M-system R3Y-SS8 User manual

R3Y-SS8
P. 1 / 3 EM-8958 Rev.3
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
the contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■ PACKAGE INCLUDES:
DC current input module ........................................... (1)
■ MODEL NO.
Check that model No. described on the specification label is
exactly what you ordered.
■ INSTRUCTION MANUAL
This manual describes necessary points of caution when you
use this product, including installation, connection and basic
maintenance procedures.
INSTRUCTION MANUAL
MODEL R3Y-SS8
DC CURRENT INPUT MODULE
(8 points, isolated)
POINTS OF CAUTION
■ CONFORMITY WITH EC DIRECTIVES
• The equipment must be mounted inside the instrument
panel of a metal enclosure.
• The actual installation environments such as panel con-
figurations, connected devices and connected wires may
affect the protection level of this unit when it is integrated in
a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure CE conformity.
■ HOT INSERTION/REMOVAL OF MODULES
Removing or replacing modules does not affect other modules
on the same backplane. It is possible to replace them without
removing the power supply. However, replacing multiple
modules at once may greatly change line voltage levels. We
recommend that you replace them one by one.
■ ENVIRONMENT
• Indoor use
• When heavy dust or metal particles are present in the air,
install the unit inside proper housing with sufficient ventila-
tion.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH in
order to ensure adequate life span and operation.
■ WIRING
• Do not install cables (power supply, input and output) close
to noise sources (relay drive cable, high frequency line, etc.).
• Do not bind these cables together with those in which noises
are present. Do not install them in the same duct.
■ UNUSED INPUT CHANNELS
Set the unused channels to -20 – +20mA or 0 – 20mA range.
Otherwise, set them as "Unused" with PC Configurator
software: R3CON. Unused channels left open with 4 – 20mA
setting are equal to the input lower than -15%, which sets a
data abnormality at the PLC or the host device.
■ AND ....
The unit is designed to function as soon as power is supplied,
however, a warm up for 10 minutes is required for satisfying
complete performance described in the data sheet.
INSTALLATION
Use the Installation Base (model: R3-BSx).
R3Y-SS8
P. 2 / 3 EM-8958 Rev.3
COMPONENT IDENTIFICATION
•Conversion Rate: SW3
SW CONVERSION RATE
160 ms (*)80 ms 40 ms 20 ms
SW3-1 OFF ON OFF ON
SW3-2 OFF OFF ON ON
(*) Factory setting
■ FRONT VIEW■ SIDE VIEW
RUN LED
ERR LED
Input Connector
• Pin Assignment
B
20 A
20
B
1A
1
SW2SW1
ON
1
2
3
4
5
6
7
8
ON
ON
1
2
3
4
5
6
7
8
SW3
1
2
3
4
Range
Input 1-4 (SW1)
or
Input 5-8 (SW2)
Conv.
Rate
■ DIMENSIONS mm (inch)
TERMINAL CONNECTIONS
Connect the unit as in the diagrams below and the next page.
130 (5.12)
27.5 (1.08) 110 (4.33) POSITIONING
GUIDE
■SIDE DIP SW
•Input Range: SW1, SW2 (selectable per 4 channels)
INPUT 1 through INPUT 4 (SW1)
INPUT 5 through INPUT 8 (SW2) RANGE
1234
OFF OFF OFF OFF
4 – 20mA
(*)
ON OFF OFF OFF 0 – 20mA
OFF ON OFF OFF
-20 – +20mA
■STATUS INDICATOR LED
RUN indicator: Bi-color (red/green) LED;
Red when the bus A operates normally;
Green when the bus B operates normally;
Amber when both buses operate normally.
ERR indicator: Bi-color (red/green) LED;
Red with the input circuit abnormality (AD
converter response failure);
Green in normal operating conditions.
R3Y-SS8
P. 3 / 3 EM-8958 Rev.3
M-SYSTEM WARRANTY
M-System warrants such new M-System product which it manufactures to be free from defects in materials and workmanship during the 36-month period following the date that such
productwasoriginallypurchasedifsuchproducthasbeenusedundernormaloperatingconditionsandproperlymaintained,M-System'ssoleliability,andpurchaser'sexclusiveremedies,
under this warranty are, at M-System's option, the repair, replacement or refund of the purchase price of any M-System product which is defective under the terms of this warranty. To
submit a claim under this warranty, the purchaser must return, at its expense, the defective M-System product to the below address together with a copy of its original sales invoice.
THIS IS THE ONLY WARRANTY APPLICABLE TO M-SYSTEM PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. M-SYSTEM SHALL HAVE NO LIABILITY FOR CONSEQUENTIAL, INCIDENTAL OR
SPECIAL DAMAGES OF ANY KIND WHATSOEVER.
M-System Co., Ltd., 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN, Phone: (06) 6659-8201, Fax: (06) 6659-8510, E-mail: [email protected]
INTERNAL POWER
BUS A
BUS B*
*For dual redundant communication.
BUS CONNECTOR
18B
9B
17B
13B
10B
6B
18A
5B
14A
17A
13A
10A
6A
5A
9A
–
INPUT 1 +
–
INPUT 2 +
–
INPUT 3 +
–
INPUT 4 +
–
INPUT 5 +
–
INPUT 6 +
–
INPUT 7 +
–
INPUT 8 +
14B
■ CONNECTION DIAGRAM ■ INPUT CONNECTOR (40-pin)
PIN NO. ASSIGNMENT PIN NO. ASSIGNMENT
1A NC 1B NC
2A NC 2B NC
3A NC 3B NC
4A NC 4B NC
5A – IN8 5B – IN4
6A + IN8 6B + IN4
7A NC 7B NC
8A NC 8B NC
9A – IN7 9B – IN3
10A + IN7 10B + IN3
11A NC 11B NC
12A NC 12B NC
13A – IN6 13B – IN2
14A + IN6 14B + IN2
15A NC 15B NC
16A NC 16B NC
17A – IN5 17B – IN1
18A + IN5 18B + IN1
19A NC 19B NC
20A NC 20B NC

Other M-system Control Unit manuals

M-system R30SV2 User manual

M-system

M-system R30SV2 User manual

M-system R7L-SV4-R User manual

M-system

M-system R7L-SV4-R User manual

M-system R7D-EC16B User manual

M-system

M-system R7D-EC16B User manual

M-system R3-SV8C User manual

M-system

M-system R3-SV8C User manual

M-system R3Y-SV8 User manual

M-system

M-system R3Y-SV8 User manual

M-system R3S-RR8 User manual

M-system

M-system R3S-RR8 User manual

M-system R7HL-DAC15E User manual

M-system

M-system R7HL-DAC15E User manual

M-system R7ML-YV2-R User manual

M-system

M-system R7ML-YV2-R User manual

M-system R7M-EC8B/UL User manual

M-system

M-system R7M-EC8B/UL User manual

M-system R30BS User manual

M-system

M-system R30BS User manual

M-system R7HL-TS4 User manual

M-system

M-system R7HL-TS4 User manual

M-system R8-SVT8 User manual

M-system

M-system R8-SVT8 User manual

M-system F2DL User manual

M-system

M-system F2DL User manual

M-system R7ML-EC8D User manual

M-system

M-system R7ML-EC8D User manual

M-system R7HL-YS2 User manual

M-system

M-system R7HL-YS2 User manual

M-system R7L-EC16B User manual

M-system

M-system R7L-EC16B User manual

M-system EtherCAT R30GECT1 User manual

M-system

M-system EtherCAT R30GECT1 User manual

M-system R7M-DC16B User manual

M-system

M-system R7M-DC16B User manual

M-system R3Y-SS8N User manual

M-system

M-system R3Y-SS8N User manual

M-system R3-PT4 User manual

M-system

M-system R3-PT4 User manual

M-system R8-NC3 User manual

M-system

M-system R8-NC3 User manual

M-system R7D-DA16 User manual

M-system

M-system R7D-DA16 User manual

M-system R7HL-DC8C User manual

M-system

M-system R7HL-DC8C User manual

M-system LONWORKS R3-NL2 User manual

M-system

M-system LONWORKS R3-NL2 User manual

Popular Control Unit manuals by other brands

Technibel CMHGV 2101 installation instructions

Technibel

Technibel CMHGV 2101 installation instructions

Vimar Eikon 20541 manual

Vimar

Vimar Eikon 20541 manual

CommScope Teletilt ATC200-LITE-USB instruction sheet

CommScope

CommScope Teletilt ATC200-LITE-USB instruction sheet

Pfeiffer Vacuum TPG 366 MAXIGAUGE operating instructions

Pfeiffer Vacuum

Pfeiffer Vacuum TPG 366 MAXIGAUGE operating instructions

Satel VIVER manual

Satel

Satel VIVER manual

Emerson KEYSTONE OPTISEAL F16 Installation and maintenance instructions

Emerson

Emerson KEYSTONE OPTISEAL F16 Installation and maintenance instructions

LOVATO ELECTRIC RGK800 installation manual

LOVATO ELECTRIC

LOVATO ELECTRIC RGK800 installation manual

Parker 810 Series Installation, operating,  & maintenance instructions

Parker

Parker 810 Series Installation, operating, & maintenance instructions

Supermicro AOC-ATG-i2T2SM user guide

Supermicro

Supermicro AOC-ATG-i2T2SM user guide

Zurn Wilkins ZW204 Installation, Troubleshooting, Maintenance Instructions

Zurn Wilkins

Zurn Wilkins ZW204 Installation, Troubleshooting, Maintenance Instructions

Continental Hydraulics CEM-SD-A installation manual

Continental Hydraulics

Continental Hydraulics CEM-SD-A installation manual

Wincor Nixdorf CCDM Service manual

Wincor Nixdorf

Wincor Nixdorf CCDM Service manual

MD mXion KBM user manual

MD

MD mXion KBM user manual

3Com SuperStack II 3C81665 Quick reference guide

3Com

3Com SuperStack II 3C81665 Quick reference guide

Infosystem Technology Corporation WM-110 user manual

Infosystem Technology Corporation

Infosystem Technology Corporation WM-110 user manual

Avnet Reach Further MT3620 Datasheet and User Manual

Avnet

Avnet Reach Further MT3620 Datasheet and User Manual

Cab Technology PX Series Service manual

Cab Technology

Cab Technology PX Series Service manual

H3C PSR250-12A user manual

H3C

H3C PSR250-12A user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.