LuCell AEGIS User manual


Safety Precautions
Safety precautions are to prevent any unexpected risk or damage.
Please read before use.
~ Be careful when opening and closing door. Finger or objects may get stuck.
~ Keep children away when operating the safe.
~ Do not hit edge of safe to avoid injury.
~ Safe is very heavy. Be careful when moving or installing safe to avoid injury.
~ Firmly fix safe to ground when installing. When moving safe, engage
professionals if needed.
~ Improper handling of safe can cause damage to floor.
~ Place safe on a flat surface. Otherwise, safe door may not close.
~ Avoid placing fragile objects, such as ceramic or glass, on safe.
They may fall and cause injury.
Before Use
•Product may malfunction if foreign metal substances or moisture enter keypad.
•Do not scratch keypad and fingerprint scanner with any sharp object.
•Do not apply excessive force on the keypad.
•Avoid exposure to any chemicals (gasoline, benzene, solvent, acetone, thinner, etc.)
•Avoid direct fire or heat.
•Remove batteries when safe is not in use for long periods.
•Excessive force to safe handle may cause breakage.
• Safe can be broken into by cutting or blazing tools. Our Company is not liable for
any stolen items.

Shelf
START button
Biometric (Fingerprint)
reader
Key
Handle
Battery case
Input panel
Drawer
MEMORY
button
Alarm
Keypad Overview
Keypad Lock Mode
InsideOutside
How to use Alarm 1. Use the ‘On/Off’ switch on the Alarm to activate/deactivate.
2. Use 1.5volt alkaline batteries (AAAx3).
Push START button
for 10 seconds
Push START button
for 3 seconds
Lock out mode activated.
Lock out mode deactivated.

Battery Replacement
Flip up Display Cover Insert four 1.5V new
Alkaline batteries.
Flip the Display Cover
Back and press tight.
Attention
Opening / Closing door
• After replacing batteries, confirm safe is working properly before closing door.
• Use 1.5Volt Alkaline batteries (AA x 4). (No lithium, rechargeable or heavy duty
batteries.)
•Press START button twice for security mode to hide password.
•Press START button to cancel password entry.
•Safe must be opened within 3 ~ 4 seconds.
•“Err-03” indicates incorrect password.
•5 consecutive incorrect password will sound alarm for 3 mintues.
•Press START button can enter correct password to stop the alarm.
The factory default password of this safe has been set as 1 2 3 4 5 6.
It is highly recommended to change.
Press START
button.
Press START
button again.
Turn handle and/
or key to open door.
Key in password.

Followed by
“ - - - - - - ”
Changing Password
Attention
Combination of 4 ~ 20 digit code can be used as a password
Safe can be programmed with up to 2 sets of passwords.
Press MEMORY button
located on the rear side of door.
“CodE” is on the
LCD display.
Enter new 4 ~ 20 digit
password and press
START button
Enter 4 ~ 20 digit
password again and press
START button
Your new password
is saved.
Volume Control
Make sure the door is open during this process.
Press MEMORY button
once.
Press MEMORY button
twice.
Press and hold
MEMORY button
for 3 seconds
Volume
setting of
Voice
Instruction Choose volume level
between 0 and 4.
Press START button
to finish.
Press START button
to finish.
Beep
on / off
Press and hold
MEMORY button
for 3 seconds
Choose 0 or 1.

Register fingerprints Maximum of 10 fingerprints
Attention
Make sure each new fingerprint works before closing the door.
Press and hold MEMORY
button for 3 seconds.
Press MEMORY
button once.
Press ‘ 0 ’
to register.
Position finger on the
biometric reader again.
Registered.
(LCD will show Fingerprint
Id number.)
Position finger on the
biometric reader.
Delete fingerprints
Attention
“no-Fr” will be displayed when no fingerprint was registered.
Press and hold MEMORY
button for 3 seconds.
Press MEMORY
button once.
Press ‘ 1 ’ to enter
dELEtE mode.
LCD will display
“dELEtE”.
Input Id number you want
to delete and press START button.
To delete all fingerprints at one go,
press MEMORY button once.
Fingerprint deleted.

Opening the safe
with fingerprint
- If no fingerprint was registered, the safe can only be opened by
the password.
- “Err-04” is shown when the finger is not positioned correctly on the
biometric reader, or an unauthorised fingerprint attempts access.
- Dirt, sweat, injuries, cuts, scars, or wound may cause “Err-04”
message to appear.
Bolt-Down Instructions
The solenoid
is dis-engaged.
Turn handle and/
or key to open door.
Press START
button.
Position finger on the
biometric reader.
- Anchor bolt should be fitted into floor BEFORE safe is placed over.
- Bolt may need to be cut.
- Cover is provided for fire resistant safe. Place cover over hole.
NOTE:
1. Please see drawing in the left. Anchor bolt
may vary according to model.
2. After checking the anchor bolt size ‘A’, drill
a hole with ‘B’ size into the concrete flooring
to a depth of 50mm (2inch).
3. Insert anchor bolt and pipe into the hole.
A (Anchor Size)
B (Diameter of hole)
M12 x 145L
O 19.6
4. Place flat washer and nut on anchor bolt and tighten (14mm wrench) to allow
anchor pipe to expand and secure into the floor.
5. Remove nut and washer from anchor bolt.
6. Place safe on to p pf anchor bolt through centre hole in bottom of safe.
7. Place washer, spring washer and nut on anchor bolt amd tighten.

Fingerprint module has problem
This message is shown when
the safe was forcefully opened
or there is a sensor problem
Fingerprint operation failure
Unregistered fingerprint
Keypad lock mode ON
Low battery
Button error
Keypad malfunction
Low battery
Exceeded time limit during
password change
Lock equipment error
Incorrect turning of handle/key
Incorrect password
5 times wrong password input
Circuit error
Keypad lock mode ON
No response when
START button pressed
“Err-03” message
appears
Does not open
when “OPEN”
is displayed
Cannot change
password
“Act” message appears
Forgot password
Display Error_Err-04
Display Error_Err-05
Display Error_Err-11
Display Error_Err-13
“Lo_bAt” message
appears
Alarm continues ringing
and safe does not work
Incorrect insertion of batteries
Dead batteries
Press START for 3 seconds to deactivate
keypad lock mode
Press START for 3 seconds to deactivate
keypad lock mode
Enter correct password or wait 3 mintues
unttl alarm stops
Enter correct password
Enter password within 5 seconds
Replace new Alkaline batteries
- Input the password
- if the message repeats,
contact Service Centre
Try the registered fingerprint again
Contact Service Centre
Contact Service Centre
Contact Service Centre
Contact Service Centre
Contact Service Centre
Contact Service Centre
Turn handle clockwise
Replace new Alkaline batteries
Confirm correct insertion of batteries
Replace new Alkaline batteries
Situation Possible Causes Measures
- Try again or register new,
clear fingerprint of another finger
- if the message repeats,
contact Service Centre
Table of contents
Other LuCell Safe manuals