD
RD
5
6
2
Terminal
Screw marked
White (WH)
Terminal
Screw marked
White (WH)
Terminal
Screw marked
Yellow/Red
(YL/RD)
Terminal
Screw marked
Black (BL)
Terminal
Screw marked
Yellow/Red
(YL/RD)
Terminal
Screw marked
Black (BL)
Coordinating Remote
(3-Way Wall box from Step 2) Coordinating Remote
(4-Way Box from Step 2) Control
(3-Way Wall Box from Step 2)
Hot (Black)
Neutral (White)
Control
Coordinating Remote
(no LEDs) Coordinating Remote
(no LEDs)
YL/RD
YL/RD Yellow/Red
RD
White
Red
Black
Black
BLWH
WH
White
Line
120VAC, 60Hz
Green
Ground
Green
Ground
Green
Ground
RD
not used
not used not used
not used
BL
Load
Step 5f cont’d
Step 5g
4
3
5
Additional
Neutral Wire
Control
Matching Remote
4
3
5
BL
YL/RD
WH
1
2
Black
Green
White
Red
Yellow/Red
1
2
Terminal
Screw marked
Black (BL)
Terminal
Screw marked
Red (RD)
Terminal
Screw marked
Yellow/Red
(
YL/RD
)
Hot (Black)
Neutral (White)
Control
cMat hing Remote (with LEDs)
YL/RD Yellow/Red
Red
WH
BL Black
Black
White
Load
Line
120VAC, 60Hz
Green
Ground
Green
Ground
White
NOTE: The control must be installed in a wall box that has a Load connection.
The matching remote must be installed in a wall box with a Line Hot
connection and a Neutral connection. A Neutral wire to the matching remote
needs to be added as shown.
If you are unsure about any part of these instructions, consult a qualified
electrician.
NOTE: Maximum wire length from control to all installed remotes cannot
exceed 300 ft (90 m).
WIRING MATCHING REMOTE (wall box with Line Hot
connection):
Connect wires per WIRING DIAGRAM as follows:
•Green or bare copper wire in wall box to Green terminal screw.
•Line Hot (common) wall box wire identified (tagged) when removing old
switch and First Traveler to terminal screw marked “BL” or Black dimmer lead.
•Second Traveler wall box wire from control to remote terminal
screw marked "YL/RD" (note wire color). This traveler from the
remote must go to terminal screw marked “YL/RD” or Yellow/Red control lead.
•Line Neutral wall box to remote terminal screw marked "WH".
WIRING CONTROL (wall box with Load connection):
Connect wires per WIRING DIAGRAM as follows:
•Green or bare copper wire in wall box to Green terminal screw or Green
control lead.
•Load wall box wire identified (tagged) when removing old switch to
terminal screw marked “RD” or Red control lead.
•First Traveler Line Hot to terminal screw marked “BL” or Black control lead.
•Remove Red insulating label from terminal screw marked “YL” or Yellow/
Red control lead.
•Second Traveler wall box wire (note color as above) to terminal screw
marked “YL/RD” or Yellow/Red control lead. This traveler from the control
must go to the terminal screw on the remote marked "YL/RD".
•Line neutral wall box wire to terminal screw marked“WH” or White control lead.
•Proceed to Step 6.
NOTE: The dimmer must be installed in a wall box that has a Load
connection. The matching remote must be installed in a wall box
with a Line Hot connection and a Neutral connection. A neutral wire
to the matching remote needs to be added as shown.
If you are unsure about any part of these instructions, consult a
qualified electrician.
NOTE: Maximum wire length from dimmer to all installed remotes cannot
exceed 300 ft.
WIRING MATCHING REMOTE (4-Way wall box with Line Hot
connection):
Connect wires per WIRING DIAGRAM as follows:
•Green or bare copper wire in wall box to Green terminal screw.
•First Traveler and Third Traveler wall box wire from dimmer in the 3-way
box to remote terminal screw marked “BL” in the 4-way box, and to the
terminal screw marked “BL” of the remaining remote in the 3-way box.
•Second Traveler (tagged) and Fourth Traveler (tagged) wall box wire from
dimmer in the 3-way box to remote terminal screw marked “YL/RD” in the
4-way box, and to the terminal screw marked “YL/RD” of the remaining
remote in the 3-way box (note wire colors).
•Remove White insulating label from terminal screw marked "WH".
•Line Neutral wall box wire to terminal screw marked "WH".
•Proceed to Step 6.
4-WayWiring with Matching Remote (w/LEDs) for
Controls with Neutral Connection Application:
Step 5h
4
3
5
Additional
Neutral Wire
4
3
5
BL
YL/RD
WH
1
2
Black
Green
White
Red
Yellow/Red
1
2
4
3
BL WH
YL/RD
RD
2
Terminal
Screw marked
White (WH)
Terminal
Screw marked
White (WH)
Terminal
Screw marked
Yellow/Red
(YL/RD)
Terminal
Screw marked
Black (BL)
6
1
5
Matching Remote
(3-Way Wall box from Step 2) Matching Remote
(4-Way Box from Step 2) Control
(3-Way Wall Box from Step 2)
Terminal
Screw marked
Yellow/Red
(YL/RD)
Terminal
Screw marked
Black (BL)
Hot (Black)
Neutral (White)
Control
Matching Remote
(with LEDs)
Matching Remote
(with LEDs)
YL/RD
YL/RD Yellow/Red
Red
WH White
WH
BLBL Black
Line
120VAC, 60Hz
Green
Ground
Green
Ground
Green
Ground
Black
White
Load
NOTE: The control must be installed in a wall box that has a Load
connection. The matching remote must be installed in a wall box with a Line
Hot connection and a Neutral connection. A neutral wire to the matching
remote needs to be added as shown.
If you are unsure about any part of these instructions, consult a qualified electrician.
NOTE: Maximum wire length from control to all installed remotes cannot
exceed 300 ft.
WIRING MATCHING REMOTE (4-Way wall box with Line Hot
connection):
Connect wires per WIRING DIAGRAM as follows:
•Green or bare copper wire in wall box to Green terminal screw.
•First Traveler and Third Traveler wall box wire to remote terminal screw
marked “BL” in 4-way box, and to terminal screw marked “BL” of the remaining
remote in 3-way box.
•Second Traveler (tagged) and Fourth Traveler (tagged) wall box wire from
control in 3-way box to remote terminal screw marked “YL/RD” in 4-way box.
and to terminal screw marked “YL/RD” of the remaining remote in 3-way box
(note wire colors). This traveler from the remotes must go to the terminal
screw marked “YL/RD”or Yellow/Red control lead.
•Line Neutral wall box wire to remote terminal screw marked “WH”.
WIRING MATCHING REMOTE (3-Way wall box with Line Hot
connection):
Connect wires per WIRING DIAGRAM as follows:
•Green or bare copper wire in wall box to Green terminal screw.
•Line Hot (common) wall box wire identified (tagged) when removing old
switch and First Traveler wall box wire to control terminal screw marked
“BL” or Black dimmer lead.
•Second Traveler wall box wire from control to remote terminal screw marked
"YL/RD" (note wire color as above). This traveler from the remote must go
to the terminal screw marked “YL/RD” or Yellow/Red dimmer lead.
•Line Neutral wall box wire to remote terminal screw marked “WH”.
WIRING CONTROL (3-Way wall box with Load connection):
Connect wires per WIRING DIAGRAM as follows:
•Green or bare copper wire in wall box to Green terminal screw or Green
dimmer lead.
•Load wall box wire identified (tagged) when removing old switch to
terminal screw marked “RD” or Red control lead.
•First Traveler Line Hot to terminal screw marked “BL” or Black control lead.
•Remove Red insulating label from terminal screw marked “YL/RD” or Yellow/
Red control lead.
•Second Traveler wall box wire (note color as above) to terminal screw
marked “YL/RD” or Yellow/Red control lead. This traveler from the control
must go to the terminal screw on the remote marked "YL/RD".
•Line Neutral wall box wire to terminal screw marked “WH” or White control lead.
•Proceed to Step 6.
Hot (Black)
Neutral (White)
Control
Coordinating Remote (no LEDs)
YL/RD Yellow/Red
RD
White
Red
Black
Black
BLWH
White
Load Line
120VAC, 60Hz
Green
Ground
Green
Ground
not used
not used
Testing your Remote prior to completely
mounting in wall box:
•If Alignment Plate is temporarily positioned using screw as in
Step 4A, remove screw at this point.
•Position all wires to provide room in outlet wall box for device.
•Ensure that the word "TOP" is facing up on the device strap.
•Partially screw in mounting screws in wall box mounting hole.
Step 5g cont’d Step 6
NOTE: Dress wires with a bend as shown in diagram in order to
relieve stress when mounting device.
•Restore power at circuit breaker or fuse.
•See applicable operation section to
ensure dimmer or switch is functioning
properly.
If lights do not turn ON, refer to the
TROUBLESHOOTING section.
TOP
TOP
Locator Light
To complete the Acenti™ Dimmer and Wallplate installation,
please refer to the instructions included with the Acenti™
Wallplate and Alignment Plate.
Remote Mounting:
TOP
TOP
Wall Surface
Alignment Hole
(2 places)
Mounting Screw
(2 places)
Alignment Pin
(2 places)
Mounting Screw
(remove if applicable)
Step 7
OPERATION
NOTE: This device has a removable push pad. If there is a need to re-
install the push pad, proceed as follows:
•Line up tabs located on top back of pad with
openings in the top of strap and gently press in.
•Line up tab located on bottom back of pad with opening in the
bottom of strap and gently press in.
•Press bottom of push pad to re-engage.
CLEANING: Clean with a damp cloth. DO NOT use chemical cleaners.
AC00R-10 Coordinating Dimmer Remote Operation:
NOTE: The lights will turn ON at brightness set on dimmer's DIM/
BRIGHT bar.The lighting can be controlled from either the dimmer or
the remote location.
AC0SR-10 Coordinating Switch Remote Operation:
ADVANCED PROGRAMMING FEATURES
ADVANCED PROGRAMMING FEATURES
Push Pad (Default settings)
Turn ON from OFF position:
Tap – Lights turn ON to preset level.
Press and Hold – Lights turn ON to full bright.
Turn OFF from ON position:
Tap – Lights turn OFF.
Press and Hold for 2 seconds – Lights remain
ON for 10 seconds and then turn OFF.
DIM/BRIGHT Bar
BRIGHTEN:
Press DIM/BRIGHT Bar Up Arrow –
Lights brighten to desired level.
DIM:
Press DIM/BRIGHT Bar Down Arrow – Lights
dim to desired level.
If you continue to hold, the lights will DIM to
minimum level and then turn OFF.
Push Pad (Default settings)
Turn ON from OFF position:
Tap – Lights turn ON to preset level.
Turn OFF from ON position:
Tap – Lights turn OFF.
DIM/BRIGHT
Bar
Push
Pad
Push
Pad
AC00R-1L Matching Dimmer Remote Operation:
NOTE: The locator light will illuminate when the load is in the OFF
position to facilitate access in the dark.
NOTE: The lights will turn ON at brightness set on the DIM/BRIGHT
bar.The lighting can be controlled from either the dimmer or the
remote location.
Push Pad (Default settings)
Turn ON from OFF position:
Tap – Lights turn ON to preset level.
Press and Hold – Lights turn ON to full bright.
Turn OFF from ON position:
Tap – Lights turn OFF.
Press and Hold until LED in LED Brightness
Display starts to blink – Lights remain ON for
10 seconds and turn OFF.
DIM/BRIGHT Bar
BRIGHTEN:
Press DIM/BRIGHT Bar Up Arrow –
Lights brighten to desired level.
DIM:
Press DIM/BRIGHT Bar Down Arrow – Lights
dim to desired level.
If you continue to hold, the lights will DIM to
minimum level and then turn OFF.
NOTE: When lights are OFF you can change
the light level that the lights will turn ON to
using the DIM/BRIGHT Bar.
DIM/BRIGHT
Bar
LED
Brightness
Display
Push
Pad
Locator
Light
Push Pad (Default settings)
Turn ON from OFF position:
Tap – Lights turn ON to preset level.
Turn OFF from ON position:
Tap – Lights turn OFF.
Push
Pad
AC0SR-1L Matching Switch Remote Operation:
NOTE: The locator light will illuminate when the load is in the OFF
position to facilitate access in the dark.
Locator
Light
If there is a power outage, the lights will return
to the last setting before the power
interruption, when the power is restored.
If there is a power outage, the lights will return to the last setting
before the power interruption, when the power is restored.
If there is a power outage, the lights will return to the last setting before
the power interruption, when the power is restored.
If there is a power outage, the lights will
return to the last setting before the power
interruption, when the power is restored.
TROUBLESHOOTING
•Lights Flickering
- Lamp has a bad connection.
- Wires not secured firmly under terminal screws of dimmer and/
or remote.
•Light does not turn ON and Locator LED does not
turn ON
- Circuit breaker or fuse has tripped.
- Lamp is burned out.
- Lamp Neutral connection is not wired.
•Intermittent dimmer operation
- Minimum load is under 40W.
•Remote does not operate lights
- Ensure that total wire length does not exceed 300 ft.
For additional information, contact the Acenti™
Information Hotline at
1-888-4-ACENTI
or visit
Leviton's website at
www.leviton.com/acenti
U.S. & Foreign Patents Pending
Copyright©2004 Leviton Manufacturing Co., Inc.
All Rights Including Trade Dress Rights Reserved
Eco-10™ (Eco Series) is a trademark and Hi-lume®is a
registered trademark of Lutron Electronics Inc.
FCC COMPLIANCE STATEMENT
This equipment has been tested and found to comply with the limits for a Class B Digital
Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation.This
equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment OFF an ON, the
user is encouraged to try to correct the interference by one or more of the following
measures:
•Reorient or relocate the receiving Antenna.
•Increase the separation between the equipment and the receiver.
•Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
•Consult the dealer or an experienced radio/tv technician for help.
NOTE: Electronic Low-Voltage, Mark 10™, Quiet Fan Speed and
Electronic Switch installations only. NOTE: Dimmer is depicted.
NOTE: Electronic Low-Voltage, Mark 10™, Quiet Fan Speed and
Electronic Switch installations only. NOTE: Dimmer is depicted.
NOTE: Electronic Low-Voltage, Mark 10™, Quiet Fan Speed and
Electronic Switch installations only. NOTE: Dimmer is depicted.
NOTE: Electronic Low-Voltage, Mark 10™, Quiet Fan Speed and
Electronic Switch installations only. NOTE: Dimmer is depicted.
NOTE: Matching Dimmer Remote depicted.

This manual suits for next models

3

Other Leviton Remote Control manuals

Leviton HCCUR User manual

Leviton

Leviton HCCUR User manual

Leviton JCC JC121371 User manual

Leviton

Leviton JCC JC121371 User manual

Leviton VIZIA RF + User manual

Leviton

Leviton VIZIA RF + User manual

Leviton 48A00-1 Operation and maintenance manual

Leviton

Leviton 48A00-1 Operation and maintenance manual

Leviton ZLS0R-RC1 User manual

Leviton

Leviton ZLS0R-RC1 User manual

Leviton DL15A User manual

Leviton

Leviton DL15A User manual

Leviton RZCS1 User manual

Leviton

Leviton RZCS1 User manual

Leviton Universal Remote Controle User manual

Leviton

Leviton Universal Remote Controle User manual

Leviton Sector SHH00-000 User manual

Leviton

Leviton Sector SHH00-000 User manual

Leviton Vizia RF RZCPG User manual

Leviton

Leviton Vizia RF RZCPG User manual

Leviton Acenti ACP0R-CB User manual

Leviton

Leviton Acenti ACP0R-CB User manual

Leviton HCCUR User manual

Leviton

Leviton HCCUR User manual

Leviton VRCPG User manual

Leviton

Leviton VRCPG User manual

Leviton Enocean WSTLT-9D0 User manual

Leviton

Leviton Enocean WSTLT-9D0 User manual

Leviton Decora IllumaTech RTF01-10X User manual

Leviton

Leviton Decora IllumaTech RTF01-10X User manual

Leviton NE200 User manual

Leviton

Leviton NE200 User manual

Leviton Bitwise BWRMT User manual

Leviton

Leviton Bitwise BWRMT User manual

Leviton HCCUR User manual

Leviton

Leviton HCCUR User manual

Leviton 8700 Series User manual

Leviton

Leviton 8700 Series User manual

Leviton VRCPG User manual

Leviton

Leviton VRCPG User manual

Leviton Vizia VZ00R-10X User manual

Leviton

Leviton Vizia VZ00R-10X User manual

Leviton NE210 User manual

Leviton

Leviton NE210 User manual

Leviton HCCKR User manual

Leviton

Leviton HCCKR User manual

Popular Remote Control manuals by other brands

Hisense 32K26 Important information

Hisense

Hisense 32K26 Important information

RadioLink TrackStar D-Spec TS4G instruction manual

RadioLink

RadioLink TrackStar D-Spec TS4G instruction manual

BenQ MR1 user manual

BenQ

BenQ MR1 user manual

RCA RTD315 Quick installation guide

RCA

RCA RTD315 Quick installation guide

RCA RCR503BR Code List

RCA

RCA RCR503BR Code List

LEGRAND Qmotion QDR2 Re)Programming Guide

LEGRAND

LEGRAND Qmotion QDR2 Re)Programming Guide

Excalibur RS-251-EDP Operation guide

Excalibur

Excalibur RS-251-EDP Operation guide

dji PVT581 user manual

dji

dji PVT581 user manual

Cervis Warrior 32 HH2S-9XL10 manual

Cervis

Cervis Warrior 32 HH2S-9XL10 manual

URC HS-R100 owner's manual

URC

URC HS-R100 owner's manual

FrSky HORUS X12S manual

FrSky

FrSky HORUS X12S manual

Gimson Robotics GLA-CU-X2 Setup guide

Gimson Robotics

Gimson Robotics GLA-CU-X2 Setup guide

CompuSTAR SLICE 2W940R-SS user guide

CompuSTAR

CompuSTAR SLICE 2W940R-SS user guide

AC Air Technology AC TRACKTECH T1X4 instruction manual

AC Air Technology

AC Air Technology AC TRACKTECH T1X4 instruction manual

Sony RMF-TX100U owner's manual

Sony

Sony RMF-TX100U owner's manual

Toshiba TCB-SC642TLE owner's manual

Toshiba

Toshiba TCB-SC642TLE owner's manual

Philips SRU6080 Specifications

Philips

Philips SRU6080 Specifications

Jumper T8SG Lite quick start guide

Jumper

Jumper T8SG Lite quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.