manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. MadgeTech
  6. •
  7. Data Logger
  8. •
  9. MadgeTech VFC2000-MT Specification sheet

MadgeTech VFC2000-MT Specification sheet

VFC2000-MT
VFC Temperature Data Logger
PRODUCT
USER GUIDE
TABLE OF CONTENTS
2Product Overview
2Device Operation
3Device Maintenance
3Need Help?
4Specifications
4Ordering Information
To view the full MadgeTech product line, visit our
website at madgetech.com.
Product User Guide | 2
VFC2000-MT
PRODUCT USER GUIDE
Product Overview
The VFC2000-MT is a simple solution for vaccine
temperature monitoring compliance. Designed to satisfy
all CDC and VFC requirements, the VFC2000-MT provides
precise, continuous temperature monitoring and validation
for temperatures as low as -100 °C (-148 °F). Featuring a
convenient LCD screen, the VFC2000-MT displays current
readings, minimum and maximum statistics as well as a
battery level indicator. User-programmable alarms trigger
an audible and visual alert. Optional glycol bottle monitors
for temperatures as low as -50 °C (-58 °F) and AC power
source allows battery to be a back up if there is a power loss.
VFC Requirements
• Detachable, buered temperature probe
• Out-of-range audible and visual alarms
• Low battery indicator with external power and battery
backup
• Current, minimum, and maximum temperature display
• Accuracy of ±0.5°C (±1.0°F)
• Programmable logging interval (1 reading per second
to 1 reading per day)
• Daily check reminder warning
• Suitable for vaccine transportation
• Also monitors ambient room temperature
Device Operation
1. Install the MadgeTech 4 Software onto a Windows PC.
2. Connect the data logger to the Windows PC with the
provided USB cable.
3. Launch the MadgeTech 4 Software. The VFC2000-MT
will appear in the Connected Devices window
indicating the device has been recognized.
4. Select the start method, reading interval and any other
parameters appropriate for the desired data logging
application. Once configured, deploy the data logger by
clicking the Start icon.
5. To download data, select the device in the list, click the
Stop icon, and then click the Download icon. A graph
will automatically display the data.
Selection Buttons
The VFC2000-MT is designed with three selection buttons:
Scroll: Allows user to scroll through
current readings, average stats, daily
minimum and maximum temperatures
and device status information displayed on
the LCD screen.
°C
°F
Units: Allows users to change displayed
units of measurement to either Celsius or
Fahrenheit.
Start/Stop: To activate Manual Start,
arm the device through the MadgeTech 4
Software. Hold the button for 3 seconds.
There will be two beeps confirming the
device is started. Reading will be displayed
on the screen and status in software will
change from Waiting to Start to Running.
To pause logging while running, hold
button for 3 seconds.
LED Indicators
Status: Green LED blinks every 5 seconds
to indicate the device is logging.
Check: Blue LED blinks every 30 seconds to
indicate daily statistic check has gone past
24 hours. Hold Scroll button for 3 seconds to
reset reminder.
Alarm: Red LED blinks every 1 second to
indicate an alarm condition is set.
Product User Guide | 3
VFC2000-MT
PRODUCT USER GUIDE
Recalibration
Recalibration is recommended annually or bi-annually for
any data logger; a reminder is automatically displayed in
the software when the device is due. To send devices back
for calibration, visit madgetech.com.
Device Maintenance
Battery Replacement
Materials: U9VL-J Battery or any 9 V Battery (lithium
recommended)
1. On the bottom of the data logger, open the battery
compartment by pulling in on the cover tab.
2. Remove the battery by pulling it from the
compartment.
3. Install the new battery, taking note of the polarity.
4. Push the cover closed until it clicks.
Product Support & Troubleshooting:
• Refer to the Troubleshooting section of this document.
• Visit our Knowledge Base online at madgetech.com/resources.
• Contact our friendly Customer Support Team at (603) 456-2011 or support@madgetech.com.
MadgeTech 4 Software Support:
• Refer to the built-in help section of the MadgeTech 4 Software.
• Download the MadgeTech 4 Software Manual at madgetech.com.
• Contact our friendly Customer Support Team at (603) 456-2011 or support@madgetech.com.
VFC2000-MT
DOC-1410036-00 | REV 3 2021.11.08
PRODUCT USER GUIDE
6 Warner Road, Warner, NH 03278
(603) 456-2011
info@madgetech.com
madgetech.com
Specifications
Specifications are subject to change without notice. Specific warranty remedy limitations apply. Call (603) 456-2011 or go to madgetech.com for details.
TEMPERATURE
Temperature Range -20 °C to +60 °C (-4 °F to +140 °F)
Resolution 0.01 °C (0.018 °F)
Calibrated Accuracy ±0.50 °C/± 0.18 °F
(0 °C to +55 °C/32 °F to 131 °F)
Response Time 10 minutes free air
REMOTE CHANNEL
Thermocouple
Connection
Female subminiature (SMP) (MP model)
Pluggable screw terminal (TB model)
Cold Junction
Compensation Automatic, based on internal channel
Max. Thermocouple
Resistance 100 Ω
Thermocouple K
Included Probe Range: -100 °C to +80 °C
(-148 °F to +176 °F)
Glycol Bottle Range: -50 °C to +80 °C
(-58 °F to +176 °F)
Resolution: 0.1 °C
Accuracy: ±0.5 °C
Response Time τ= 2 minutes to 63% of change
GENERAL
Reading Rate 1 reading every second up to 1 reading every
24 hours
Memory 16,128 readings
LED
Functionality 3 status LEDs
Wrap Around Yes
Start Modes Immediate and delay start
Calibration Digital calibration through soware
Calibration Date Automatically recorded within device
Battery Type 9 V lithium battery included; user replaceable
with any 9 V battery (lithium recommended)
Battery Life 3 years typical at 1 minute reading rate
Data Format For Display: °C or °F
For Soware: Date and time stamped °C, K, °F or °R
Time Accuracy ± 1 minute/month
Computer
Interface
USB to mini USB, 250,000 baud for standalone
operation
Operating
System
Compatibility
Windows XP SP3 or later
Soware
Compatibility Standard Soware version 4.2.21.0 or later
Operating
Environment
-20 °C to +60 °C (-4 °F to +140 °F),
0 %RH to 95 %RH non-condensing
Dimensions 3.0 in x 3.5 in x 0.95 in
(76.2 mm x 88.9 mm x 24.1 mm) Data logger only
Glycol Bottle 30 mL
Probe Length 72 in
Material ABS Plastic
Weight 4.5 oz (129 g)
Approvals CE
Alarm
User configurable high and low audible and on-
screen alarms.
Alarm Delay: A cumulative alarm delay may be
set in which the device will activate the alarm (via
LED) only when the device has recorded a user
specified time duration of data.
Audible Alarm
Functionality
1 Beep per second for reading alarm above/
below threshold
BATTERY WARNING: BATTERY MAY LEAK, FLAME OR EXPLODE IF DISASSEMBLED, SHORTED, CHARGED, CONNECTED TOGETHER, MIXED WITH USED OR OTHER BATTERIES, EXPOSED
TO FIRE OR HIGH TEMPERATURE. DISCARD USED BATTERY PROMPTLY. KEEP OUT OF REACH OF CHILDREN.
Ordering Information
VFC2000-MT PN 902311-00 VFC Temperature data logger with thermocouple probe and USB to mini USB cable
VFC2000-MT-GB PN 902238-00 VFC Temperature data logger with thermocouple probe, glycol bottle and USB to mini USB cable
Power Adapter PN 901839-00 Replacement USB universal power adapter
U9VL-J PN 901804-00 Replacement battery for VFC2000-MT

Other MadgeTech Data Logger manuals

MadgeTech Temp1000IS Specification sheet

MadgeTech

MadgeTech Temp1000IS Specification sheet

MadgeTech State101A Specification sheet

MadgeTech

MadgeTech State101A Specification sheet

MadgeTech Process101A 20mA Specification sheet

MadgeTech

MadgeTech Process101A 20mA Specification sheet

MadgeTech RFOT User manual

MadgeTech

MadgeTech RFOT User manual

MadgeTech Volt101A-2.5V Specification sheet

MadgeTech

MadgeTech Volt101A-2.5V Specification sheet

MadgeTech HiTemp140 Series Specification sheet

MadgeTech

MadgeTech HiTemp140 Series Specification sheet

MadgeTech QuadTemp2000 User manual

MadgeTech

MadgeTech QuadTemp2000 User manual

MadgeTech PRHTemp2000 User manual

MadgeTech

MadgeTech PRHTemp2000 User manual

MadgeTech RFCO2RHTemp2000A Specification sheet

MadgeTech

MadgeTech RFCO2RHTemp2000A Specification sheet

MadgeTech QuadVolt-100mV User manual

MadgeTech

MadgeTech QuadVolt-100mV User manual

MadgeTech RFOT Specification sheet

MadgeTech

MadgeTech RFOT Specification sheet

MadgeTech Shock101-EB-5 User manual

MadgeTech

MadgeTech Shock101-EB-5 User manual

MadgeTech HiTemp140-FP User manual

MadgeTech

MadgeTech HiTemp140-FP User manual

MadgeTech QuadTemp2000 User manual

MadgeTech

MadgeTech QuadTemp2000 User manual

MadgeTech HiTemp140-FP Specification sheet

MadgeTech

MadgeTech HiTemp140-FP Specification sheet

MadgeTech EggTemp-RH Specification sheet

MadgeTech

MadgeTech EggTemp-RH Specification sheet

MadgeTech Temp1000P User manual

MadgeTech

MadgeTech Temp1000P User manual

MadgeTech RFC1000 User manual

MadgeTech

MadgeTech RFC1000 User manual

MadgeTech PR2000 User manual

MadgeTech

MadgeTech PR2000 User manual

MadgeTech HiTemp140-FR Specification sheet

MadgeTech

MadgeTech HiTemp140-FR Specification sheet

MadgeTech Logicbus X Series Specification sheet

MadgeTech

MadgeTech Logicbus X Series Specification sheet

MadgeTech pHTemp2000 User manual

MadgeTech

MadgeTech pHTemp2000 User manual

MadgeTech PR2009 Specification sheet

MadgeTech

MadgeTech PR2009 Specification sheet

MadgeTech TempRetriever User manual

MadgeTech

MadgeTech TempRetriever User manual

Popular Data Logger manuals by other brands

Velleman Instruments PCS10 manual

Velleman Instruments

Velleman Instruments PCS10 manual

Campbell Aspen 10 Getting started guide

Campbell

Campbell Aspen 10 Getting started guide

TESTO 174 instruction manual

TESTO

TESTO 174 instruction manual

Convergence Instruments NSRTW mk3 user manual

Convergence Instruments

Convergence Instruments NSRTW mk3 user manual

Measurement Computing USB-2416-4AO user guide

Measurement Computing

Measurement Computing USB-2416-4AO user guide

3nStar Nustar 5sx user manual

3nStar

3nStar Nustar 5sx user manual

Neptune Technology E-Coder)R900i Installation and maintenance guide

Neptune Technology

Neptune Technology E-Coder)R900i Installation and maintenance guide

ALAT UJI TM-7 Series user manual

ALAT UJI

ALAT UJI TM-7 Series user manual

Seneca MyALARM2 quick start guide

Seneca

Seneca MyALARM2 quick start guide

Signatrol SL7000 Series user guide

Signatrol

Signatrol SL7000 Series user guide

Addi-Data MSX-ilog Series Technical description

Addi-Data

Addi-Data MSX-ilog Series Technical description

Hoymiles DTU-MI-GPRS user manual

Hoymiles

Hoymiles DTU-MI-GPRS user manual

NeuLog NUL-233 Guide

NeuLog

NeuLog NUL-233 Guide

ABB VSN300 product manual

ABB

ABB VSN300 product manual

MRC MHT-381SD Operation manual

MRC

MRC MHT-381SD Operation manual

Sungrow Logger4000 user manual

Sungrow

Sungrow Logger4000 user manual

Teac WX-7000 owner's manual

Teac

Teac WX-7000 owner's manual

ikeGPS IKE 4 Setup guide

ikeGPS

ikeGPS IKE 4 Setup guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.