TC101A
Thermocouple-Based Temperature
Data Logger
PRODUCT
USER GUIDE
To view the full MadgeTech product line, visit
our website at madgetech.com.
TABLE OF CONTENTS
2Product Overview
2Installation Guide
2Wiring the Data Logger
2Device Operation
4Device Maintenance
4Need Help?
Product User Guide | 2
TC101A
PRODUCT USER GUIDE
Product Overview
The TC101A temperature data logger, is a compact
versatile device to be used with thermocouple probes for
accurate temperature monitoring and profiling.
Compatible with eight different types of thermocouple
probes, the TC101A can measure temperatures as low
as -270 °C (-454 °F), and up to as high as 1820 °C (3308 °F)
(probe dependent), with an environmental operating
temperature range of -40 °C to +80 °C (-40 °F to +176 °F) for
the data logger body.
Installation Guide
Installing the Interface Cable
IFC200 (sold separately) — Insert the device into a USB
port. The drivers will install automatically.
Installing the Software
The Software can be downloaded from the MadgeTech
website at madgetech.com. Follow the instructions
provided in the Installation Wizard. Compatible with
Standard Software version 2.03.06 or later and Secure
Software version 4.1.3.0 or later.
Wiring the Data Logger
MP Model Wiring
The standard connector is the SMP connection which
allows for the user to insert a subminiature thermocouple
plug into the connector on the device.
ST and TB Model
WiringThe TC101A-ST and TC101A-TB have a three
position removable screw terminal. This enables the data
logger to be connected to most 3-wire thermocouples
with lead wires. Note: Be sure to connect the thermocouple
with the right polarity as marked on the device case.
The TC101A-ST and TC101A-TB have the ability to shield the
thermocouple with the ground connection. When using a
2-wire thermocouple, leave the ground input unconnected.
Device Operation
Connecting and Starting the Data Logger
1. Once the software is installed and running, plug the
interface cable into the data logger.
2. Connect the USB end of the interface cable into an
open USB port on the computer.
3. The device will appear in the Connected Devices list.
Highlight the desired data logger.
4. For most applications, select Custom Start from
the menu bar and choose the desired start method,
reading rate and other parameters appropriate for the
data logging application and click Start.
• Quick Start applies the most recent custom start
options
• Batch Start is used for managing multiple loggers
at once
• Real Time Start stores the dataset as it records
while connected to the logger
5. The status of the device will change to Running,
Waiting to Start or Waiting to Manual Start,
depending upon your start method.
6. Disconnect the data logger from the interface cable
and place it in the environment to measure.
Note: The device will stop recording data when the end of memory
is reached or the device is stopped. At this point the device cannot be
restarted until it has been re-armed by the computer.
Product User Guide | 3
TC101A
PRODUCT USER GUIDE
Trigger Settings
The device can be programmed to only record based off
user configured trigger settings.
1. In the Connected Devices panel, click the device
desired.
2. On the Device Tab, in the Information Group, click
Properties. Users can also right-click the device and
select Properties in the context menu.
3. Select Trigger Settings from the Device Menu: Start
Device or Identify Device and Read Status.
Note: Trigger formats are available in Window and Two Point (bi-level)
mode. Window allows for one range of temperature monitoring and two
point mode allows for two ranges of temperature monitoring.
Set Password
To password protect the device so that others cannot
start, stop or reset the device:
1. In the Connected Devices panel, click the device desired.
2. On the Device Tab, in the Information Group, click
Properties. Or, right-click the device and select
Properties in the context menu.
3. On the General Tab, click Set Password.
4. Enter and confirm the password in the box that
appears, then select OK.
LED Indicators
Green LED blinks: 10 seconds to indicate
logging and 15 seconds to indicate delay
start mode.
Red LED blinks: 10 seconds to indicate
low battery and/or memory and 1 second
to indicate an alarm condition.
Multiple Start/Stop Mode Activation
• To start device: Press and hold the pushbutton for
5 seconds, the green LED will flash during this time. The
device has started logging.
• To stop the device: Press and hold the pushbutton for
5 seconds, the red LED will flash during the this time.
The device has stopped logging.
Downloading Data from a Data Logger
1. Connect the logger to the interface cable.
2. Highlight the data logger in the Connected Devices list.
Click Stop on the menu bar.
3. Once the data logger is stopped, with the logger
highlighted, click Download. You will be prompted to
name your report.
4. Downloading will offload and save all the recorded
data to the PC.
Thermocouple Type
To change the thermocouple type:
• In the Connected Devices panel, click the device desired.
• On the Device Tab, in the Information Group, click
Properties. Or, right-click the device and select
Properties in the context menu.
• On the General Tab, change the Thermocouple type in
the drop down menu.
• Apply these changes, there will be a prompt to reset the
device, select yes.
Alarm Settings
To change the settings for the alarm:
1. Select Alarm Settings from the Device Menu in the
MadgeTech Software. A window will appear allowing to
set the high and low alarms and warning alarms.
2. Press Change to edit the values.
3. Check Enable Alarm Settings to enable the feature
and check each high and low, warn and alarm box
to activate it. The values can be entered in the field
manually or by using the scroll bars.
4. Click Save to save the changes. To clear an active
alarm or warn, press the Clear Alarm or Clear Warn
button.
5. To set an alarm delay, enter the duration of time into
the Alarm Delay box in which the readings can be
outside of the alarm parameters.
PRODUCT USER GUIDE
TC101A
DOC-1218035-00 | REV 19 2020.05.22
NEED HELP?
6 Warner Road, Warner, NH 03278
(603) 456-2011
info@madgetech.com
madgetech.com
Product Support & Troubleshooting:
• Visit our Resources online at madgetech.com/resources.
• Contact our friendly Customer Support Team at (603) 456-2011 or support@madgetech.com.
MadgeTech 4 Software Support:
• Refer to the built-in help section of the MadgeTech 4 Software.
• Download the MadgeTech 4 Software Manual at madgetech.com.
• Contact our friendly Customer Support Team at (603) 456-2011 or support@madgetech.com.
Device Maintenance
Battery Replacement
Materials: Small Phillips Head Screwdriver and a
Replacement Battery (LTC-7PN)
1. Puncture the center of the back label with the screw
driver and unscrew the enclosure.
2. Remove the battery by pulling it perpendicular to the
circuit board.
3. Insert the new battery into the terminals and verify it
is secure.
4. Screw the enclosure back together securely.
Note: Be sure not to over tighten the screws or strip the threads.
Recalibration
Recalibration is recommended annually. To send devices
back for calibration, visit madgetech.com.

This manual suits for next models

2

Other MadgeTech Data Logger manuals

MadgeTech Shock101-5 User manual

MadgeTech

MadgeTech Shock101-5 User manual

MadgeTech HiTemp150-TSK User manual

MadgeTech

MadgeTech HiTemp150-TSK User manual

MadgeTech Process101A User manual

MadgeTech

MadgeTech Process101A User manual

MadgeTech TSR101 Series User manual

MadgeTech

MadgeTech TSR101 Series User manual

MadgeTech QuadRTD User manual

MadgeTech

MadgeTech QuadRTD User manual

MadgeTech HiTemp140 Series Specification sheet

MadgeTech

MadgeTech HiTemp140 Series Specification sheet

MadgeTech Titan S8 Specification sheet

MadgeTech

MadgeTech Titan S8 Specification sheet

MadgeTech RFPulse2000A User manual

MadgeTech

MadgeTech RFPulse2000A User manual

MadgeTech State101A Specification sheet

MadgeTech

MadgeTech State101A Specification sheet

MadgeTech X Series Specification sheet

MadgeTech

MadgeTech X Series Specification sheet

MadgeTech Volt101A-2.5V Specification sheet

MadgeTech

MadgeTech Volt101A-2.5V Specification sheet

MadgeTech HiTemp140-FP Specification sheet

MadgeTech

MadgeTech HiTemp140-FP Specification sheet

MadgeTech SciTemp140-PT Specification sheet

MadgeTech

MadgeTech SciTemp140-PT Specification sheet

MadgeTech Temp1000P User manual

MadgeTech

MadgeTech Temp1000P User manual

MadgeTech 902003-00 Specification sheet

MadgeTech

MadgeTech 902003-00 Specification sheet

MadgeTech PR2000 User manual

MadgeTech

MadgeTech PR2000 User manual

MadgeTech RHTemp2000 User manual

MadgeTech

MadgeTech RHTemp2000 User manual

MadgeTech Titan S8 Specification sheet

MadgeTech

MadgeTech Titan S8 Specification sheet

MadgeTech HiTemp140-FP User manual

MadgeTech

MadgeTech HiTemp140-FP User manual

MadgeTech HiTemp1400 User manual

MadgeTech

MadgeTech HiTemp1400 User manual

MadgeTech RTDTemp2000 User manual

MadgeTech

MadgeTech RTDTemp2000 User manual

MadgeTech X Series Specification sheet

MadgeTech

MadgeTech X Series Specification sheet

MadgeTech Volt101A User manual

MadgeTech

MadgeTech Volt101A User manual

MadgeTech 902152-00 Specification sheet

MadgeTech

MadgeTech 902152-00 Specification sheet

Popular Data Logger manuals by other brands

Gemini Tinyview TV-0020 manual

Gemini

Gemini Tinyview TV-0020 manual

Steren 300-505 quick start guide

Steren

Steren 300-505 quick start guide

Triplett EMDL700 manual

Triplett

Triplett EMDL700 manual

wireless Seismic RT System 2 Deployment guide

wireless Seismic

wireless Seismic RT System 2 Deployment guide

METER ZL6 Replacement manual

METER

METER ZL6 Replacement manual

Huawei SmartLogger3000 Configuration guide

Huawei

Huawei SmartLogger3000 Configuration guide

Steinberg Systems SBS-DL-10 user manual

Steinberg Systems

Steinberg Systems SBS-DL-10 user manual

Extech Instruments SD910 user manual

Extech Instruments

Extech Instruments SD910 user manual

Star-Oddi DST microRF-HRT user manual

Star-Oddi

Star-Oddi DST microRF-HRT user manual

Ocea Soft Emerald user guide

Ocea Soft

Ocea Soft Emerald user guide

Intempco CX600 manual

Intempco

Intempco CX600 manual

Intech Instruments Ltd HR Series Replacement

Intech Instruments Ltd

Intech Instruments Ltd HR Series Replacement

R/Evolution AXE110P manual

R/Evolution

R/Evolution AXE110P manual

Co2meter iSense Oxygen user manual

Co2meter

Co2meter iSense Oxygen user manual

SignalFire RANGER Wall Mount manual

SignalFire

SignalFire RANGER Wall Mount manual

Duncan Solutions AutoCITE X3 Series Training Reference

Duncan Solutions

Duncan Solutions AutoCITE X3 Series Training Reference

Addi-Data MSX-ilog Series Technical description

Addi-Data

Addi-Data MSX-ilog Series Technical description

METER ZL6 quick start

METER

METER ZL6 quick start

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.