MadgeTech HiTemp140-PT User manual

HiTemp140-PT
High Temperature Data Logger with
Bendable Stainless Steel Probe
IFC406 (Sold Separately)
IFC400 (Sold Separately)
PRODUCT
USER GUIDE
To view the full MadgeTech product line, visit
our website at madgetech.com.
Product User Guide | 2
HiTemp140-PT
PRODUCT USER GUIDE
Product Overview
The HiTemp140-PT is a submersible, temperature data
logger that can operate from -40 °C (-40 °F) up to +140 °C
(+284 °F) and has an accuracy of +/-0.1 °C (0.18 °F). The
device features a 12 or 24 inch bendable stainless steel
probe for measuring extended temperatures up to 350 °C
(662 °F). The probe is durable and can be spiraled, bent or
angled in any direction, making it easy to log temperatures
within bottles, vials or other hard to reach places.
Water Resistance
The HiTemp140-PT is fully submersible and is rated IP68. It
can be placed in environments with up to 230 feet (70 m)
of water.
Bend Radius
The flexible probe on the HiTemp140-PT can be bent to
a 0.25 inch bend radius. The probe should not be bent
within 1 inch of either weld joint.
Installation Guide
Installing the Software
The Software can be downloaded from the MadgeTech
website at madgetech.com. Follow the instructions
provided in the Installation Wizard.
Installing the Docking Station
IFC400 or IFC406 (sold separately) — Connect the device
into a USB port with the interface cable and install the
drivers.
Ordering Information
• 900230-00 — HiTemp140-PT-1 (1 inch piercing tip)
• 902152-00 — HiTemp140-PT-1-KR (key ring end cap)
• 900243-00 — HiTemp140-PT-5 (5 inch piercing tip)
• 902365-00 — HiTemp140-PT-5-KR (key ring end cap)
• 900306-00 — HiTemp140-PT-12 (12 inch piercing with
1 inch probe tip)
• 900319-00 — IFC400
• 900325-00 — IFC406
• 900097-00 — ER14250MR-145
Device Operation
Connecting and Starting the Data Logger
1. Once the software is installed and running, plug the
interface cable into the docking station.
2. Connect the USB end of the interface cable into an
open USB port on the computer.
3. Place the data logger into the docking station.
4. The data logger will automatically appear under
Connected Devices within the software.
5. For most applications, select Custom Start from
the menu bar and choose the desired start method,
reading rate and other parameters appropriate for the
data logging application and click Start. (Quick Start
applies the most recent custom start options, Batch
Start is used for managing multiple loggers at once,
Real Time Start stores the dataset as it records while
connected to the logger.)
6. The status of the device will change to Running or
Waiting to Start, depending upon your start method.
7. Disconnect the data logger from the interface cable
and place it in the environment to measure.
Note: The device will stop recording data when the end of memory
is reached or the device is stopped. At this point the device cannot be
restarted until it has been re-armed by the computer.
Downloading Data from a Data Logger
1. Place the logger into the docking station.
2. Highlight the data logger in the Connected Devices
list. Click Stop on the menu bar.
3. Once the data logger is stopped, with the logger
highlighted, click Download.
4. Downloading will offload and save all the recorded
data to the PC.
Product User Guide | 3
HiTemp140-PT
PRODUCT USER GUIDE
Device Operation (cont’d)
Trigger Settings
The device can be programmed to only record based off
user configured trigger settings.
1. In the Connected Devices panel, click the device desired.
2. On the Device Tab, in the Information Group, click
Properties. Or, right-click the device and select
Properties in the context menu.
3. Select Trigger in the Properties window.
4. Trigger formats are available in Window or Two Point
Mode. Window mode allows a high and/or low trigger set
point, and a trigger sample count or “window” of time
recorded when set points are exceeded to be defined. Two
point allows for different Start and Stop setpoints to be
defined for both the high and low triggers.
Refer to the Trigger Settings - MadgeTech 4 Data Logger
Software video on madgetech.com for instructions on
how to configure Trigger Settings.
Set Password
To password protect the device so that others cannot
start, stop or reset the device:
1. In the Connected Devices panel, click the device desired.
2. On the Device Tab, in the Information Group, click
Properties. Or, right-click the device and select
Properties in the context menu.
3. On the General Tab, click Set Password.
4. Enter and confirm the password in the box that
appears, then select OK.
Device Maintenance
O-Rings
O-ring maintenance is a key factor when properly
caring for the HiTemp140-PT. The O-rings ensure a tight
seal and prevent liquid from entering the inside of the
device. Please refer to the application note O-Rings 101:
Protecting Your Data, found at madgetech.com, for
information on how to prevent O-ring failure.
Battery Replacement
Materials: ER14250MR-145 Battery
1. Unscrew the bottom of the logger and remove the
battery.
2. Place the new battery into the logger. Note the polarity
of the battery. It is important to insert the battery with
positive polarity pointing upward towards the probe.
Failure to do so could result in product inoperability or
potential explosion if exposed to high temperatures.
3. Screw the cover back onto the logger.
Recalibration
MadgeTech recommends annual recalibration. To send
devices back for calibration, visit madgetech.com.
Note: This product is rated for use up to 140 °C (284 °F). Please heed the battery warning. The product will explode
if exposed to temperatures above 140 °C (284 °F).
HiTemp140-PT
NEED HELP?
DOC-1236035-00 | REV 7 2021.07.13
6 Warner Road, Warner, NH 03278
(603) 456-2011
info@madgetech.com
madgetech.com
Product Support & Troubleshooting
• Visit our Resources online at madgetech.com/resources.
• Contact our friendly Customer Support Team at (603) 456-2011 or support@madgetech.com.
MadgeTech 4 Software Support
• Refer to the built-in help section of the MadgeTech 4 Software.
• Download the MadgeTech 4 Software Manual at madgetech.com.
• Contact our friendly Customer Support Team at (603) 456-2011 or support@madgetech.com.

Other MadgeTech Data Logger manuals

MadgeTech TC101A User manual

MadgeTech

MadgeTech TC101A User manual

MadgeTech pHTemp101 User manual

MadgeTech

MadgeTech pHTemp101 User manual

MadgeTech pHTemp2000 User manual

MadgeTech

MadgeTech pHTemp2000 User manual

MadgeTech Therm-A-lert Specification sheet

MadgeTech

MadgeTech Therm-A-lert Specification sheet

MadgeTech Shock101-5 User manual

MadgeTech

MadgeTech Shock101-5 User manual

MadgeTech Bridge101A-150 User manual

MadgeTech

MadgeTech Bridge101A-150 User manual

MadgeTech PR1000IS Series Specification sheet

MadgeTech

MadgeTech PR1000IS Series Specification sheet

MadgeTech Temp101A User manual

MadgeTech

MadgeTech Temp101A User manual

MadgeTech PR140 Specification sheet

MadgeTech

MadgeTech PR140 Specification sheet

MadgeTech PR1000EX-30A Specification sheet

MadgeTech

MadgeTech PR1000EX-30A Specification sheet

MadgeTech X Series Specification sheet

MadgeTech

MadgeTech X Series Specification sheet

MadgeTech CurrentX Series Specification sheet

MadgeTech

MadgeTech CurrentX Series Specification sheet

MadgeTech PR2009 Specification sheet

MadgeTech

MadgeTech PR2009 Specification sheet

MadgeTech MadgeNet RFRHTemp2000A Specification sheet

MadgeTech

MadgeTech MadgeNet RFRHTemp2000A Specification sheet

MadgeTech SciTemp140-PT Specification sheet

MadgeTech

MadgeTech SciTemp140-PT Specification sheet

MadgeTech Temp1000P User manual

MadgeTech

MadgeTech Temp1000P User manual

MadgeTech QuadRTD User manual

MadgeTech

MadgeTech QuadRTD User manual

MadgeTech HiTemp150FP-TSK User manual

MadgeTech

MadgeTech HiTemp150FP-TSK User manual

MadgeTech RFCO2RHTemp2000A Specification sheet

MadgeTech

MadgeTech RFCO2RHTemp2000A Specification sheet

MadgeTech HiTemp140-PT Series Specification sheet

MadgeTech

MadgeTech HiTemp140-PT Series Specification sheet

MadgeTech Bridge101A User manual

MadgeTech

MadgeTech Bridge101A User manual

MadgeTech RTDTemp2000 User manual

MadgeTech

MadgeTech RTDTemp2000 User manual

MadgeTech Temp1000S User manual

MadgeTech

MadgeTech Temp1000S User manual

MadgeTech Titan S8 Specification sheet

MadgeTech

MadgeTech Titan S8 Specification sheet

Popular Data Logger manuals by other brands

CMA Dishmachines WILAB 002 user guide

CMA Dishmachines

CMA Dishmachines WILAB 002 user guide

Agrowtek SXW instruction manual

Agrowtek

Agrowtek SXW instruction manual

Locus Energy LGate 120 installation guide

Locus Energy

Locus Energy LGate 120 installation guide

NexSens Technology CB-450 user guide

NexSens Technology

NexSens Technology CB-450 user guide

Escort iMiniPlus user manual

Escort

Escort iMiniPlus user manual

Zico ZI-9530 manual

Zico

Zico ZI-9530 manual

Speedata KT40Q Faq

Speedata

Speedata KT40Q Faq

bmcm USB-AD16f manual

bmcm

bmcm USB-AD16f manual

Campbell CRVW3 product manual

Campbell

Campbell CRVW3 product manual

Racelogic VBOX HD Lite user guide

Racelogic

Racelogic VBOX HD Lite user guide

Furuno VR-3000 installation manual

Furuno

Furuno VR-3000 installation manual

berlinger Fridge-tag 3 manual

berlinger

berlinger Fridge-tag 3 manual

Consilium VDR F2 user guide

Consilium

Consilium VDR F2 user guide

MSR BudgetLine MSR63 manual

MSR

MSR BudgetLine MSR63 manual

PCE Instruments PCE-AQD 10-ICA user manual

PCE Instruments

PCE Instruments PCE-AQD 10-ICA user manual

Jetter JCM-501-E00 user manual

Jetter

Jetter JCM-501-E00 user manual

PMI Vision user manual

PMI

PMI Vision user manual

Praxisdienst LOG200 manual

Praxisdienst

Praxisdienst LOG200 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.