FACTORY DEFAULT
Devices are programmed to automatically time-out of any settings after 20 seconds.
EXITING PROGRAMMING
When removing a device from a network it is best practice to use the Exclusion process. In
situations where a device needs to be returned to factory default follow the following steps:
• Holding the control button for a total of 14 seconds.
- After the first 7 seconds the LED turns amber.
- The Locator LED will quickly flash red/amber after 14 seconds.
• Release the control button and the device will reset.
DI-000-DL15A-02A-X3
If the plug-in outlet appears to be functioning improperly, proceed with the following
steps:
1. Confirm that the device is being supplied from a 120V AC, 60Hz source ONLY.
2. Confirm that the load being controlled is in proper working order (local switch is ON)
and check for burned-out bulbs.
TROUBLESHOOTING
© 2016 Leviton Mfg. Co., Inc.
FOR CANADA ONLY
For additional information, contact Leviton’s Techline at
1-800-824-3005 or visit Leviton’s website at www.leviton.com
For warranty information and/or product returns, residents of Canada should contact
Leviton in writing at Leviton Manufacturing of Canada Ltd to the attention of the
Quality Assurance Department, 165 Hymus Blvd, Pointe-Claire (Quebec), Canada
H9R 1E9 or by telephone at 1-800-405-5320.
This device complies with Part 15 of the FCC Rules. Operation is subject to following
two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation of the device.
This equipment has been tested and found to comply with the limits for a Class B Digital
Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment OFF and ON,
the user is encouraged to try to correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving Antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/tv technician for help.
FCC CAUTION
Any changes or modifications not expressly approved by Leviton Manufacturing Co.,
Inc., could void the user's authority to operate the equipment.
FCC COMPLIANCE STATEMENT
Copyright and Trademark Information
Decora and Lumina are registered trademarks of Leviton Manufacturing Co., Inc.
Use herein of other third party trademarks, service marks, trade names, brand names
and/or product names are for informational purposes only, are/may be the trademarks
of their respective owners; such use is not meant to imply affiliation, sponsorship, or
endorsement. No part of this document may be reproduced, transmitted or transcribed
without the express written permission of Leviton Manufacturing Co., Inc.
This product is covered by U.S. Patent No. 8,664,886 and corresponding foreign
patents.
IC COMPLIANCE STATEMENT
This device complies with Industry Canada licence-exempt RSS standard(s). Operation
is subject to the following two conditions: (1) this device may not cause interference,
and (2) this device must accept any interference, including interference that may cause
undesired operation of the device.
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship
under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option. For details visit www.
leviton.com or call 1-800-824-3005. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product
is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in
accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied
warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. Leviton
is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or
delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
MULTI-WAY APPLICATIONS
Leviton LuminaTM RF devices can be used in multi-way applications. Virtual 3 or
4 way scenarios can be created without a traveler conductor between switches.
One device controls the load and additional switches provide additional control
locations. Each additional location only requires a hot and neutral, the load
control conductor is not used.
To create a virtual 3-way is a multi-step process. For bidirectional communication
each location is set to master and paired to additional control locations:
Choose a control location to be the master. The master location will not be placed
into pairing mode, it will be used in the second step.
Step 1: Placing additional locations into pairing mode:
• Enter Programming Mode by holding the top of the paddle for 7 seconds, the Locator
LED will blink amber.
• Tap the top of the paddle 2 times.
The Locator LED will flash red indicating the device is waiting to be paired.
• If the multi-way application is greater than two total devices, place each addition
location in pairing mode.
• When all pairing locations are ready move to the master location.
Step 2: Binding the master to the devices in pairing mode:
With each of the additional control locations in pairing mode bind the master.
• Enter Programming Mode by holding the top of the paddle for 7 seconds, the Locator
LED will blink amber.
• Tap the top of the paddle 3 times.
• The Locator LED will blink amber for an instant.
• The LED will flash green if pairing devices are found.
• The LED will flash red if pairing devices are not found.
Once binding is complete the paired locations will follow the master station button
presses. To allow paired locations to act as a master, repeat the sequence above with
the new location master. The process can be repeated until all locations have been the
master providing a complete multi-way application.
NOTE: The binding between a master and remote can be removed by repeating the
binding process. When the binding process is run and the devices are currently bound,
the binding is removed.