manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. MadgeTech
  6. •
  7. Data Logger
  8. •
  9. MadgeTech QuadVolt User manual

MadgeTech QuadVolt User manual

Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
To view the full MadgeTech product line,
visit our website at www.madgetech.com.
Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
Battery Warning
WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE,
FORCE OVER DISCHARGE, DISASSEMBLE, CRUSH, PENETRATE OR INCINERATE. BATTERY MAY
LEAK OR EXPLODE IF HEATED ABOVE 60°C (140°F).
Specifications subject to change.
See MadgeTech’s terms and conditions at www.madgetech.com
MadgeTech, Inc.
PO Box 50 lWarner, NH 03278
Phone 603.456.2011 lFax 603.456.2012
www.madgetech.com l[email protected]
DOC-1037035-00 REV 7 2012.02.16
QuadVolt and OctVolt
QuadVolt-100mV
4-channel +100mV Low Level
DCVoltage Data Logger
OctVolt-100mV
8-channel +100mV Low Level DC
Voltage Data Logger
QuadVolt-2.5V
4-channel 2.5V Low Level DC Voltage
Data Logger
QuadVolt-15V
4-channel 15V Low Level DC Voltage
Data Logger
QuadVolt-30V
4-channel 30V Low Level DC Voltage
Data Logger
OctVolt-2.5V
8-channel 2.5V Low Level DC Voltage
Data Logger
OctVolt-15V
8-channel 15V Low Level DC Voltage
Data Logger
OctVolt-30V
8-channel 30V Low Level DC Voltage
Data Logger
Part Number QuadVolt OctVolt
Voltage Rage
*See Table BelowVoltage Resolution
Voltage Accuracy
Memory 32,767/channel 16,383/channel
Sample Rate 1 second up to 12 hours
LED Indicator None
Channels 4 8
Required Interface Package IFC110 or IFC200
Baud Rate 2,400
Typical Battery Life 1 year
Operating Environment –40 to +60°C, 0 to 95%RH (non–condensing)
Material Anodized aluminum
Dimensions 3.5” x 4.4” x 1.0”
(89mm x 112mm x 26mm)
3.5” x 4.4” x 1.5”
(89mm x 112mm x 39mm)
Approvals CE - 100mV only
Nominal Range +100mV 0 to 2.5V 0 to 15V 0 to 30V
Measurement Range (VDC) +150mV -0.25 to 2.75 -1 to 16 -2 to 32
Accuracy +0.01%FSR +0.01%FSR +0.10%FSR +0.10%FSR
Resolution (mV) 5µV 0.1 0.5 1.0
Common Mode Input Range 0 to 2.5V 0 to 2.5V 0 to 2.5V 0 to 2.5V
*QuadVolt & OctVolt Range, Resolution and Calibrated Accuracy
Product Information Card
Wiring the Data Logger
QuadVolt and OctVolt Single Ended Wiring (2.5, 15 and 30V)
Two-position removable screw terminal connections; accepts 2-wire configurations.
QuadVolt and OctVolt Differential Wiring (+100mV)
Three-position removable screw terminal connections; accepts 3-wire configurations.
Warning: Note the polarity instructions. Do not attach wires to the wrong terminals.
Product Notes
Engineering Units
Engineering units are used to convert one measurement reading to another. The
MadgeTech software allows for software level Engineering Units (conversion applied to
data after download). Certain devices have device level Engineering Units, which upon
download automatically appear in the chosen unit of measure.
Please refer to the application note “Engineering Units” and Technical Support Videos,
found on the MadgeTech website, for information on how to manage Engineering Units.
Also view the Engineering Units Video for step-by-step setup instructions.
Device Operation
Starting the data logger
- Click Device Menu then Start Device.
- Choose the desired start method.
- Choose the start parameters by selecting a Reading Rate suitable for your application.
- Enter in any other desired parameters and click Start.
- A box will appear stating the data logger has been started. Click OK.
- Disconnect the data logger from the interface cable and place it in the environment to
measure.
Note: The device will stop recording data when the end of memory is reached or the device is stopped. At this point the device
cannot be restarted until it has been re-armed by the computer.
Downloading data from a data logger
- Connect the data logger to the interface cable.
- Click the Device Menu then Read Device Data. This will offload all recorded data onto
the PC.
Product Quick Reference Card
QuadVolt and OctVolt
Installation Guide
Installing the Interface cable
- IFC200
Insert the device into a USB port. The drivers will install automatically.
- IFC110
Plug the serial cable into the port and verify it is secure.
Installing the software
Insert the Software CD in the CD-ROM Drive. If the autorun does not appear, locate the
drive on the computer and double click on Autorun.exe. Follow the instructions provided
in the Wizard.
Connecting the data logger
- Once the software is installed and running, plug the interface cable into the data logger.
- Click the Communication Menu, then Auto Configure Port.
- After a moment, a box will appear stating a device has been found.
- Click OK. The Device Status box will appear. Click OK.
- At this point, communications have been configured for your logger. These settings can
be found under the Communication Menu.
Note: For additional installation instructions refer to your “Data Logger & Software Operating Manual”.
Device Maintenance
Battery Replacement
Materials: 3/32” HEX Driver (Allen Key) and Replacement Battery (U9VL-J)
- Remove the cover from the device by unscrewing the four screws.
- Remove the battery from its compartment and unsnap it from the connector.
- Snap the new battery into the terminals and verify it is secure.
- Replace the cover taking care not to pinch the wires. Screw the enclosure back together
securely.
Note: Be sure not to over tighten the screws or strip the threads.
Recalibration
The QuadVolt or OctVolt standard calibration is dependant upon the range.
Pricing: QuadVolt OctVolt
Recalibration traceable to NIST $69.00 $81.00
Recalibration $49.00 $61.00
Additional Services:
As Found Data $15.00 per parameter/channel
Verification Point $15.00 per point
Prices and specifications subject to change. See MadgeTech’s terms and conditions at www.madgetech.com
To send the devices back, visit www.madgetech.com, select Services then RMA Process.
Connector for interface cable
+ Input
- Input
Range 2.5V
15V
30V
Calibration
Point
0mV and
90-100mV
0mV and
2.25-2.5V
0mV and
27-30V

This manual suits for next models

1

Other MadgeTech Data Logger manuals

MadgeTech UltraShock-EB-5 User manual

MadgeTech

MadgeTech UltraShock-EB-5 User manual

MadgeTech ThermoVault Max Specification sheet

MadgeTech

MadgeTech ThermoVault Max Specification sheet

MadgeTech EggTemp-RH User manual

MadgeTech

MadgeTech EggTemp-RH User manual

MadgeTech X Series Specification sheet

MadgeTech

MadgeTech X Series Specification sheet

MadgeTech octtemp 2000 User manual

MadgeTech

MadgeTech octtemp 2000 User manual

MadgeTech HiTemp150-TSK User manual

MadgeTech

MadgeTech HiTemp150-TSK User manual

MadgeTech RHTemp2000 User manual

MadgeTech

MadgeTech RHTemp2000 User manual

MadgeTech EggTemp-RH User manual

MadgeTech

MadgeTech EggTemp-RH User manual

MadgeTech LynxPro User manual

MadgeTech

MadgeTech LynxPro User manual

MadgeTech PR2009 Specification sheet

MadgeTech

MadgeTech PR2009 Specification sheet

MadgeTech PRTrans1000IS Series Specification sheet

MadgeTech

MadgeTech PRTrans1000IS Series Specification sheet

MadgeTech QuadTemp2000 User manual

MadgeTech

MadgeTech QuadTemp2000 User manual

MadgeTech pHTemp2000 User manual

MadgeTech

MadgeTech pHTemp2000 User manual

MadgeTech HiTemp140-PT Specification sheet

MadgeTech

MadgeTech HiTemp140-PT Specification sheet

MadgeTech Process101A User manual

MadgeTech

MadgeTech Process101A User manual

MadgeTech Level2000 User manual

MadgeTech

MadgeTech Level2000 User manual

MadgeTech TempRetriever User manual

MadgeTech

MadgeTech TempRetriever User manual

MadgeTech Process101A User manual

MadgeTech

MadgeTech Process101A User manual

MadgeTech Bridge101A User manual

MadgeTech

MadgeTech Bridge101A User manual

MadgeTech Pulse101A User manual

MadgeTech

MadgeTech Pulse101A User manual

MadgeTech OctVolt Specification sheet

MadgeTech

MadgeTech OctVolt Specification sheet

MadgeTech RHTEMP1000EX Specification sheet

MadgeTech

MadgeTech RHTEMP1000EX Specification sheet

MadgeTech RFPulse2000A User manual

MadgeTech

MadgeTech RFPulse2000A User manual

MadgeTech MadgeNet RFRHTemp2000A Specification sheet

MadgeTech

MadgeTech MadgeNet RFRHTemp2000A Specification sheet

Popular Data Logger manuals by other brands

Danelec DM100-2014 Operator's manual

Danelec

Danelec DM100-2014 Operator's manual

Omega OM-USB-2404-UI user guide

Omega

Omega OM-USB-2404-UI user guide

PCE Instruments PCE-HT 71N user guide

PCE Instruments

PCE Instruments PCE-HT 71N user guide

Steren 300-500 quick start guide

Steren

Steren 300-500 quick start guide

Arexx TL-300 manual

Arexx

Arexx TL-300 manual

Keithley KUSB-3116 Getting started manual

Keithley

Keithley KUSB-3116 Getting started manual

Fluke 1738/B user manual

Fluke

Fluke 1738/B user manual

SOLIS W4G Quick installation manual

SOLIS

SOLIS W4G Quick installation manual

Microtronics myDatalogEx user manual

Microtronics

Microtronics myDatalogEx user manual

T&D TR7 Series user manual

T&D

T&D TR7 Series user manual

EIJKELKAMP CBR user manual

EIJKELKAMP

EIJKELKAMP CBR user manual

Grosvenor IT31 user guide

Grosvenor

Grosvenor IT31 user guide

SS Telecoms SS-68BB user manual

SS Telecoms

SS Telecoms SS-68BB user manual

X2E XORAYA Z7 user manual

X2E

X2E XORAYA Z7 user manual

beadedstream D605 Installation & quick start guide

beadedstream

beadedstream D605 Installation & quick start guide

Marathon EDL-4S quick start guide

Marathon

Marathon EDL-4S quick start guide

infoAgro THI operating instructions

infoAgro

infoAgro THI operating instructions

METER ZL6 Replacement

METER

METER ZL6 Replacement

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.