DL2 system
To learn more about LINAK please visit:
WWW.LINAK.COM
USER MANUAL

2

3
Preface ..................................................................................................................................................................4
Safety instructions...............................................................................................................................................5
Before installation, reinstallation or troubleshooting ......................................................................................5
Before start-up .....................................................................................................................................................5
During operation .................................................................................................................................................5
Repairs ..................................................................................................................................................................6
Manufacturer’s declaration .................................................................................................................................6
Misc. on the DESKLINE®system ..........................................................................................................................7
Warranty...............................................................................................................................................................7
Maintenance.........................................................................................................................................................7
Mounting guidelines for DL2 with CBD2N control box ....................................................................................9
Bending moment...........................................................................................................................................10
Mounting guidelines CBD2N .........................................................................................................................11
Electrical connection of the DL2 system .........................................................................................................12
Operation with SLS........................................................................................................................................14
Description of the DESKLINE®DL2 Memory System with CBD2 E/F/G ..........................................................15
Mounting guidelines for DL2 system..............................................................................................................16
Bending moment...........................................................................................................................................17
Mounting guidelines CBD2 E/F/G...................................................................................................................18
Electrical connection of the DL2 system .........................................................................................................19
Initialisation of the DESKLINE DL2 system.......................................................................................................21
Operation with SLS........................................................................................................................................22
Disposal of LINAK’s products ............................................................................................................................23
Label ...................................................................................................................................................................24
Drawing appendix .............................................................................................................................................25
Addresses ...........................................................................................................................................................28
Contents

4
Preface
We are delighted that you have chosen a product from LINAK A/S. LINAK systems
are high-tech products based on many years of experience in the manufacture and
development of actuators, electric control boxes, controls and chargers. We are also
constantly improving our products to meet customer requirements.
This User Manual will tell you how to install, use and maintain your LINAK
DESKLINE®products.
We are sure that the DESKLINE®products will give you many years of problem-free
operation. Before our products leave the factory they undergo full function and
quality testing. Should you nevertheless experience problems with your systems,
you are always welcome to contact our service departments or service centres.
LINAK subsidiaries and distributors all over the world have authorised service
centres, which are always ready to help you.
LINAK provides a warranty on all its products. This warranty, however, is subject to
correct use in accordance with the specifications, maintenance being done correctly
and any repairs being carried out at a service centre, which is authorised to repair
LINAK products.
Changes in installation and use of LINAK systems can affect their operation and
durability. Changes must therefore only be made by agreement with LINAK A/S and
are made at your own risk.
LINAK A/S

5
Safety instructions
Failure to comply with instructions marked with the warning symbol may result in
accidents involving serious personal injury.
Failure to comply with instructions marked with the ”NOTE” symbol may result in
serious damage to the system or one of its components.
Persons who do not have the necessary experience or knowledge of the product/
products must not use the product/ products. Besides, persons with reduced
physical or mental abilities must not use the product/products, unless they are
under surveillance or they have been thoroughly instructed in the use of the
apparatus by a person who is responsible for the safety of these persons.
Moreover, children must be under surveillance to ensure that they do not play with
the product.
It is important for everyone who is to connect, install or use the systems to
have the necessary information and access to this User Manual.
If there is visible damage on the product it must not be installed.
The appliance is not intended for use by young children or infirm persons
without supervision.
Young children should be supervised to ensure that they do not play with the
appliance.
Before installation, de-installation or troubleshooting:
• Stop the DL2
• Switch off the power supply and pull out the mains plug.
• Relieve the DL2 of any loads, which may be released during the work.
Before start-up:
• Make sure that the system has been installed as instructed in this User Manual.
• Make sure that the voltage at the control box is correct before the system is
connected to the mains.
• System connection. The individual parts must be connected before the control
box is connected to the mains. See the User Manual for LINAK actuators, if
necessary.
During operation
• If the control box makes unusual noises or smells switch off the mains voltage
immediately.
• Take care that the cables are not damaged.
• Unplug the mains cable on mobile equipment before it is moved.
• The products must only be used in an environment, which corresponds to their IP
protection.

6
Repairs
In order to avoid the risk of malfunction, all DESKLINE®repairs must only be carried
out by authorised LINAK workshops or repairers, as special tools must be used and
special gaskets must be fitted. Lifting units/lifting columns under warranty must
also be returned to authorised LINAK workshops.
Warning!
If any of the DESKLINE products are opened, there will be a risk of
subsequent malfunction.
Warning!
The DESKLINE®systems do not withstand to cutting oil.

7
Misc. on the DESKLINE®system
Warranty
There is a 36 months’ warranty on the DESKLINE products against manufacturing
faults from the production date of the individual products (see label).
LINAK A/S’ warranty is only valid in so far as the equipment has been used and
maintained correctly and has not been tampered with. Furthermore, the system
must not be exposed to violent treatment. In the event of this, the warranty will be
ineffective/invalid. For further details, please see LINAK A/S ordinary conditions of
sale.
Maintenance
Clean dust and dirt on the outside of the system, at appropriate intervals and
inspect them for damage and breaks.
Inspect the connections, cables and plugs and check for correct functioning as well
as fixing points.
The cleaners and disinfectants must not be highly alkaline or acidic
(pH value 6-8).

8
The DESKLINE®DL2 system contains following products:
1 or 2 DL2 lifting column(s) (no memory or parallel drive)
1 Control box CBD2
1 DP (Desk Panel)
1 Exchangeable mains cable
(With mains cut-off the cable is not exchangeable)
Options:
Built-in control box (CBD)
Class 1 protection (not if built-in CBD)
Prepared for 1 or 2 anti-squeeze safety switches
(NO type = normally open), only stop (not if built-in CBD)

9
Mounting guidelines for DL2 with CBD2N control box
The DL2 column is supplied with either 8 mm end plates or 3 mm end plates.
8 mm end plates:
For mounting on the desk frame there are 4 holes for M10 bolts. It is
recommended to use all 4 bolts.
3 mm end plates:
For mounting on the desk frame there are 4 holes in the column for DG 80 x 35
screws. It is recommended to use all 4 screws.
As the table top amplifies the sound we advise you to place a vibration/shock-
absorbing material between the table top and the table frame.
The outer profile of the DL2 column has tracks, which can be used for mounting a
bracket. The mounting bracket can be used for e.g.:
Mounting a customised cover (for encapsulation of the DL2).
Mounting of a computer
Figure 1
Example of how to mount a DL2 system

10
To limit the influence from the bending moment it is recommended to place the
heaviest load in the shaded area (see figure 2) in which the spindle is placed. The
spindle part is placed in the same side as the cable outlet.
See the DL2 data sheet for further information regarding bending moment.
Bending moment
Figure 2
LINAK recommends that the DESKLINE®system should be used in push
applications.
X-
X+
Y-
Y+
Spindle top

11
Mounting guidelines CBD2N
The CBD must not be packed in heat insulating material, but must be placed so
that it can emit waste heat into the surroundings. There are no ventilation holes to
consider, the CBD emits heat through the surface.
The plug must be visable when the CBD is mounted so that the supply to the CBD
can be disconnected at replacement, if any.
The mounting screws on the control box must be fastened with a max. torque of 1
Nm.
The mounting surface, to which the control box is attached, should have a surface
evenness of max. ± 0.5 mm.
For mounting and operation of the desk panel, please see the separate user
manual for desk panels.
CBD2N - Control box
The control box is to be fastened with 4 screws
with a head diameter between ø 8 and ø 10 mm.
Out of regard for the tension surface ø 10 mm is
preferable.
See drawing appendix for placing of mounting
holes and the space the CBD takes up.

12
Electrical connection of the DL2 system:
DESKLINE system with a CBD2N which is not built into the DL2:
The DESKLINE®system is to be connected as shown on figure 3. The DL2 is to be
connected to the socket on the control box by means of the motor cable,
which is supplied with an 8-pin plug. The connection of the DL2’s are on the
same side of the control box.
See figure 3.
Finally the mains cable is to be mounted and power switched on.
Please note that the control box must only be connected to the voltage
stated on the label.
Be careful that the plugs are fixed exactly above the counterpart before
pushing them together. Otherwise the plugs may bend and following errors
may occur:
The lifting units will not run as there is no current
The lifting units cannot find the end-stop positions
In the worst case the switches in the control box will short-circuit, which will
damage the CBD2.
The control (DP) is to be connected to port B on the control box - the
opposite side of the DL2 column (see figure 3).
The connection is made by a 8 pole modular jack plug.
Up to 2 SLS (Safety Limit Switches) can be connected to the control
box on the opposite side of the lifting units. The connection is made
by DC mini jack plugs (see figure 3).

13
Figure 4
DL2
DL2
mains
cable
(fixed)
Modular jack
for connection
of control
DP
8 pole plug
AB
DL2 cable
DL2 CBD2
CBD2N
SLS
Mains cable
DP
8 pole plug
DL2
cable
DESKLINE system with a built-in CBD2:
The DESKLINE®system is to be connected as shown on figure 15. The lifting unit
DL2 is equipped with an 8 pole female modular jack for connection of the
control. The DL2 is also equipped with a fixed mains cable.
Figure 3

14
Operation with SLS
The CBD2N supports two SLS (Safety Limit Switch) inputs. The switches must be
type NO (normally open). The SLS can optionally be connected to the SLS input.
Each SLS input controls one function. The function is stated by choice of CBD2N.
Below functions are possible:
1 input, CH1 down
2 input, CH1 and CH2 down
1 input, CH1 up
2 input, CH1 and CH2 up
2 input, CH1 up and down
2 input, CH1 down and CH2 up
When SLS is activated the movement will stop immediately. It will not be possible to
drive in the opposite direction until reactivating the control.
SLS (Safety Limit Switch)

15
Description of the DESKLINE®DL2 Memory System with CBD2
E/F/G
The DESKLINE®DL2 Memory system contains the following products:
1, 2 or 3 DL2 lifting column (s)
1 Control box CBD2
1 DP Desk Panel
1 DPA/DPB Desk Panel
1 Exchangeable mains cable
(With mains cut-off the cable is not exchangeable)
Options:
Built-in control box (CBD)
Class 1 protection (not if built-in CBD)
Prepared for 1 or 2 anti-squeeze safety switches
(NO type = normally open), only stop (not if built-in CBD)
It is possible to run extra actuators (LA31 with hall) (not if built-in CBD)
Description of the DESKLINE®DL2 system
Each Deskline lifting unit DL2 is equipped with a motor and memory drive is
ensured by means of software in the CBD2. CBD2 also has soft start, which ensures
a soft start when adjusting the desk.
Application of the DESKLINE®DL2 system:
Irrespective of the load the duty cycle 5% ~ 3 min./ hour or max. 1 min. at
continuous use stated in the data sheets, must NOT be exceeded as this will result
in a overheating of the motor, the brake and the spindle nut. Exceeding the duty
cycle will result in a dramatic reduction of the life of the system.

Figure 5
Example of how to mount a DL2 system
Mounting guidelines for DL2 System
The DL2 column is supplied with either 8 mm end plates or 3 mm end plates.
8 mm end plates:
For mounting on the desk frame there are 4 holes for M10 bolts. It is recom-
mended to use all 4 bolts.
3 mm end plates:
For mounting on the desk frame there are 4 holes in the column for DG 80 x 35
screws. It is recommended to use all 4 screws.
As the table top amplifies the sound we advise you to place a vibration/shock-
absorbing material between the table top and the table frame.
The outer profile of the DL2 column has tracks, which can be used for mounting a
bracket. The mounting bracket can be used for e.g.:
Mounting the control box.
Mounting an extra actuator for tilt function of the table top.
Mounting of a computer hard disc
Control box
DP1
16

To limit the influence from the bending moment it is recommended to place the
heaviest load in the shaded area (see figure 6) in which the spindle is placed. The
spindle part is placed in the same side as the cable outlet.
See data sheet for DL2 for further information regarding bending moment.
Bending moment
Figure 6
LINAK recommends that the DESKLINE®system should be used in push
applications.
X-
X+
Y-
Y+
Spindle top
17

18
The CBD must not be packed in heat insulating material, but must be placed so
that it can emit waste heat into the surroundings. There are no ventilation holes to
consider, the CBD emits heat through the surface.
The plug must be visable when the CBD is mounted so that the supply to the CBD
can be disconnected at replacement, if any.
The mounting screws on the control box must be fastened than a max. torque of 1
Nm.
The mounting surface, to which the control box is attached, should have a surface
evenness of max. ± 0.5 mm.
Mounting guidelines CBD2 E/F/G
CBD2 - Control box
The control box is to be fastened with 4 screws
with a head diameter between ø 8 and ø 10 mm.
Out of regard for the tension surface ø 10 mm is
preferable. See drawing appendix for placing of
mounting holes and the space the CBD takes up.

19
Electrical connection of the DL2 system:
DESKLINE system with a CBD which is not built into the DL2:
The DESKLINE®system is to be connected as shown on figure 10 and 11. The DL2
is to be connected to the socket on the control box by means of the motor
cable, which is supplied with an 8-pin plug. The connection of the DL2’s are on
the same side of the control box. See figure 10.
Be careful that the plugs are fixed exactly above the counterpart before
pushing them together. Otherwise the plugs may bend and following errors
may occur:
The lifting units will not run as there is no current
The lifting units start to run but stop due to lack of pulses
The lifting units cannot find the end-stop positions
The system cannot be initialised and therefore it cannot find its memory
positions.
In the worst case the switches in the control box will short-circuit, which will
damage the CBD2 (see figure 10).
The control (DP/DPA/DPB) is to be connected to port B on the control
box - the opposite side of the DL2 column (see figure 10). The
connection is made by means of a 6 or 8 pole modular jack plug. Up
to 2 SLS (Safety Limit Switches) can be connected to the control box
on the opposite site of the lifting units. The connection is made by
means of DC mini jack plugs (see figure 10).
Finally the mains cable is to be mounted and power switched on.
Please note that the control box must only be connected to the voltage
stated on the label.

20
Figure 11
DESKLINE system with a built-in CBD2:
The DESKLINE®system is to be connected as shown on figure 11. The lifting unit
DL2 is equipped with a 8 pole female modular jack for connection of the
control. The DL2 is also equipped with a fixed mains cable.
8 pole plug
DL2
DL2
fixed
mains
cable
Modular jack
for connection
of control
}
DPA
DP
Figure 10
DL2 CBD2
DL2 cable
DL2
cable
}
AB
DP
DPA SLS
Mains cable
CBD2
8 pole plug
Other manuals for DESKLINE DL2
1
Table of contents
Other Linak Lifting Column manuals

Linak
Linak DESKLINE DL18 IC User manual

Linak
Linak DL8 User manual

Linak
Linak DL16 User manual

Linak
Linak DESKLINE DL18 User manual

Linak
Linak DESKLINE DL1A User manual

Linak
Linak BL1 User manual

Linak
Linak DL8IC User manual

Linak
Linak DL15 User manual

Linak
Linak TECHLINE ELEVATE - LC3 IC User manual

Linak
Linak Deskline DL20 IC User manual

Linak
Linak DESKLINE DL1A User manual

Linak
Linak MEDLINE CARELINE Service readout User manual

Linak
Linak DL8IC User manual

Linak
Linak DESKLINE DL5 User manual

Linak
Linak DESKLINE DL4S User manual

Linak
Linak DESKLINE DL20 User manual

Linak
Linak DESKLINE DL5 IC User manual

Linak
Linak DESKLINE DL2 User manual

Linak
Linak CBD6S 200W User manual