A) If using a Leviton Z-WaveTM Programmer/Remote, Cat. No. RZCPG,
press the Menu button and scroll down to System Setup. Press the
center button to select System Setup Menu. Press the center button
to select Network. Scroll down to <Exclude Node> and press the
center button.
B) If using RZCPG Programmer/Remote, you will be prompted to place
1-scene controller into programming mode.
C) To access Program mode, engage the air gap switch by gently
pulling the bottom of the push pad until it lifts out of the frame and a
click is heard (refer to figure). Wait 5 seconds and then press the
push pad back into the frame and hold push pad until the LED turns
Amber. Release the push pad and the LED should blink Amber. You
are now in Programming mode.
NOTE: If the LED on the 1-scene controller turns solid Red while
excluding, there has been a communication error.
D) While standing close to the 1-scene controller (approximately 2-5 ft.),
press the center button to <Exclude> device from the network.
Factory Default:
If your 1-scene controller is not responding,
or you are unable to control it after you
have tried to Include/Exclude it multiple
times, it may be necessary to reset the
1-scene controller to its original factory
settings. To accomplish this, proceed as
follows:
• On the 1-scene controller, engage
the air-gap switch by gently pulling
the bottom of the push pad until it lifts
completely out of the frame and a
click is heard (refer to figure). Wait 5
seconds and then press the push pad
back into the frame and hold push pad
until the locator LED turns Amber and then
turns solid Red. The 1-scene controller is now
reset. Once the controller is reset, it will be
necessary to Re-Include it to a network before it can be used.
CAUTION: SETTING A DEVICE TO A FACTORY DEFAULT DOES
NOT EXCLUDE THAT DEVICE FROM A NETWORK. THE EXCLUSION
PROCEDURE MUST STILL BE FOLLOWED TO REMOVE THE DEVICE
FROM THE PRIMARY PROGRAMMER/REMOTE'S INFORMATION
TABLE. FAILURE TO DO SO MAY RESULT IN SYSTEM THAT IS SLOW
TO RESPOND, OR MAY FAIL TO RESPOND TO SOME DEVICES. DI-000-RZCS1-00C
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement,
at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591. This warranty excludes and there is disclaimed liability
for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or
implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. Leviton is not liable for incidental,
indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
Restore Power:
Restore power at circuit breaker or fuse.
Installation is complete.
Step 6 cont'd
Programmer/Remote
Cat. No. RZCPG
NOTE: Programmer/Remote must be
in close proximity to 1-scene controller
when including in the network.
Step 7 Excluding 1-Scene Controller from
Z-WaveTM Network:
For additional information, contact Leviton’s
Techline at 1-800-824-3005 or visit Leviton’s
website at www.ViziaRF.com
Protected under U.S. Patent Number 6,388,399 and patents pending and
licensed under U.S. Patents Numbers 5,905,442, and 5,982,103
This equipment has been tested and found to comply with the limits for a
Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment
OFF and ON, the user is encouraged to try to correct the interference by
one or more of the following measures:
• Reorient or relocate the receiving Antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
• Consult the dealer or an experienced radio/tv technician for help.
FCC COMPLIANCE STATEMENT
Push
Pad
LED
Matching Remote Application:
Push Pad (Default settings)
Turn ON from OFF position:
Tap – Lights turn ON, LED turns OFF.
Turn OFF from ON position:
Tap – Lights turn OFF, LED turns ON.
Scene Application:
Push Pad (Default settings)
Turn ON from OFF position:
Tap – Scene is activated, Scene LED turns ON.
LED will blink until Scene is reached.
NOTE: While LED is blinking, a button press
will be ignored.
Turn OFF from ON position:
Tap – Scene is no longer activated, Scene LED
turns OFF.
If there is a power outage, when the power is
restored, the lights will return to the last setting
before the power interruption.
Cleaning: Clean with a damp cloth. DO NOT
use chemical cleaners.
OPERATION
TROUBLESHOOTING
• Locator LED on controller does not turn ON
- Circuit breaker or fuse has tripped.
- If 1-scene controller is powered up and LED does not turn ON,
check wiring.
• Scene controller does not operate lights
- Check association.
- Ensure that controller was properly updated.
Gently lift bottom of
push pad out
Including 1-Scene Controller into
Z-WaveTM Network: Step 8 Device Association:
After inclusion process, you must associate the devices to
the controllers. Refer to the Primary Programmer/Remote
instruction sheet for complete details.
Step 9 1-Scene Controller Mounting:
TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.
Installation may now be completed by
tightening mounting screws into wall box.
Attach wallplate.
Step 10
NOTE: One (1) Z-WaveTM device can be associated to multiple programmer/
remotes (up to five (5) programmer/remotes maximum).
NOTE: If using a non-Leviton Programmer/Remote, refer to the
Programmer/Remote instruction sheet for Associating a device.
Once association is complete, you can set a scene as follows:
• Press and hold button on 1-Scene Controller until LED blinks Green.
• Adjust devices in area.
• Press button again on 1-Scene Controller and the LED will stop blinking.
• The scene has now been set.
NOTES