Description
This pr oduct u ses inf rar ed indu ction p rinciple c an be fas t, accu rate
tempe ratur e measu rem ent of th e amoun t that can qui ckly se lecte d
from a la rge pop ulati on th e highe r tempe rature
• Autom atic te mpera tur e compe nsati on.
• Range :32°C ~42°C
• Autom atic st orage 1 0 gro ups dat a
• °C/°F S elect able
01 02
03
04 05
PA N EL
Display
• Pleas e read th e follo win g infor matio n carefull y befor e using t he
meter.
• the bod y tempe ratur e mea surem ent for r eference o nly,
shall n ot be use d as the ba sis f or medi cal pra ctices to de termi ne
if have a bnorm al temp era ture, m ake fur ther use of me dical
therm omete r measurem ents
• Measu remen t dista nce : 5 ~15cm .
• When th e batte ry symbol ap pears , it indi cates that w e must
chang e the bat tery
Warning
1. Sereen
2. Mode key
3. Backlit
4. Mem key
5. °C/°F Switch
6. Sensor
7. Tirger
8. Battery cover
11
10
9
8
7
6
5
4
3
21
1
2
3
4
5
6
7
8
1. Low battery
2. Forhead mode
3. °C unit
4. °F unit
Alarm function
5. Secondary display
6. Mem index
7. Mem function
8. Primary display
Hold mode
Scan mode
1
2
3
4
6
7
8
9
510
11
Operatoring thermometer
• To measur e Body te mpera tur e, the me asuri ng distanc e
5 ~ 15cm; p ress th e trigger st art mea surin g, approx 1s , the
meter s ound pr ompts to mea surem ent com plete.wh en the
tempe ratur e highe r 42 °C o r lower 3 2 °C the me ter displa y
'Hi','LO '.
• The met er turn s off w hen no ac tivity is de tecte d for ten s eco nds.
• Press k ey to lig ht on or off the b acklight .
• Press k ey to ent er alarm or te mpera ture ad just funct ion.
• Press k ey to swi tch betwee n °C or °F.
• Press M EM key to a ctive memo ry func tion.
.
• Press ' MEM' key to ac tive memor y funct ion ,in m emory mode ,the
meter d ispla y 'MEM'.
• When me mory fu nctio n is ac tived , after t he measure ment
compl eted ,t he meter wil l autom atic re cord the dat a.
• Recor d up to 10 gr oups of t he la st meas ureme nt data, ser ial
numbe r from 0 to 9 , when the sto red num ber is gr eater than 9
meter s autom atically s tore th e numbe r 0 from the sto re.
• Press k ey to pag e up.
• Press k ey to pag e down
Memory function
08 09 1 006 07 11
HYS006764
1
2
3
4
Alarm function
1. Unit
2. Alarm indicator
1
2
3
4
Alarm function status
Alarm value
• Press k ey swit ch to alarm fu nctio n statu s.
• Press M EM key to t urn on or off al arm functi on; the n alarm
funct ion be tu rn on, the AL sign wil l be disp lay ed in sca n mode .
• Press k ey to inc rease the al arm val ue.
• Press k ey to dec rease the al arm val ue.
• Press k ey to sav e and exit ala rm func tion st atus .
Temperature adjust
1
2
3
1. Unit
2. Temperature adjust status
1
2
3Temperature adjust value
• Press k ey swit ch to temper ature a djust s tatus.
• Press k ey to inc rease adju st valu e.
• Press k ey to dec rease adju st valu e.
• Press k ey to sav e and exit tem perat ure adj ust status .
12
6
3
9
30Min
22 C°
72 F°
0 C°
32 F°
Note 1:
When ambien t temperatu re changes qu ickly, must wait
30 minutes to b alance the te mperature o f the instrum ent
before use.
Note 2:
When the batt ery voltage i s lower, the bat tery symbol
appears, it i ndicates th at we must chan ge the batter y.
Specifications
Temperature range 32°C~42°C
(89°F~108°F)
Certifications CE
Accuracy:Assumes
ambient operating
temperature
(23°C ±2°C)
32~42°C
(±0.4°C)
Spectral
response
8-14 um
Measurement
distance 5~15cm Response
time approx1s
Repeatability 0.1°C Dimensions 142×92×47mm
Ambient Operating
Range
Relative humidity
Standards
0.1°C/0.2°F
Conforms to EN61326/EN61010-1
Weight 135g
Resolution
15°C~35°C Power 9V 6F22
10%~90%
Warranty
This produt w ill be free fro m defects in ma terial and
workmansh ip for eighte en months fro m the date of
purchase. t his warrant y does not cove r disposabl e
batteries o r damage for ac cident,ne glect,mis use
alteratio n conntamin ation,or ab normal cond itions
of operatio n ro handling .
11

Other Mastech Thermometer manuals

Mastech MS6530 User manual

Mastech

Mastech MS6530 User manual

Mastech MS6520A User manual

Mastech

Mastech MS6520A User manual

Mastech MS6500 User manual

Mastech

Mastech MS6500 User manual

Mastech MS6520B User manual

Mastech

Mastech MS6520B User manual

Mastech MS6550A User manual

Mastech

Mastech MS6550A User manual

Mastech MS6530T User manual

Mastech

Mastech MS6530T User manual

Mastech MS6511 SERIES User manual

Mastech

Mastech MS6511 SERIES User manual

Mastech MS6550B User manual

Mastech

Mastech MS6550B User manual

Mastech MS6522B User manual

Mastech

Mastech MS6522B User manual

Mastech MS6531ABC User manual

Mastech

Mastech MS6531ABC User manual

Mastech MS6501 User manual

Mastech

Mastech MS6501 User manual

Mastech MS6540A User manual

Mastech

Mastech MS6540A User manual

Mastech ms6520a User manual

Mastech

Mastech ms6520a User manual

Mastech EE-MS6501 Assembly instructions

Mastech

Mastech EE-MS6501 Assembly instructions

Mastech MS6530B User manual

Mastech

Mastech MS6530B User manual

Popular Thermometer manuals by other brands

SPX TIF3340 user manual

SPX

SPX TIF3340 user manual

Xavax 00111381 operating instructions

Xavax

Xavax 00111381 operating instructions

JUMO TDA-300 operating manual

JUMO

JUMO TDA-300 operating manual

Microlife MT 100 manual

Microlife

Microlife MT 100 manual

RND 365-00001 user manual

RND

RND 365-00001 user manual

Endress+Hauser iTHERM TrustSens TM371 Brief operating instructions

Endress+Hauser

Endress+Hauser iTHERM TrustSens TM371 Brief operating instructions

Comark C21 Operator's manual

Comark

Comark C21 Operator's manual

Napoleon ACCU-PROBE 70077 manual

Napoleon

Napoleon ACCU-PROBE 70077 manual

TESTO 104 instruction manual

TESTO

TESTO 104 instruction manual

Dr. Trust FR200 user manual

Dr. Trust

Dr. Trust FR200 user manual

Sanitas SFT 08 user manual

Sanitas

Sanitas SFT 08 user manual

Mobiclinic TPF-01 instructions

Mobiclinic

Mobiclinic TPF-01 instructions

Extech Instruments 445703 user manual

Extech Instruments

Extech Instruments 445703 user manual

Munchkin 38111 owner's guide

Munchkin

Munchkin 38111 owner's guide

General IRT675 user manual

General

General IRT675 user manual

General IRT205 user manual

General

General IRT205 user manual

LIMIT 13955-0107 manual

LIMIT

LIMIT 13955-0107 manual

Braun ThermoScan IRT 6515 manual

Braun

Braun ThermoScan IRT 6515 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.